3.1 General information

Version 1.67 by Admin on 2025/01/29 17:24

Configuration

General information

List of input signals

Here is the list of available input signals of BMS Main 3.

NameDescriptionUsed bySet up by
Discrete inputCANModbus
Battery cover  a signal from the battery cover;Battery cover protection  
Charger connected  a signal indicating that charger is connected;Charge controller, Discharge controller• (if corresponding External equipment is online) 
Power up/down request  a request to power down the device;Power down controller  
Inhibit charging  a command to open the charging contactor;   
Inhibit discharging  a command to open the discharging contactor;   
CH contactor feedback  a signal from charging contactor feedback loop;Contactor feedback protection  
DCH contactor feedback  a signal from discharging contactor feedback loop;Contactor feedback protection  
Insulation status  a signal from an insulation monitoring device;Insulation protection  
Charge request  a request to close the charging contactor;Charge controller• (by request) 
Discharge request  a request to close the discharging contactor;Discharge controller• (by request) 
PCH contactor feedback  a signal from precharging contactor feedback loop;Contactor feedback protection  
CH/DCH contactor feedback  a signal from charging/discharging contactor feedback loop;Contactor feedback protection  
Main contactor feedback  a signal from main contactor feedback loop;Contactor feedback protection  
Interlock  a signal from interlock loop;Interlock protection  
Fuse 1, Fuse 2, Fuse 3  signals from fuses;   
Circuit breaker status  status of protection disconnector;   
Balancing request  a request to balance the cells;Cell balance controller 
Close Main contactor  a request to close the main contactor;Main contactor controller• (by request) 
Close External 1  a request to close the External 1 discrete output (if assigned).External 1 internal state  

List of internal states

Here is the list of available internal states of BMS Main 3.

NameDescriptionSet up byUsed byOutput by
Discrete outputSwitchCANModbus
Low SOC  a signal corresponding the low SOC of the battery;Low SOC signal controller   
High charging current  charging current is high;High charging signal controller   
Main contactor  state of the main contactor;Main contactor controller   
Charging  state of the charging contactor;Charge controller, Charge/Discharge controller   
Allow charging  a signal for a charger to start charging;Charge controller, Charge/Discharge controller   
Charging current present  the presence of the charging current;Charging status controller   
Precharging  state of the precharging contactor;Precharge controller   
Discharging  state of the discharging contactor;Discharge controller, Charge/Discharge controller   
Discharging current present  the presence of the discharging current;Discharging status controller   
Discharging (AUX)  state of the auxiliary discharging contactor;Discharging (AUX) controller   
Power down ACK  an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;Power down controller   
Charging/dischargingstate of the charging/discharging contactor;Charge/Discharge controller   
Heater  a command to turn on a heater;Heater controller   
Cooler  a command to turn on a cooler;Cooler controller   
Balancing 1  balancing the first series of cells;Series balancing controller   
Balancing 2  balancing the second series of cells;Series balancing controller   
Ready to charge  the battery is ready to be charged;Charging status controllerCharge controller  
Ready to discharge  the battery is ready to be discharged;Discharging status controllerDischarge controller  
Power up  an indication of BMS power status;    
General error  state of the configurable (general) error;General error protection     
External 1  a signal that activates by the remote request.External 1 input signal     

List of errors

Here is the list of error of BMS Main 3.