Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -39,6 +39,7 @@ 39 39 40 40 === List of internal states === 41 41 42 +Here is the list of internal states 42 42 43 43 (% style="width:1277px" %) 44 44 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** ... ... @@ -55,11 +55,11 @@ 55 55 |Discharging (AUX) |AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 56 56 |Discharging current present |DCP|the presence of the discharging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 57 57 |Discharging |DCH|state of the discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 58 -|External 1 |EX1|a signal that activates by the remote request.| 59 +|External 1 |EX1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 59 59 |Heater |HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 60 60 |Heater (AUX)|HA| | |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 61 61 |High charging current |HCC|charging current is high;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 62 -| Init|INI| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)63 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %) 63 63 |Low SOC |LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 64 64 |Main contactor |MCO|state of the main contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 65 65 |Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) ... ... @@ -69,12 +69,25 @@ 69 69 |Ready to discharge |RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 70 70 |Service reset|SR| |Yes| |Yes|(% style="width:140px" %) |(% style="width:142px" %) 71 71 |Shutdown request (Combilift)|CSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 72 -| Shutdownrequest(HYG/Spirit)|HSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)73 -| Voltagetoohighforcharging|ENV| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)73 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %) 74 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %) 74 74 75 75 (% class="wikigeneratedid" %) 76 - ~*States77 +Here is the list of indicative internal states that cannot be assigned to discrete output or relay. 77 77 79 +(% style="width:1277px" %) 80 +|=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 81 +|=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** 82 +|Init|INI| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 83 +|Shutdown request (HYG/Spirit)|HSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 84 +|Voltage too high for charging|ENV| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 85 +|Cell analysis|CEA| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 86 +|Charging current present |CCP|the presence of the charging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 87 +|Charging |CH|state of the charging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 88 +|Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 89 +|Cooler |COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 90 +|Crown EWS|EWS| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 91 + 78 78 === List of errors === 79 79 80 80 (% style="width:1279px" %)