Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -39,15 +39,15 @@ 39 39 40 40 === List of internal states === 41 41 42 -Here is the list of internal states that can be assigned todiscreteoutput or relay42 +Here is the list of internal states used to control or communicate with other 43 43 44 44 (% style="width:1277px" %) 45 45 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 46 46 |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** 47 47 |Allow charging |ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 48 -|Balancing 1 |BA1|balancing the first series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 49 -|Balancing 2 |BA2|balancing the second series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 50 50 | | | | | | |(% style="width:140px" %) |(% style="width:142px" %) 49 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %) 50 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %) 51 51 |Charging current present |CCP|the presence of the charging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 52 52 |Charging |CH|state of the charging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 53 53 |Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) ... ... @@ -74,20 +74,22 @@ 74 74 | | | | | | |(% style="width:140px" %) |(% style="width:142px" %) 75 75 76 76 (% class="wikigeneratedid" %) 77 -Here is the list of indi cativeinternalstatesthat cannot be assigned to discrete output or relay.77 +Here is the list of internal states that are used just for information. They do not used to control or communicate with other devices and cannot be assigned to discrete output or relay. 78 78 79 79 (% style="width:1277px" %) 80 80 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 81 81 |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** 82 -| Init|INI| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)83 -| Shutdownrequest(HYG/Spirit)|HSH||Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)84 -| Voltagetoohighforcharging|ENV||Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)82 +|Crown EWS|EWS| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 83 +|Balancing 1 |BA1|balancing the first series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 84 +|Balancing 2 |BA2|balancing the second series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 85 85 |Cell analysis|CEA| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 86 86 |Shutdown request (Combilift)|CSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 87 +|Shutdown request (HYG/Spirit)|HSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 88 +|Voltage too high for charging|ENV| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 89 +|Init|INI| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 87 87 |Service reset|SR| |Yes| |Yes|(% style="width:140px" %) |(% style="width:142px" %) 88 -|Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 89 -|Cooler |COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 90 -|Crown EWS|EWS| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 91 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %) 92 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %) 91 91 92 92 === List of errors === 93 93