Summary

Details

Page properties
Content
... ... @@ -6,120 +6,150 @@
6 6  
7 7  === List of input signals ===
8 8  
9 -Here is the list of available input signals of BMS Main 3.
9 +Here is the list of input signals that can be assigned to discrete inputs of BMS controller.
10 10  
11 -(% style="width:1274px" %)
12 -|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 60px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 483px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 248px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 143px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**Modbus**
13 -|=(% style="width: 98px;" %)**Mini S / Mini**|=(% style="width: 77px;" %)**Main 2.1**|=(% style="width: 81px;" %)**Main 3**
14 -|(% style="width:198px" %)Battery cover |(% style="width:60px" %)CVR|(% style="width:483px" %)a signal from the battery cover;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
15 -|(% style="width:198px" %)Charger connected |(% style="width:60px" %)CON|(% style="width:483px" %)a signal indicating that charger is connected;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
16 -|(% style="width:198px" %)Power up/down request |(% style="width:60px" %)PDN|(% style="width:483px" %)a request to power down the device;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
17 -|(% style="width:198px" %)Inhibit charging |(% style="width:60px" %)ICH|(% style="width:483px" %)a command to open the charging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
18 -|(% style="width:198px" %)Inhibit discharging |(% style="width:60px" %)IDC|(% style="width:483px" %)a command to open the discharging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
19 -|(% style="width:198px" %)CH contactor feedback |(% style="width:60px" %)CCF|(% style="width:483px" %)a signal from charging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
20 -|(% style="width:198px" %)DCH contactor feedback |(% style="width:60px" %)DCF|(% style="width:483px" %)a signal from discharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
21 -|(% style="width:198px" %)Insulation status |(% style="width:60px" %)INS|(% style="width:483px" %)a signal from an insulation monitoring device;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
22 -|(% style="width:198px" %)Charge request |(% style="width:60px" %)CRE|(% style="width:483px" %)a request to close the charging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
23 -|(% style="width:198px" %)Discharge request |(% style="width:60px" %)DRE|(% style="width:483px" %)a request to close the discharging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
24 -|(% style="width:198px" %)PCH contactor feedback |(% style="width:60px" %)PCF|(% style="width:483px" %)a signal from precharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
25 -|(% style="width:198px" %)CH/DCH contactor feedback |(% style="width:60px" %)CDF|(% style="width:483px" %)a signal from charging/discharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
26 -|(% style="width:198px" %)Main contactor feedback |(% style="width:60px" %)MCF|(% style="width:483px" %)a signal from main contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
27 -|(% style="width:198px" %)Interlock |(% style="width:60px" %) |(% style="width:483px" %)a signal from interlock loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
28 -|(% style="width:198px" %)Fuse 1|(% style="width:60px" %)F1|(% style="width:483px" %)signal from fuse 1;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
29 -|(% style="width:198px" %)Fuse 2|(% style="width:60px" %)F2|(% style="width:483px" %)signal from fuse 2;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
30 -|(% style="width:198px" %)Fuse 3 |(% style="width:60px" %)F3|(% style="width:483px" %)signal from fuse 3;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
31 -|(% style="width:198px" %)Circuit breaker status |(% style="width:60px" %)CBS|(% style="width:483px" %)status of protection disconnector;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
32 -|(% style="width:198px" %)Balancing request |(% style="width:60px" %)BR|(% style="width:483px" %)a request to balance the cells;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
