Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,118 +6,136 @@ 6 6 7 7 === List of input signals === 8 8 9 -Here is the list of available input signals of BMSMain3.9 +Here is the list of input signals that can be assigned to discrete inputs of BMS controller. 10 10 11 -(% style="width:1274px" %) 12 -|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 60px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 483px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 248px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 143px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**Modbus** 13 -|=(% style="width: 98px;" %)**Mini S / Mini**|=(% style="width: 77px;" %)**Main 2.1**|=(% style="width: 81px;" %)**Main 3** 14 -|(% style="width:198px" %)Battery cover |(% style="width:60px" %)CVR|(% style="width:483px" %)a signal from the battery cover;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 15 -|(% style="width:198px" %)Charger connected |(% style="width:60px" %)CON|(% style="width:483px" %)a signal indicating that charger is connected;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 16 -|(% style="width:198px" %)Power up/down request |(% style="width:60px" %)PDN|(% style="width:483px" %)a request to power down the device;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 17 -|(% style="width:198px" %)Inhibit charging |(% style="width:60px" %)ICH|(% style="width:483px" %)a command to open the charging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 18 -|(% style="width:198px" %)Inhibit discharging |(% style="width:60px" %)IDC|(% style="width:483px" %)a command to open the discharging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 19 -|(% style="width:198px" %)CH contactor feedback |(% style="width:60px" %)CCF|(% style="width:483px" %)a signal from charging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 20 -|(% style="width:198px" %)DCH contactor feedback |(% style="width:60px" %)DCF|(% style="width:483px" %)a signal from discharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 21 -|(% style="width:198px" %)Insulation status |(% style="width:60px" %)INS|(% style="width:483px" %)a signal from an insulation monitoring device;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 22 -|(% style="width:198px" %)Charge request |(% style="width:60px" %)CRE|(% style="width:483px" %)a request to close the charging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 23 -|(% style="width:198px" %)Discharge request |(% style="width:60px" %)DRE|(% style="width:483px" %)a request to close the discharging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 24 -|(% style="width:198px" %)PCH contactor feedback |(% style="width:60px" %)PCF|(% style="width:483px" %)a signal from precharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 25 -|(% style="width:198px" %)CH/DCH contactor feedback |(% style="width:60px" %)CDF|(% style="width:483px" %)a signal from charging/discharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 26 -|(% style="width:198px" %)Main contactor feedback |(% style="width:60px" %)MCF|(% style="width:483px" %)a signal from main contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 27 -|(% style="width:198px" %)Interlock |(% style="width:60px" %) |(% style="width:483px" %)a signal from interlock loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 28 -|(% style="width:198px" %)Fuse 1|(% style="width:60px" %)F1|(% style="width:483px" %)signal from fuse 1;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 29 -|(% style="width:198px" %)Fuse 2|(% style="width:60px" %)F2|(% style="width:483px" %)signal from fuse 2;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 30 -|(% style="width:198px" %)Fuse 3 |(% style="width:60px" %)F3|(% style="width:483px" %)signal from fuse 3;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 31 -|(% style="width:198px" %)Circuit breaker status |(% style="width:60px" %)CBS|(% style="width:483px" %)status of protection disconnector;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 32 -|(% style="width:198px" %)Balancing request |(% style="width:60px" %)BR|(% style="width:483px" %)a request to balance the cells;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 33 -|(% style="width:198px" %)Close Main contactor |(% style="width:60px" %)CMC|(% style="width:483px" %)a request to close the main contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 34 -|(% style="width:198px" %)Close External 1 |(% style="width:60px" %)CE1|(% style="width:483px" %)a request to close the External 1 discrete output (if assigned).|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 11 +(% style="width:1278px" %) 12 +|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 60px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 500px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 243px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 137px;" %)**Modbus** 13 +|=(% style="width: 92px;" %)**Mini S / Mini**|=(% style="width: 73px;" %)**Main 2.1**|=(% style="width: 78px;" %)**Main 3** 14 +|Balancing request |BR|(% style="width:500px" %)a request to balance the cells;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 15 +|Battery cover |CVR|(% style="width:500px" %)a signal from the battery cover;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 16 +|CH contactor feedback |CCF|(% style="width:500px" %)a signal from charging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 17 +|CH/DCH contactor feedback |CDF|(% style="width:500px" %)a signal from charging/discharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 18 +|Charge request |CRE|(% style="width:500px" %)a request to close the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 19 +|Charger connected |CON|(% style="width:500px" %)a signal indicating that charger is connected;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 20 +|Circuit breaker status |CBS|(% style="width:500px" %)status of protection disconnector;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 21 +|Close External 1 |CE1|(% style="width:500px" %)a request to close the External 1 discrete output (if assigned).