Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,8 +6,6 @@ 6 6 7 7 === List of input signals === 8 8 9 -Here is the list of available input signals of BMS Main 3. 10 - 11 11 (% style="width:1274px" %) 12 12 |=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 60px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 483px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 248px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 143px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**Modbus** 13 13 |=(% style="width: 98px;" %)**Mini S / Mini**|=(% style="width: 77px;" %)**Main 2.1**|=(% style="width: 81px;" %)**Main 3** ... ... @@ -35,8 +35,6 @@ 35 35 36 36 === List of internal states === 37 37 38 -Here is the list of available internal states of BMS Main 3. 39 - 40 40 (% style="width:1277px" %) 41 41 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 42 42 |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** ... ... @@ -70,60 +70,58 @@ 70 70 71 71 === List of errors === 72 72 73 -Here is the list of error of BMS Main 3. 74 - 75 75 (% style="width:1279px" %) 76 76 |(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:58px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="3" rowspan="1" style="width:248px" %)**Compability**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus** 77 77 |=(% style="width: 93px;" %)**Mini S / Mini**|=(% style="width: 76px;" %)**Main 2.1**|=(% style="width: 80px;" %)**Main 3** 78 -| (%style="width:196px" %)Overcurrent|(%style="width:58px"%)OC|(% style="width:443px"%) |(% style="width:67px" %) |(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)79 -| (% style="width:196px" %)Undervoltage|(%style="width:58px"%)UV|(% style="width:443px" %)|(% style="width:67px" %) |(% style="width:93px"%)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)80 -| (%style="width:196px"%)Overvoltage|(%style="width:58px"%)OV|(% style="width:443px"%) |(%style="width:67px"%) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)81 -| (%style="width:196px"%)Low temperature(DCH)|(%style="width:58px" %)LDT|(% style="width:443px"%)temperatureis too lowfordischarging;|(%style="width:67px"%) |(%style="width:93px"%)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)82 -| (% style="width:196px" %)Hightemperature(DCH) |(% style="width:58px" %)HDT|(% style="width:443px"%)temperatureistoohighfordischarging;|(%style="width:67px"%)|(% style="width:93px" %)Yes|(%style="width:76px"%)Yes|(% style="width:80px"%)Yes|(% style="width:142px" %) |(% style="width:134px" %)83 -| (%style="width:196px" %)Batterycovererror |(% style="width:58px" %)BC|(% style="width:443px" %)batterycover is open;|(%style="width:67px"%)•|(% style="width:93px" %)Yes|(%style="width:76px"%)Yes|(% style="width:80px"%)Yes|(% style="width:142px" %) |(% style="width:134px" %)84 -| (% style="width:196px" %)High humidity|(% style="width:58px"%)HH|(% style="width:443px"%)humidityofhebatteryisincreased;|(%style="width:67px" %)|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)85 -| (% style="width:196px" %)Water|(% style="width:58px" %)WA|(% style="width:443px"%)thereiswaterinthebatteryenclosure;|(%style="width:67px"%)•|(% style="width:93px"%)Yes|(%style="width:76px"%)Yes|(%style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)86 -| (% style="width:196px" %)High Logictemperature |(% style="width:58px"%)LHT|(% style="width:443px" %)at leastone of the Logic devices is overheated;|(%style="width:67px" %)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)87 -| (% style="width:196px"%)Logicoffline|(% style="width:58px"%)LOF|(% style="width:443px"%)atleastoneofheLogic devicesis offline;|(%style="width:67px" %)•|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)88 -| (% style="width:196px"%)Criticalerror|(%style="width:58px" %)CER|(%style="width:443px"%)|(%style="width:67px"%) |(% style="width:93px"%)Yes|(%style="width:76px"%)Yes|(%style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)89 -| (% style="width:196px"%)Crown error |(% style="width:58px" %)CRO|(% style="width:443px" %)connectionwitha Crownforkliftis lost;|(% style="width:67px" %)|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)90 -| (% style="width:196px" %)Cellcount error |(% style="width:58px" %)CEL|(%style="width:443px" %)numberofcellsdoesmatchthespecified value;|(%style="width:67px" %)•|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)91 -| (%style="width:196px" %)HYGoffline|(% style="width:58px"%)HYG|(%style="width:443px"%)connectionwithaHYGforklift islost;|(% style="width:67px"%) |(% style="width:93px"%)Yes|(% style="width:76px"%)Yes|(%style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)92 -| (%style="width:196px" %)Need acknowledge |(% style="width:58px" %)ACK|(% style="width:443px" %)there