33 -|(% style="width:198px" %)Close Main contactor |(% style="width:60px" %)CMC|(% style="width:483px" %)a request to close the main contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
34 -|(% style="width:198px" %)Close External 1 |(% style="width:60px" %)CE1|(% style="width:483px" %)a request to close the External 1 discrete output (if assigned).|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
11 +(% style="width:1278px" %)
12 +|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 60px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 500px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 243px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**Modbus**
13 +|=(% style="width: 92px;" %)**Mini S / Mini**|=(% style="width: 73px;" %)**Main 2.1**|=(% style="width: 78px;" %)**Main 3**
14 +|Balancing request |BR|(% style="width:500px" %)a request to balance the cells;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
15 +|Battery cover |CVR|(% style="width:500px" %)a signal from the battery cover;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
16 +|CH contactor feedback |CCF|(% style="width:500px" %)a signal from charging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
17 +|CH/DCH contactor feedback |CDF|(% style="width:500px" %)a signal from charging/discharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
18 +|Charge request |CRE|(% style="width:500px" %)a request to close the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
19 +|Charger connected |CON|(% style="width:500px" %)a signal indicating that charger is connected;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
20 +|Circuit breaker status |CBS|(% style="width:500px" %)status of protection disconnector;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
21 +|Close External 1 |CE1|(% style="width:500px" %)a request to close the External 1 discrete output (if assigned).|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
22 +|Close Main contactor |CMC|(% style="width:500px" %)a request to close the main contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
23 +|DCH contactor feedback |DCF|(% style="width:500px" %)a signal from discharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
24 +|Discharge request |DRE|(% style="width:500px" %)a request to close the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
25 +|Fuse 1|F1|(% style="width:500px" %)signal from fuse 1;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
26 +|Fuse 2|F2|(% style="width:500px" %)signal from fuse 2;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
27 +|Fuse 3 |F3|(% style="width:500px" %)signal from fuse 3;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
28 +|Inhibit charging |ICH|(% style="width:500px" %)a command to open the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
29 +|Inhibit discharging |IDC|(% style="width:500px" %)a command to open the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
30 +|Insulation status |INS|(% style="width:500px" %)a signal from an insulation monitoring device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
31 +|Interlock | |(% style="width:500px" %)a signal from interlock loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
32 +|Main contactor feedback |MCF|(% style="width:500px" %)a signal from main contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
33 +|PCH contactor feedback |PCF|(% style="width:500px" %)a signal from precharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
34 +|Power up/down request |PDN|(% style="width:500px" %)a request to power down the device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
35 +|Precharge request|PRE|(% style="width:500px" %)a request to close the precharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %) |(% style="width:137px" %) |(% style="width:137px" %)
35 35  
37 +(% class="wikigeneratedid" %)
38 +~* Contactor feedback signals in BMS Mini / BMS Mini S are connected to [[X1 header>>doc:Battery management systems.BMS Mini S.2\. Installation and connection.WebHome||anchor="HHeaders"]] and configured in "Signals → MOSFETs → Contactors feedback" section.
39 +
36 36  === List of internal states ===
37 37  
38 -Here is the list of available internal states of BMS Main 3.
42 +Here is the list of control internal states.
