Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,33 +6,37 @@ 6 6 7 7 === List of input signals === 8 8 9 -(% style="width:1278px" %) 10 -|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 60px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 500px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 243px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**Modbus** 11 -|=(% style="width: 92px;" %)**Mini S / Mini**|=(% style="width: 73px;" %)**Main 2.1**|=(% style="width: 78px;" %)**Main 3** 12 -|Balancing request |BR|(% style="width:500px" %)a request to balance the cells;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 13 -|Battery cover |CVR|(% style="width:500px" %)a signal from the battery cover;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 14 -|CH contactor feedback |CCF|(% style="width:500px" %)a signal from charging contactor feedback loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 15 -|CH/DCH contactor feedback |CDF|(% style="width:500px" %)a signal from charging/discharging contactor feedback loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 16 -|Charge request |CRE|(% style="width:500px" %)a request to close the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 17 -|Charger connected |CON|(% style="width:500px" %)a signal indicating that charger is connected;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 18 -|Circuit breaker status |CBS|(% style="width:500px" %)status of protection disconnector;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 19 -|Close External 1 |CE1|(% style="width:500px" %)a request to close the External 1 discrete output (if assigned).|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 20 -|Close Main contactor |CMC|(% style="width:500px" %)a request to close the main contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 21 -|DCH contactor feedback |DCF|(% style="width:500px" %)a signal from discharging contactor feedback loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 22 -|Discharge request |DRE|(% style="width:500px" %)a request to close the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 23 -|Fuse 1|F1|(% style="width:500px" %)signal from fuse 1;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 24 -|Fuse 2|F2|(% style="width:500px" %)signal from fuse 2;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 25 -|Fuse 3 |F3|(% style="width:500px" %)signal from fuse 3;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 26 -|Inhibit charging |ICH|(% style="width:500px" %)a command to open the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 27 -|Inhibit discharging |IDC|(% style="width:500px" %)a command to open the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 28 -|Insulation status |INS|(% style="width:500px" %)a signal from an insulation monitoring device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 29 -|Interlock | |(% style="width:500px" %)a signal from interlock loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 30 -|Main contactor feedback |MCF|(% style="width:500px" %)a signal from main contactor feedback loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 31 -|PCH contactor feedback |PCF|(% style="width:500px" %)a signal from precharging contactor feedback loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 32 -|Power up/down request |PDN|(% style="width:500px" %)a request to power down the device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 9 +Here is the list of available input signals of BMS Main 3. 33 33 11 +(% style="width:1274px" %) 12 +|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 60px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 483px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 248px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 143px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**Modbus** 13 +|=(% style="width: 98px;" %)**Mini S / Mini**|=(% style="width: 77px;" %)**Main 2.1**|=(% style="width: 81px;" %)**Main 3** 14 +|Balancing request |BR|a request to balance the cells;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 15 +|Battery cover |CVR|a signal from the battery cover;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 16 +|CH contactor feedback |CCF|a signal from charging contactor feedback loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 17 +|CH/DCH contactor feedback |CDF|a signal from charging/discharging contactor feedback loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 18 +|Charge request |CRE|a request to close the charging contactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 19 +|Charger connected |CON|a signal indicating that charger is connected;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 20 +|Circuit breaker status |CBS|status of protection disconnector;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 21 +|Close External 1 |CE1|a request to close the External 1 discrete output (if assigned).|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 22 +|Close Main contactor |CMC|a request to close the main contactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 23 +|DCH contactor feedback |DCF|a signal from discharging contactor feedback loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 24 +|Discharge request |DRE|a request to close the discharging contactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 25 +|Fuse 1|F1|signal from fuse 1;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 26 +|Fuse 2|F2|signal from fuse 2;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 27 +|Fuse 3 |F3|signal from fuse 3;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 28 +|Inhibit charging |ICH|a command to open the charging contactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 29 +|Inhibit discharging |IDC|a command to open the discharging contactor;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 30 +|Insulation status |INS|a signal from an insulation monitoring device;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 31 +|Interlock | |a signal from interlock loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 32 +|Main contactor feedback |MCF|a signal from main contactor feedback loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 33 +|PCH contactor feedback |PCF|a signal from precharging contactor feedback loop;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 34 +|Power up/down request |PDN|a request to power down the device;|Yes|Yes|Yes|(% style="width:143px" %) |(% style="width:140px" %) 35 + 34 34 === List of internal states === 35 35 38 +Here is the list of available internal states of BMS Main 3. 