Last modified by Admin on 2025/03/03 15:20

From version 9.18
edited by Admin
on 2025/01/30 14:36
Change comment: There is no comment for this version
To version 9.21
edited by Admin
on 2025/01/30 14:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -30,7 +30,11 @@
30 30  |Main contactor feedback |MCF|(% style="width:500px" %)a signal from main contactor feedback loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
31 31  |PCH contactor feedback |PCF|(% style="width:500px" %)a signal from precharging contactor feedback loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
32 32  |Power up/down request |PDN|(% style="width:500px" %)a request to power down the device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %)
33 +|Precharge request|PRE|(% style="width:500px" %)a request to close the precharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %) |(% style="width:137px" %) |(% style="width:137px" %)
33 33  
35 +(% class="wikigeneratedid" %)
36 +~* Contactor feedback signals in BMS Mini / BMS Mini S are connected to X1 header (Conta)
37 +
34 34  === List of internal states ===
35 35  
36 36  (% style="width:1277px" %)
... ... @@ -39,20 +39,20 @@
39 39  |Allow charging |ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
40 40  |Balancing 1 |BA1|balancing the first series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
41 41  |Balancing 2 |BA2|balancing the second series of cells;| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
42 -|Cell analysis|CEA| |Yes|Yes| |(% style="width:140px" %) |(% style="width:142px" %)
46 +|Cell analysis|CEA| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
43 43  |Charging current present |CCP|the presence of the charging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
44 44  |Charging |CH|state of the charging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
45 45  |Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
46 46  |Cooler |COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
47 -|Crown EWS|EWS| |Yes|Yes| |(% style="width:140px" %) |(% style="width:142px" %)
51 +|Crown EWS|EWS| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
48 48  |Discharging (AUX) |AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
49 49  |Discharging current present |DCP|the presence of the discharging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
50 50  |Discharging |DCH|state of the discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
51 51  |External 1 |EX1|a signal that activates by the remote request.| |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
52 52  |Heater |HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
53 -|Heater (AUX)|HA| | |Yes| |(% style="width:140px" %) |(% style="width:142px" %)
57 +|Heater (AUX)|HA| | |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
54 54  |High charging current |HCC|charging current is high;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
55 -|Init|INI| |Yes|Yes| |(% style="width:140px" %) |(% style="width:142px" %)
59 +|Init|INI| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
56 56  |Low SOC |LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
57 57  |Main contactor |MCO|state of the main contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
58 58  |Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
... ... @@ -60,10 +60,10 @@
60 60  |Precharging |PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
61 61  |Ready to charge |RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
62 62  |Ready to discharge |RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
63 -|Service reset|SR| |Yes| | |(% style="width:140px" %) |(% style="width:142px" %)
64 -|Shutdown request (Combilift)|CSH| |Yes|Yes| |(% style="width:140px" %) |(% style="width:142px" %)
65 -|Shutdown request (HYG/Spirit)|HSH| |Yes|Yes| |(% style="width:140px" %) |(% style="width:142px" %)
66 -|Voltage too high for charging|ENV| |Yes|Yes| |(% style="width:140px" %) |(% style="width:142px" %)
67 +|Service reset|SR| |Yes| |Yes|(% style="width:140px" %) |(% style="width:142px" %)
68 +|Shutdown request (Combilift)|CSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
69 +|Shutdown request (HYG/Spirit)|HSH| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
70 +|Voltage too high for charging|ENV| |Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %)
67 67  
68 68  === List of errors ===
69 69