39 39  
40 40  (% style="width:1277px" %)
41 41  |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus**
42 42  |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3**
43 -|(% style="width:201px" %)Low SOC |(% style="width:55px" %)LOS|(% style="width:531px" %)a signal corresponding the low SOC of the battery;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
44 -|(% style="width:201px" %)High charging current |(% style="width:55px" %)HCC|(% style="width:531px" %)charging current is high;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
45 -|(% style="width:201px" %)Main contactor |(% style="width:55px" %)MCO|(% style="width:531px" %)state of the main contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
46 -|(% style="width:201px" %)Charging |(% style="width:55px" %)CH|(% style="width:531px" %)state of the charging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
47 -|(% style="width:201px" %)Allow charging |(% style="width:55px" %)ACH|(% style="width:531px" %)a signal for a charger to start charging;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
48 -|(% style="width:201px" %)Charging current present |(% style="width:55px" %)CCP|(% style="width:531px" %)the presence of the charging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
49 -|(% style="width:201px" %)Precharging |(% style="width:55px" %)PRE|(% style="width:531px" %)state of the precharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
50 -|(% style="width:201px" %)Discharging |(% style="width:55px" %)DCH|(% style="width:531px" %)state of the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
51 -|(% style="width:201px" %)Discharging current present |(% style="width:55px" %)DCP|(% style="width:531px" %)the presence of the discharging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
52 -|(% style="width:201px" %)Voltage too high for charging|(% style="width:55px" %)ENV|(% style="width:531px" %) |(% style="width:94px" %)Yes|(% style="width:75px" %) |(% style="width:84px" %) |(% style="width:140px" %) |(% style="width:142px" %)
53 -|(% style="width:201px" %)Discharging (AUX) |(% style="width:55px" %)AUX|(% style="width:531px" %)state of the auxiliary discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
54 -|(% style="width:201px" %)Power down ACK |(% style="width:55px" %)PDA|(% style="width:531px" %)an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
55 -|(% style="width:201px" %)Charging/discharging|(% style="width:55px" %)C/D|(% style="width:531px" %)state of the charging/discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
56 -|(% style="width:201px" %)Heater |(% style="width:55px" %)HEA|(% style="width:531px" %)a command to turn on a heater;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
57 -|(% style="width:201px" %)Cooler |(% style="width:55px" %)COO|(% style="width:531px" %)a command to turn on a cooler;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
58 -|(% style="width:201px" %)Shutdown request (HYG)|(% style="width:55px" %) |(% style="width:531px" %) |(% style="width:94px" %) |(% style="width:75px" %) |(% style="width:84px" %) |(% style="width:140px" %) |(% style="width:142px" %)
59 -|(% style="width:201px" %)Balancing 1 |(% style="width:55px" %)BA1|(% style="width:531px" %)balancing the first series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
60 -|(% style="width:201px" %)Balancing 2 |(% style="width:55px" %)BA2|(% style="width:531px" %)balancing the second series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
61 -|(% style="width:201px" %)Ready to charge |(% style="width:55px" %)RTC|(% style="width:531px" %)the battery is ready to be charged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
62 -|(% style="width:201px" %)Ready to discharge |(% style="width:55px" %)RTD|(% style="width:531px" %)the battery is ready to be discharged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
63 -|(% style="width:201px" %)Power up |(% style="width:55px" %)PUP|(% style="width:531px" %)an indication of BMS power status;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
64 -|(% style="width:201px" %)General error |(% style="width:55px" %) |(% style="width:531px" %)state of the configurable (general) error;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
65 -|(% style="width:201px" %)External 1 |(% style="width:55px" %)EX1|(% style="width:531px" %)a signal that activates by the remote request.|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
47 +|Allow charging |ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
48 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
49 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
50 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
51 +|Charging current present |CCP|the presence of the charging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
52 +|Charging |CH|state of the charging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
53 +|Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
54 +|Cooler |COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
55 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
56 +|Discharging (AUX) |AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
57 +|Discharging current present |DCP|the presence of the discharging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
58 +|Discharging |DCH|state of the discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
59 +|External 1 |EX1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
60 +|Heater |HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
61 +|Heater (AUX)|HA| | |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
62 +|High charging current |HCC|charging current is high;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
63 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
64 +|Low SOC |LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
65 +|Main contactor |MCO|state of the main contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
66 +|Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
67 +|Power up |PUP|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
68 +|Precharging |PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
69 +|Ready to charge |RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
70 +|Ready to discharge |RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
71 +|Crown EWS|EWS| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
72 +|Balancing 1 |BA1|balancing the first series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
73 +|Balancing 2 |BA2|balancing the second series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
74 +|Cell analysis|CEA| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
75 +|Shutdown request (Combilift)|CSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
76 +|Shutdown request (HYG/Spirit)|HSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
77 +|Voltage too high for charging|ENV| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
78 +|Init|INI| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
79 +|Service reset|SR| |Yes| |Yes|(% style="width:140px" %) |(% style="width:142px" %)
66 66  
67 -=== List of errors ===
81 +(% class="wikigeneratedid" %)
82 +Here is the list of internal states that are used just for information. They do not used to control or communicate with other devices and cannot be assigned to discrete output or relay.