39 + 36 36 (% style="width:1277px" %) 37 37 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 38 38 |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** ... ... @@ -39,12 +39,12 @@ 39 39 |Allow charging |ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 40 40 |Balancing 1 |BA1|balancing the first series of cells;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 41 41 |Balancing 2 |BA2|balancing the second series of cells;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 42 -|Cell analysis|CEA| |Yes| Yes| |(% style="width:140px" %) |(% style="width:142px" %)46 +|Cell analysis|CEA| |Yes| | |(% style="width:140px" %) |(% style="width:142px" %) 43 43 |Charging current present |CCP|the presence of the charging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 44 44 |Charging |CH|state of the charging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 45 45 |Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 46 46 |Cooler |COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 47 -|Crown EWS|EWS| |Yes| Yes| |(% style="width:140px" %) |(% style="width:142px" %)51 +|Crown EWS|EWS| |Yes| | |(% style="width:140px" %) |(% style="width:142px" %) 48 48 |Discharging (AUX) |AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 49 49 |Discharging current present |DCP|the presence of the discharging current;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 50 50 |Discharging |DCH|state of the discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) ... ... @@ -66,58 +66,60 @@ 66 66 67 67 === List of errors === 68 68 73 +Here is the list of error of BMS Main 3. 74 + 69 69 (% style="width:1279px" %) 70 70 |(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:58px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="3" rowspan="1" style="width:248px" %)**Compability**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus** 71 71 |=(% style="width: 93px;" %)**Mini S / Mini**|=(% style="width: 76px;" %)**Main 2.1**|=(% style="width: 80px;" %)**Main 3** 72 -| ADCerror|ADC|currentcannotbemeasured;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)73 -| Battery covererror|BC|batterycoveris open;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)74 -| Cellcountrror|CEL|numberf cells doesnotmatch the specifiedvalue;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)75 -| CHcontactor cycleserror|CCC|switchingfrequencyofthechargingcontactoristoohigh;||Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)76 -| CHcontactorfeedback error|CCF|thecontrolsignalsforthechargingcontactorandthecontactor feedbackdiffer;|•||Yes||(% style="width:142px" %) |(% style="width:134px" %)77 -| CH/DCHcontactorfeedbackerror |CDF|the controlsignalsforthecharging/dischargingcontactorandcontactor feedbackdiffer;|•||Yes||(% style="width:142px" %) |(% style="width:134px" %)78 -| Combiliftoffline|COM|connectionwitha Combiliftforklift islost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)79 -| Contactorfeedbackerror|CFE|Failureofoneofthecontactorsfeedbacksignal. Whichcontactorisfailedcan be|Yes||Yes|(% style="width:142px" %) |(% style="width:134px" %)80 -| Criticalerror|CER| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)81 -| Crownerror|CRO|connectionwith aCrownforklift islost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)82 -| Currentlimit errorLE|chargingor discharging currentismorethanlimitcalculatedby Charge maporDischargemap.||Yes||Yes|(% style="width:142px" %) |(% style="width:134px" %)83 -| Currentsensor error |CSE|errorinthecurrentsensorcircuit;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)84 -| DCHcontactorcycles error |DCC|switchingfrequencyofthe dischargingcontactoristoohigh;||Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)85 -| DCHcontactorfeedbackerror|DCF|the controlsignalsforhedischargingcontactorandecontactorfeedbackdiffer;|•||Yes||(% style="width:142px" %) |(% style="width:134px" %)86 -| FSerror|FSE|| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)87 -| General error|GE|| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)88 -| Highcontactor temperature|CHT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)89 -|High humidity|HH|humidityofthebatterysincreased;||Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)90 -| High Logic temperature|LHT|atleastoneoftheLogicdevicesisoverheated;||Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)91 -| Hightemperature(CH)|HCT|temperatureisoo highforcharging;||Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)92 -| Hightemperature (DCH)|HDT|temperatureistoohighfordischarging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)93 -| Highvoltagefault |HVF|failureofhighvoltagemeasuring circuits;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %)94 -|H VILerror |HE|breakage of high-voltageinterlockcurrentloop;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %)95 -| HYGoffline |HYG|connection withaHYGforklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)96 -| Insulation fault;|INF||•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)97 -| Logiccount error|LOG| | | | | |(% style="width:142px" %) |(% style="width:134px" %)98 -| Logicoffline |LOF|atleast oneoftheLogicdevicesisoffline;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)99 -| Low temperature(CH)|LCT|temperatureistoo low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)100 -| Lowtemperature(DCH)|LDT|temperatureistoolow fordischarging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)101 -| Maincontactor feedbackerror|MCF|the controlsignalsforhemaincontactorandecontactorfeedbackdiffer;|•||Yes||(% style="width:142px" %) |(% style="width:134px" %)102 -|Mount error|MNT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 103 -| Needacknowledge |ACK|thereisan unacknowledged error inErrorjournal;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)104 -| No temperature sensors|NTS|thedevicehasnotemperature sensorsconnected;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)105 -| Overcurrent|OC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)106 -| Overvoltage|OV|| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)107 -| PCHcontactorfeedbackerror |PCF|thecontrolsignalsfortheprecharging contactorandthecontactor feedbackdiffer;|•||Yes||(% style="width:142px" %) |(% style="width:134px" %)108 -| Powerfault|PF|externaldevicespower supply error:current sensors,HVIL,BMS LogicorCAN2 (int)bus powered devices;|•|||Yes|(% style="width:142px" %) |(% style="width:134px" %)109 -| Powerswitch error |PSE|short circuit in contactorcoilcontrolcircuitpower switchoverheating;|•|||Yes|(% style="width:142px" %) |(% style="width:134px" %)110 -| Prechargeerror |PE|capacitiveloadpre-chargeprocess didnotendduringtheestimated time;||Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)111 -| Settings error|SET|| | | | |(% style="width:142px" %) |(% style="width:134px" %)112 -| Short circuit|SHC|||Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)113 -| Shunt error |SHE|internalerroroftheshuntcurrentsensor;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)114 -| Shuntoffline|SHO|connectionwiththeshuntcurrent sensor is lost;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)115 -| Spiritoffline|SPI|connectionwithaSpiritforkliftislost;||Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)116 -| Stuckcontactor|STC| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)117 -| Temperaturesensorisshorted|TSS|sometemperaturesensorsare shorted;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)118 -| Unallowablecharging|UCH|chargingthe batterythroughthe dischargingcontactor;||Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)119 -| Undervoltage|UV|| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)120 -| Water |WA|there is waterinthebatteryenclosure;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)121 -| WDTreset |WDT|watchdogtimer resetthedevice;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %)78 +|(% style="width:196px" %)Overcurrent|(% style="width:58px" %)OC|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 79 +|(% style="width:196px" %)Undervoltage|(% style="width:58px" %)UV|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 80 +|(% style="width:196px" %)Overvoltage|(% style="width:58px" %)OV|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 81 +|(% style="width:196px" %)Low temperature (DCH) |(% style="width:58px" %)LDT|(% style="width:443px" %)temperature is too low for discharging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 82 +|(% style="width:196px" %)High temperature (DCH) |(% style="width:58px" %)HDT|(% style="width:443px" %)temperature is too high for discharging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 83 +|(% style="width:196px" %)Battery cover error |(% style="width:58px" %)BC|(% style="width:443px" %)battery cover is open;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 84 +|(% style="width:196px" %)High humidity |(% style="width:58px" %)HH|(% style="width:443px" %)humidity of the battery is increased;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 85 +|(% style="width:196px" %)Water |(% style="width:58px" %)WA|(% style="width:443px" %)there is water in the battery enclosure;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 86 +|(% style="width:196px" %)High Logic temperature |(% style="width:58px" %)LHT|(% style="width:443px" %)at least one of the Logic devices is overheated;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 87 +|(% style="width:196px" %)Logic offline |(% style="width:58px" %)LOF|(% style="width:443px" %)at least one of the Logic devices is offline;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 88 +|(% style="width:196px" %)Critical error|(% style="width:58px" %)CER|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 89 +|(% style="width:196px" %)Crown error |(% style="width:58px" %)CRO|(% style="width:443px" %)connection with a Crown forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 90 +|(% style="width:196px" %)Cell count error |(% style="width:58px" %)CEL|(% style="width:443px" %)number of cells does not match the specified value;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 91 +|(% style="width:196px" %)HYG offline |(% style="width:58px" %)HYG|(% style="width:443px" %)connection with a HYG forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 92 +|(% style="width:196px" %)Need acknowledge |(% style="width:58px" %)ACK|(% style="width:443px" %)there is an unacknowledged error in Error journal;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 93 +|(% style="width:196px" %)Combilift offline |(% style="width:58px" %)COM|(% style="width:443px" %)connection with a Combilift forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 94 +|(% style="width:196px" %)Short circuit|(% style="width:58px" %)SHC|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 95 +|(% style="width:196px" %)High contactor temperature|(% style="width:58px" %)CHT|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 96 +|(% style="width:196px" %)Logic count error|(% style="width:58px" %)LOG|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 97 +|(% style="width:196px" %)ADC error |(% style="width:58px" %)ADC|(% style="width:443px" %)current cannot be measured;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 98 +|(% style="width:196px" %)Current sensor error |(% style="width:58px" %)CSE|(% style="width:443px" %)error in the current sensor circuit;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 99 +|(% style="width:196px" %)CH contactor cycles error |(% style="width:58px" %)CCC|(% style="width:443px" %)switching frequency of the charging contactor is too high;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 100 +|(% style="width:196px" %)DCH contactor cycles error |(% style="width:58px" %)DCC|(% style="width:443px" %)switching frequency of the discharging contactor is too high;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 101 +|(% style="width:196px" %)Shunt offline |(% style="width:58px" %)SHO|(% style="width:443px" %)connection with the shunt current sensor is lost;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 102 +|(% style="width:196px" %)Shunt error |(% style="width:58px" %)SHE|(% style="width:443px" %)internal error of the shunt current sensor;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 103 +|(% style="width:196px" %)Settings error|(% style="width:58px" %)SET|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 104 +|(% style="width:196px" %)WDT reset |(% style="width:58px" %)WDT|(% style="width:443px" %)watchdog timer reset the device;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 105 +|(% style="width:196px" %)No temperature sensors |(% style="width:58px" %)NTS|(% style="width:443px" %)the device has no temperature sensors connected;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 106 +|(% style="width:196px" %)Temperature sensor is shorted |(% style="width:58px" %)TSS|(% style="width:443px" %)some temperature sensors are shorted;|(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 107 +|(% style="width:196px" %)Spirit offline |(% style="width:58px" %)SPI|(% style="width:443px" %)connection with a Spirit forklift is lost;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 108 +|(% style="width:196px" %)Mount error|(% style="width:58px" %)MNT|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 +|(% style="width:196px" %)FS error|(% style="width:58px" %)FSE|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 110 +|(% style="width:196px" %)Low temperature (CH) |(% style="width:58px" %)LCT|(% style="width:443px" %)temperature is too low for charging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 111 +|(% style="width:196px" %)High temperature (CH) |(% style="width:58px" %)HCT|(% style="width:443px" %)temperature is too high for charging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 112 +|(% style="width:196px" %)Unallowable charging |(% style="width:58px" %)UCH|(% style="width:443px" %)charging the battery through the discharging contactor;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 113 +|(% style="width:196px" %)Stuck contactor|(% style="width:58px" %)STC|(% style="width:443px" %) |(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 114 +|(% style="width:196px" %)CH contactor feedback error |(% style="width:58px" %)CCF|(% style="width:443px" %)the control signals for the charging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 115 +|(% style="width:196px" %)DCH contactor feedback error |(% style="width:58px" %)DCF|(% style="width:443px" %)the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 116 +|(% style="width:196px" %)Insulation fault;|(% style="width:58px" %)INF|(% style="width:443px" %) |(% style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 117 +|(% style="width:196px" %)PCH contactor feedback error |(% style="width:58px" %)PCF|(% style="width:443px" %)the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 118 +|(% style="width:196px" %)CH/DCH contactor feedback error |(% style="width:58px" %)CDF|(% style="width:443px" %)the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 119 +|(% style="width:196px" %)Main contactor feedback error |(% style="width:58px" %)MCF|(% style="width:443px" %)the control signals for the main contactor and the contactor feedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %) 120 +|(% style="width:196px" %)Contactor feedback error|(% style="width:58px" %)CFE|(% style="width:443px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 121 +|(% style="width:196px" %)General error|(% style="width:58px" %)GE|(% style="width:443px" %) |(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 122 +|(% style="width:196px" %)High voltage fault |(% style="width:58px" %)HVF|(% style="width:443px" %)failure of high voltage measuring circuits;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 123 +|(% style="width:196px" %)Power switch error |(% style="width:58px" %)PSE|(% style="width:443px" %)short circuit in contactor coil control circuit or power switch overheating;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 124 +|(% style="width:196px" %)HVIL error |(% style="width:58px" %)HE|(% style="width:443px" %)breakage of high-voltage interlock current loop;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 125 +|(% style="width:196px" %)Precharge error |(% style="width:58px" %)PE|(% style="width:443px" %)capacitive load pre-charge process did not end during the estimated time;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 126 +|(% style="width:196px" %)Power fault |(% style="width:58px" %)PF|(% style="width:443px" %)external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:67px" %)•|(% style="width:93px" %) |(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 127 +|(% style="width:196px" %)Current limit error |(% style="width:58px" %)CLE|(% style="width:443px" %)charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %) |(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %) 122 122 123 123