is an unacknowledged errorinError journal;|(%style="width:67px" %)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)93 -| (% style="width:196px" %)Combilift offline|(% style="width:58px" %)COM|(% style="width:443px" %)connection withaCombiliftforklift is lost;|(%style="width:67px" %)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)94 -| (% style="width:196px"%)Shortircuit|(%style="width:58px" %)SHC|(% style="width:443px" %)|(%style="width:67px" %)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)95 -| (% style="width:196px" %)Highcontactor temperature|(% style="width:58px"%)CHT|(% style="width:443px"%)|(% style="width:67px"%) |(% style="width:93px"%)Yes|(% style="width:76px"%)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)96 -| (% style="width:196px"%)Logiccountror|(% style="width:58px"%)LOG|(% style="width:443px"%)|(%style="width:67px"%) |(% style="width:93px"%) |(%style="width:76px" %)|(%style="width:80px" %)|(% style="width:142px" %) |(% style="width:134px" %)97 -| (%style="width:196px" %)ADCerror |(% style="width:58px"%)ADC|(% style="width:443px" %)current cannotbe measured;|(%style="width:67px"%)•|(%style="width:93px"%)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)98 -| (% style="width:196px"%)Currentsensorerror |(% style="width:58px"%)CSE|(%style="width:443px" %)errorinthecurrent sensorcircuit;|(%style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)99 -| (% style="width:196px"%)CH contactor cycleserror |(% style="width:58px"%)CCC|(% style="width:443px"%)switchingfrequencyofthecharging contactorstoo high;|(% style="width:67px" %)|(%style="width:93px" %)Yes|(%style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)100 -| (% style="width:196px" %)DCHcontactor cycles error |(% style="width:58px" %)DCC|(% style="width:443px" %)switchingfrequencyofthe dischargingcontactoris toohigh;|(% style="width:67px" %)|(%style="width:93px" %)Yes|(%style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)101 -| (%style="width:196px" %)Shuntoffline |(% style="width:58px" %)SHO|(% style="width:443px" %)connection withtheshuntcurrentsensoris lost;|(%style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)102 -| (% style="width:196px" %)Shunt error |(%style="width:58px" %)SHE|(% style="width:443px" %)internalerror ofthe shuntcurrent sensor;|(%style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)103 -| (% style="width:196px"%)Settingserror|(% style="width:58px" %)SET|(%style="width:443px" %)|(%style="width:67px" %)|(%style="width:93px" %)|(%style="width:76px" %)|(%style="width:80px" %)|(% style="width:142px" %) |(% style="width:134px" %)104 -| (%style="width:196px" %)WDT reset|(% style="width:58px" %)WDT|(% style="width:443px" %)watchdogtimerresetthe device;|(%style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)105 -| (% style="width:196px"%)Notemperaturesensors |(% style="width:58px" %)NTS|(% style="width:443px" %)the device has no temperature sensorsconnected;|(%style="width:67px"%)•|(%style="width:93px"%)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)106 -| (%style="width:196px" %)Temperaturesensor is shorted |(% style="width:58px" %)TSS|(% style="width:443px" %)some temperature sensorsareshorted;|(%style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)107 -| (%style="width:196px" %)Spiritoffline|(% style="width:58px"%)SPI|(%style="width:443px"%)connectionwithaSpiritforklift islost;|(% style="width:67px"%) |(% style="width:93px"%)Yes|(% style="width:76px"%)Yes|(%style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)108 -| (% style="width:196px" %)Mount error|(% style="width:58px" %)MNT|(%style="width:443px" %)|(%style="width:67px" %)|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)109 -| (%style="width:196px" %)FSerror|(% style="width:58px"%)FSE|(%style="width:443px"%) |(% style="width:67px"%)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)110 -| (% style="width:196px" %)Lowtemperature(CH) |(%style="width:58px"%)LCT|(% style="width:443px"%)temperatureistoo low for charging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)111 -| (% style="width:196px" %)High temperature(CH) |(% style="width:58px" %)HCT|(%style="width:443px" %)temperature is too high for charging;|(%style="width:67px" %)|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)112 -| (% style="width:196px" %)Unallowable charging |(% style="width:58px" %)UCH|(% style="width:443px" %)charging thebattery through the discharging contactor;|(%style="width:67px" %)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)113 -| (%style="width:196px" %)Stuck contactor|(%style="width:58px"%)STC|(% style="width:443px"%) |(% style="width:67px"%)•|(%style="width:93px" %)Yes|(%style="width:76px" %)Yes|(%style="width:80px"%)Yes|(% style="width:142px" %) |(% style="width:134px" %)114 -| (% style="width:196px"%)CH contactorfeedbackerror|(%style="width:58px" %)CCF|(% style="width:443px"%)thecontrolsignalsforthechargingcontactorandthecontactorfeedbackdiffer;|(% style="width:67px" %)•|(%style="width:93px" %)|(%style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %)115 -| (%style="width:196px"%)DCH contactor feedback error |(% style="width:58px" %)DCF|(%style="width:443px" %)the controlsignals forhedischargingcontactorandthecontactorfeedback differ;|(%style="width:67px"%)•|(% style="width:93px" %) |(% style="width:76px"%)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %)116 -| (% style="width:196px" %)Insulationfault;|(%style="width:58px"%)INF|(% style="width:443px"%) |(% style="width:67px"%)•|(%style="width:93px"%)Yes|(% style="width:76px"%)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)117 -| (% style="width:196px" %)PCH contactor feedback error |(% style="width:58px" %)PCF|(% style="width:443px" %)the control signalsfor theprecharging contactorand the contactor feedback differ;|(%style="width:67px" %)•|(%style="width:93px" %)|(%style="width:76px" %)Yes|(%style="width:80px" %)|(% style="width:142px" %) |(% style="width:134px" %)118 -| (% style="width:196px" %)CH/DCH contactorfeedback error |(% style="width:58px"%)CDF|(% style="width:443px" %)thecontrol signals forthecharging/discharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(%style="width:93px" %)|(%style="width:76px" %)Yes|(%style="width:80px" %)|(% style="width:142px" %) |(% style="width:134px" %)119 -| (% style="width:196px" %)Maincontactorfeedback error |(% style="width:58px" %)MCF|(% style="width:443px" %)the control signalsfor themain contactorandthecontactorfeedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(%style="width:76px" %)Yes|(% style="width:80px" %)|(% style="width:142px" %) |(% style="width:134px" %)120 -| (% style="width:196px"%)Contactorfeedback error|(% style="width:58px"%)CFE|(% style="width:443px" %)Failureof one ofthecontactorsfeedbacksignal. Which contactor isfailed can be |(%style="width:67px" %)|(% style="width:93px" %)Yes|(% style="width:76px" %) |(%style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)121 -| (% style="width:196px"%)Generalerror|(%style="width:58px"%)GE|(%style="width:443px"%) |(% style="width:67px"%)|(%style="width:93px"%)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)122 -| (% style="width:196px" %)High voltage fault|(% style="width:58px" %)HVF|(% style="width:443px" %)failureof high voltage measuringcircuits;|(%style="width:67px" %)•|(% style="width:93px" %) |(%style="width:76px" %)|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)123 -| (% style="width:196px" %)Powerswitcherror|(%style="width:58px"%)PSE|(%style="width:443px" %)short circuit in contactorcoil control circuitorpowerswitchverheating;|(% style="width:67px" %)•|(% style="width:93px" %) |(%style="width:76px" %)|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)124 -| (% style="width:196px" %)HVIL error |(% style="width:58px"%)HE|(%style="width:443px"%)breakage ofhigh-voltageinterlockcurrentloop;|(%style="width:67px" %)•|(% style="width:93px" %) |(%style="width:76px" %)|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)125 -| (% style="width:196px" %)Precharge error |(% style="width:58px" %)PE|(% style="width:443px" %)capacitive load pre-chargeprocess did not end during the estimated time;|(%style="width:67px" %)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)126 -| (% style="width:196px" %)Powerfault|(% style="width:58px" %)PF|(% style="width:443px" %)external devicespower supply error: currentsensors,HVIL, BMS Logic or CAN2 (int)bus powereddevices;|(% style="width:67px" %)•|(% style="width:93px" %) |(%style="width:76px" %)|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)127 -| (%style="width:196px" %)Current limit error |(%style="width:58px"%)CLE|(% style="width:443px" %)chargingor dischargingcurrent ismorehanlimitcalculated by Chargemap or Dischargemap.