68 68  
69 -Here is the list of error of BMS Main 3.
84 +(% style="width:1277px" %)
85 +|=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus**
86 +|=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3**
87 +|Crown EWS|EWS| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
88 +|Balancing 1 |BA1|balancing the first series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
89 +|Balancing 2 |BA2|balancing the second series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
90 +|Cell analysis|CEA| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
91 +|Shutdown request (Combilift)|CSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
92 +|Shutdown request (HYG/Spirit)|HSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
93 +|Voltage too high for charging|ENV| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
94 +|Init|INI| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
95 +|Service reset|SR| |Yes| |Yes|(% style="width:140px" %) |(% style="width:142px" %)
96 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
97 +| | | | | | |(% style="width:140px" %) |(% style="width:142px" %)
70 70  
99 +=== List of errors ===
100 +
71 71  (% style="width:1279px" %)
72 72  |(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:58px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="3" rowspan="1" style="width:248px" %)**Compability**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus**
73 73  |=(% style="width: 93px;" %)**Mini S / Mini**|=(% style="width: 76px;" %)**Main 2.1**|=(% style="width: 80px;" %)**Main 3**
74 -|(% style="width:196px" %)Overcurrent|(% style="width:58px" %)OC|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
75 -|(% style="width:196px" %)Undervoltage|(% style="width:58px" %)UV|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
76 -|(% style="width:196px" %)Overvoltage|(% style="width:58px" %)OV|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
77 -|(% style="width:196px" %)Low temperature (DCH) |(% style="width:58px" %)LDT|(% style="width:443px" %)temperature is too low for discharging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
78 -|(% style="width:196px" %)High temperature (DCH) |(% style="width:58px" %)HDT|(% style="width:443px" %)temperature is too high for discharging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
79 -|(% style="width:196px" %)Battery cover error |(% style="width:58px" %)BC|(% style="width:443px" %)battery cover is open;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
80 -|(% style="width:196px" %)High humidity |(% style="width:58px" %)HH|(% style="width:443px" %)humidity of the battery is increased;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
81 -|(% style="width:196px" %)Water |(% style="width:58px" %)WA|(% style="width:443px" %)there is water in the battery enclosure;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
82 -|(% style="width:196px" %)High Logic temperature |(% style="width:58px" %)LHT|(% style="width:443px" %)at least one of the Logic devices is overheated;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
83 -|(% style="width:196px" %)Logic offline |(% style="width:58px" %)LOF|(% style="width:443px" %)at least one of the Logic devices is offline;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
84 -|(% style="width:196px" %)Critical error|(% style="width:58px" %)CER|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
85 -|(% style="width:196px" %)Crown error |(% style="width:58px" %)CRO|(% style="width:443px" %)connection with a Crown forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
86 -|(% style="width:196px" %)Cell count error |(% style="width:58px" %)CEL|(% style="width:443px" %)number of cells does not match the specified value;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
87 -|(% style="width:196px" %)HYG offline |(% style="width:58px" %)HYG|(% style="width:443px" %)connection with a HYG forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
88 -|(% style="width:196px" %)Need acknowledge |(% style="width:58px" %)ACK|(% style="width:443px" %)there is an unacknowledged error in Error journal;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
89 -|(% style="width:196px" %)Combilift offline |(% style="width:58px" %)COM|(% style="width:443px" %)connection with a Combilift forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
90 -|(% style="width:196px" %)Short circuit|(% style="width:58px" %)SHC|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
91 -|(% style="width:196px" %)High contactor temperature|(% style="width:58px" %)CHT|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
92 -|(% style="width:196px" %)Logic count error|(% style="width:58px" %)LOG|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %)
93 -|(% style="width:196px" %)ADC error |(% style="width:58px" %)ADC|(% style="width:443px" %)current cannot be measured;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
94 -|(% style="width:196px" %)Current sensor error |(% style="width:58px" %)CSE|(% style="width:443px" %)error in the current sensor circuit;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
95 -|(% style="width:196px" %)CH contactor cycles error |(% style="width:58px" %)CCC|(% style="width:443px" %)switching frequency of the charging contactor is too high;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
96 -|(% style="width:196px" %)DCH contactor cycles error |(% style="width:58px" %)DCC|(% style="width:443px" %)switching frequency of the discharging contactor is too high;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
97 -|(% style="width:196px" %)Shunt offline |(% style="width:58px" %)SHO|(% style="width:443px" %)connection with the shunt current sensor is lost;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
98 -|(% style="width:196px" %)Shunt error |(% style="width:58px" %)SHE|(% style="width:443px" %)internal error of the shunt current sensor;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
99 -|(% style="width:196px" %)Settings error|(% style="width:58px" %)SET|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %)
100 -|(% style="width:196px" %)WDT reset |(% style="width:58px" %)WDT|(% style="width:443px" %)watchdog timer reset the device;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
101 -|(% style="width:196px" %)No temperature sensors |(% style="width:58px" %)NTS|(% style="width:443px" %)the device has no temperature sensors connected;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
102 -|(% style="width:196px" %)Temperature sensor is shorted |(% style="width:58px" %)TSS|(% style="width:443px" %)some temperature sensors are shorted;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
103 -|(% style="width:196px" %)Spirit offline |(% style="width:58px" %)SPI|(% style="width:443px" %)connection with a Spirit forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
104 -|(% style="width:196px" %)Mount error|(% style="width:58px" %)MNT|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
105 -|(% style="width:196px" %)FS error|(% style="width:58px" %)FSE|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
106 -|(% style="width:196px" %)Low temperature (CH) |(% style="width:58px" %)LCT|(% style="width:443px" %)temperature is too low for charging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
107 -|(% style="width:196px" %)High temperature (CH) |(% style="width:58px" %)HCT|(% style="width:443px" %)temperature is too high for charging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
108 -|(% style="width:196px" %)Unallowable charging |(% style="width:58px" %)UCH|(% style="width:443px" %)charging the battery through the discharging contactor;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
109 -|(% style="width:196px" %)Stuck contactor|(% style="width:58px" %)STC|(% style="width:443px" %) |(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
110 -|(% style="width:196px" %)CH contactor feedback error |(% style="width:58px" %)CCF|(% style="width:443px" %)the control signals for the charging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %)
111 -|(% style="width:196px" %)DCH contactor feedback error |(% style="width:58px" %)DCF|(% style="width:443px" %)the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %)
112 -|(% style="width:196px" %)Insulation fault;|(% style="width:58px" %)INF|(% style="width:443px" %) |(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
113 -|(% style="width:196px" %)PCH contactor feedback error |(% style="width:58px" %)PCF|(% style="width:443px" %)the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %)
114 -|(% style="width:196px" %)CH/DCH contactor feedback error |(% style="width:58px" %)CDF|(% style="width:443px" %)the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %)
115 -|(% style="width:196px" %)Main contactor feedback error |(% style="width:58px" %)MCF|(% style="width:443px" %)the control signals for the main contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %)
116 -|(% style="width:196px" %)Contactor feedback error|(% style="width:58px" %)CFE|(% style="width:443px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
117 -|(% style="width:196px" %)General error|(% style="width:58px" %)GE|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
118 -|(% style="width:196px" %)High voltage fault |(% style="width:58px" %)HVF|(% style="width:443px" %)failure of high voltage measuring circuits;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
119 -|(% style="width:196px" %)Power switch error |(% style="width:58px" %)PSE|(% style="width:443px" %)short circuit in contactor coil control circuit or power switch overheating;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
120 -|(% style="width:196px" %)HVIL error |(% style="width:58px" %)HE|(% style="width:443px" %)breakage of high-voltage interlock current loop;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
121 -|(% style="width:196px" %)Precharge error |(% style="width:58px" %)PE|(% style="width:443px" %)capacitive load pre-charge process did not end during the estimated time;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
122 -|(% style="width:196px" %)Power fault |(% style="width:58px" %)PF|(% style="width:443px" %)external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
123 -|(% style="width:196px" %)Current limit error |(% style="width:58px" %)CLE|(% style="width:443px" %)charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)
104 +|ADC error |ADC|current cannot be measured;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