|(% style="width:67px" %)|(% style="width:93px" %)Yes|(% style="width:76px" %) |(%style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)72 +|ADC error |ADC|current cannot be measured;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 73 +|Battery cover error |BC|battery cover is open;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 74 +|Cell count error |CEL|number of cells does not match the specified value;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 75 +|CH contactor cycles error |CCC|switching frequency of the charging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 76 +|CH contactor feedback error |CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %) 77 +|CH/DCH contactor feedback error |CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %) 78 +|Combilift offline |COM|connection with a Combilift forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 79 +|Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be | |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %) 80 +|Critical error|CER| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 81 +|Crown error |CRO|connection with a Crown forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 82 +|Current limit error |CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %) 83 +|Current sensor error |CSE|error in the current sensor circuit;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 84 +|DCH contactor cycles error |DCC|switching frequency of the discharging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 85 +|DCH contactor feedback error |DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %) 86 +|FS error|FSE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 87 +|General error|GE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 88 +|High contactor temperature|CHT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 89 +|High humidity |HH|humidity of the battery is increased;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 90 +|High Logic temperature |LHT|at least one of the Logic devices is overheated;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 91 +|High temperature (CH) |HCT|temperature is too high for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 92 +|High temperature (DCH) |HDT|temperature is too high for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 93 +|High voltage fault |HVF|failure of high voltage measuring circuits;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 94 +|HVIL error |HE|breakage of high-voltage interlock current loop;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 95 +|HYG offline |HYG|connection with a HYG forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 96 +|Insulation fault;|INF| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 97 +|Logic count error|LOG| | | | | |(% style="width:142px" %) |(% style="width:134px" %) 98 +|Logic offline |LOF|at least one of the Logic devices is offline;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 99 +|Low temperature (CH) |LCT|temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 100 +|Low temperature (DCH) |LDT|temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 101 +|Main contactor feedback error |MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %) 102 +|Mount error|MNT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 103 +|Need acknowledge |ACK|there is an unacknowledged error in Error journal;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 104 +|No temperature sensors |NTS|the device has no temperature sensors connected;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 105 +|Overcurrent|OC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 106 +|Overvoltage|OV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 107 +|PCH contactor feedback error |PCF|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %) 108 +|Power fault |PF|external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 +|Power switch error |PSE|short circuit in contactor coil control circuit or power switch overheating;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 110 +|Precharge error |PE|capacitive load pre-charge process did not end during the estimated time;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 111 +|Settings error|SET| | | | | |(% style="width:142px" %) |(% style="width:134px" %) 112 +|Short circuit|SHC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 113 +|Shunt error |SHE|internal error of the shunt current sensor;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 114 +|Shunt offline |SHO|connection with the shunt current sensor is lost;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 115 +|Spirit offline |SPI|connection with a Spirit forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 116 +|Stuck contactor|STC| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 117 +|Temperature sensor is shorted |TSS|some temperature sensors are shorted;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 118 +|Unallowable charging |UCH|charging the battery through the discharging contactor;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 119 +|Undervoltage|UV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 120 +|Water |WA|there is water in the battery enclosure;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 121 +|WDT reset |WDT|watchdog timer reset the device;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 128 128 129 129