105 +|Battery cover error |BC|battery cover is open;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
106 +|Cell count error |CEL|number of cells does not match the specified value;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
107 +|CH contactor cycles error |CCC|switching frequency of the charging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
108 +|CH contactor feedback error |CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %)
109 +|CH/DCH contactor feedback error |CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %)
110 +|Combilift offline |COM|connection with a Combilift forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
111 +|Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be | |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %)
112 +|Critical error|CER| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
113 +|Crown error |CRO|connection with a Crown forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
114 +|Current limit error |CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %)
115 +|Current sensor error |CSE|error in the current sensor circuit;||Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
116 +|DCH contactor cycles error |DCC|switching frequency of the discharging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
117 +|DCH contactor feedback error |DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %)
118 +|FS error|FSE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
119 +|General error|GE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
120 +|High contactor temperature|CHT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
121 +|High humidity |HH|humidity of the battery is increased;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
122 +|High Logic temperature |LHT|at least one of the Logic devices is overheated;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
123 +|High temperature (CH) |HCT|temperature is too high for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
124 +|High temperature (DCH) |HDT|temperature is too high for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
125 +|High voltage fault |HVF|failure of high voltage measuring circuits;|| | |Yes|(% style="width:142px" %) |(% style="width:134px" %)
126 +|HVIL error |HE|breakage of high-voltage interlock current loop;|| | |Yes|(% style="width:142px" %) |(% style="width:134px" %)
127 +|HYG offline |HYG|connection with a HYG forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
128 +|Insulation fault;|INF| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
129 +|Logic count error|LOG| | | | | |(% style="width:142px" %) |(% style="width:134px" %)
130 +|Logic offline |LOF|at least one of the Logic devices is offline;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
131 +|Low temperature (CH) |LCT|temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
132 +|Low temperature (DCH) |LDT|temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
133 +|Main contactor feedback error |MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %)
134 +|Mount error|MNT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
135 +|Need acknowledge |ACK|there is an unacknowledged error in Error journal;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
136 +|No temperature sensors |NTS|the device has no temperature sensors connected;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
137 +|Overcurrent|OC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
138 +|Overvoltage|OV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
139 +|PCH contactor feedback error |PCF|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %)
140 +|Power fault |PF|external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %)
141 +|Power switch error |PSE|short circuit in contactor coil control circuit or power switch overheating;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %)
142 +|Precharge error |PE|capacitive load pre-charge process did not end during the estimated time;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
143 +|Settings error|SET| | | | | |(% style="width:142px" %) |(% style="width:134px" %)
144 +|Short circuit|SHC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
145 +|Shunt error |SHE|internal error of the shunt current sensor;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
146 +|Shunt offline |SHO|connection with the shunt current sensor is lost;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
147 +|Spirit offline |SPI|connection with a Spirit forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
148 +|Stuck contactor|STC| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
149 +|Temperature sensor is shorted |TSS|some temperature sensors are shorted;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
150 +|Unallowable charging |UCH|charging the battery through the discharging contactor;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
151 +|Undervoltage|UV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
152 +|Water |WA|there is water in the battery enclosure;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
153 +|WDT reset |WDT|watchdog timer reset the device;||Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)
124 124  
125 125