|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 22 +|Close Main contactor |CMC|(% style="width:500px" %)a request to close the main contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 23 +|DCH contactor feedback |DCF|(% style="width:500px" %)a signal from discharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 24 +|Discharge request |DRE|(% style="width:500px" %)a request to close the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 25 +|Fuse 1|F1|(% style="width:500px" %)signal from fuse 1;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 26 +|Fuse 2|F2|(% style="width:500px" %)signal from fuse 2;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 27 +|Fuse 3 |F3|(% style="width:500px" %)signal from fuse 3;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 28 +|Inhibit charging |ICH|(% style="width:500px" %)a command to open the charging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 29 +|Inhibit discharging |IDC|(% style="width:500px" %)a command to open the discharging contactor;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 30 +|Insulation status |INS|(% style="width:500px" %)a signal from an insulation monitoring device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 31 +|Interlock | |(% style="width:500px" %)a signal from interlock loop;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 32 +|Main contactor feedback |MCF|(% style="width:500px" %)a signal from main contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 33 +|PCH contactor feedback |PCF|(% style="width:500px" %)a signal from precharging contactor feedback loop;|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 34 +|Power up/down request |PDN|(% style="width:500px" %)a request to power down the device;|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) |(% style="width:137px" %) 35 +|Precharge request|PRE|(% style="width:500px" %)a request to close the precharging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %) |(% style="width:137px" %) |(% style="width:137px" %) 35 35 37 +(% class="wikigeneratedid" %) 38 +~* Contactor feedback signals in BMS Mini / BMS Mini S are connected to [[X1 header>>doc:Battery management systems.BMS Mini S.2\. Installation and connection.WebHome||anchor="HHeaders"]] and configured in "Signals → MOSFETs → Contactors feedback" section. 39 + 36 36 === List of internal states === 37 37 38 -Here is the list of availableinternal states ofBMSMain3.42 +Here is the list of control internal states. Signals marked with bold text can be assigned to discrete output or relay. 39 39 40 40 (% style="width:1277px" %) 41 41 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 42 42 |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** 43 -|(% style="width:201px" %)Low SOC |(% style="width:55px" %)LOS|(% style="width:531px" %)a signal corresponding the low SOC of the battery;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 44 -|(% style="width:201px" %)High charging current |(% style="width:55px" %)HCC|(% style="width:531px" %)charging current is high;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 45 -|(% style="width:201px" %)Main contactor |(% style="width:55px" %)MCO|(% style="width:531px" %)state of the main contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 46 -|(% style="width:201px" %)Charging |(% style="width:55px" %)CH|(% style="width:531px" %)state of the charging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 47 -|(% style="width:201px" %)Allow charging |(% style="width:55px" %)ACH|(% style="width:531px" %)a signal for a charger to start charging;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 48 -|(% style="width:201px" %)Charging current present |(% style="width:55px" %)CCP|(% style="width:531px" %)the presence of the charging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 49 -|(% style="width:201px" %)Precharging |(% style="width:55px" %)PRE|(% style="width:531px" %)state of the precharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 50 -|(% style="width:201px" %)Discharging |(% style="width:55px" %)DCH|(% style="width:531px" %)state of the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 51 -|(% style="width:201px" %)Discharging current present |(% style="width:55px" %)DCP|(% style="width:531px" %)the presence of the discharging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 52 -|(% style="width:201px" %)Discharging (AUX) |(% style="width:55px" %)AUX|(% style="width:531px" %)state of the auxiliary discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 53 -|(% style="width:201px" %)Power down ACK |(% style="width:55px" %)PDA|(% style="width:531px" %)an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 54 -|(% style="width:201px" %)Charging/discharging|(% style="width:55px" %)C/D|(% style="width:531px" %)state of the charging/discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 55 -|(% style="width:201px" %)Heater |(% style="width:55px" %)HEA|(% style="width:531px" %)a command to turn on a heater;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 56 -|(% style="width:201px" %)Cooler |(% style="width:55px" %)COO|(% style="width:531px" %)a command to turn on a cooler;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 57 -|(% style="width:201px" %)Balancing 1 |(% style="width:55px" %)BA1|(% style="width:531px" %)balancing the first series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 58 -|(% style="width:201px" %)Balancing 2 |(% style="width:55px" %)BA2|(% style="width:531px" %)balancing the second series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 59 -|(% style="width:201px" %)Ready to charge |(% style="width:55px" %)RTC|(% style="width:531px" %)the battery is ready to be charged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 60 -|(% style="width:201px" %)Ready to discharge |(% style="width:55px" %)RTD|(% style="width:531px" %)the battery is ready to be discharged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 61 -|(% style="width:201px" %)Power up |(% style="width:55px" %)PUP|(% style="width:531px" %)an indication of BMS power status;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 62 -|(% style="width:201px" %)General error |(% style="width:55px" %) |(% style="width:531px" %)state of the configurable (general) error;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 63 -|(% style="width:201px" %)External 1 |(% style="width:55px" %)EX1|(% style="width:531px" %)a signal that activates by the remote request.|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 47 +|Allow charging |ACH|a signal for a charger to start charging;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 48 +|Balancing 1 |BA1|balancing the first series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 49 +|Balancing 2 |BA2|balancing the second series of cells;| |Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 50 +|Cell analysis|CEA| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 51 +|Charging current present |CCP|the presence of the charging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 52 +|Charging |CH|state of the charging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 53 +|Charging/discharging|C/D|state of the charging/discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 54 +|Cooler |COO|a command to turn on a cooler;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 55 +|Crown EWS|EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 56 +|Discharging (AUX) |AUX|state of the auxiliary discharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 57 +|Discharging current present |DCP|the presence of the discharging current;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 58 +|Discharging |DCH|state of the discharging contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 59 +|External 1 |EX1|a signal that activates by the remote request.|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 60 +|Heater (AUX)|HA| | |Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 61 +|Heater |HEA|a command to turn on a heater;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 62 +|High charging current |HCC|charging current is high;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 63 +|Init|INI| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 64 +|Low SOC |LOS|a signal corresponding the low SOC of the battery;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 65 +|Main contactor |MCO|state of the main contactor;|Yes|Yes*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 66 +|Power down ACK |PDA|an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|Yes|Yes~*~*|Yes|(% style="width:140px" %) |(% style="width:142px" %) 67 +|Power up |PUP|an indication of BMS power status;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 68 +|Precharging |PRE|state of the precharging contactor;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 69 +|Ready to charge |RTC|the battery is ready to be charged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 70 +|Ready to discharge |RTD|the battery is ready to be discharged;|Yes|Yes|Yes|(% style="width:140px" %) |(% style="width:142px" %) 71 +|Service reset|SR| |Yes~*~**| |Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 72 +|Shutdown request (Combilift)|CSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 73 +|Shutdown request (HYG/Spirit)|HSH| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 74 +|Voltage too high for charging|ENV| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %) |(% style="width:142px" %) 64 64 65 -=== List of errors === 76 +(% class="wikigeneratedid" %) 77 +~* assignable to relay only 66 66 67 -Here is the list of error of BMS Main 3. 79 +(% class="wikigeneratedid" %) 80 +~** assignable to discrete input only 68 68 82 +(% class="wikigeneratedid" %) 83 +~*~*~* state is indicative only and cannot be assigned to discrete output or relay. 84 + 85 +=== List of errors === 86 + 69 69 (% style="width:1279px" %) 70 70 |(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:58px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="3" rowspan="1" style="width:248px" %)**Compability**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus** 71 71 |=(% style="width: 93px;" %)**Mini S / Mini**|=(% style="width: 76px;" %)**Main 2.1**|=(% style="width: 80px;" %)**Main 3** 72 -| (%style="width:196px" %)Overcurrent|(%style="width:58px"%)OC|(% style="width:443px"%) |(% style="width:67px" %) |(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)73 -| (% style="width:196px" %)Undervoltage|(%style="width:58px"%)UV|(% style="width:443px" %)|(% style="width:67px" %) |(% style="width:93px"%)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)74 -| (%style="width:196px"%)Overvoltage|(%style="width:58px"%)OV|(% style="width:443px"%) |(%style="width:67px"%) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)75 -| (%style="width:196px"%)Low temperature(DCH)|(%style="width:58px" %)LDT|(% style="width:443px"%)temperatureis too lowfordischarging;|(%style="width:67px"%) |(%style="width:93px"%)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)76 -| (% style="width:196px" %)Hightemperature(DCH) |(% style="width:58px" %)HDT|(% style="width:443px"%)temperatureistoohighfordischarging;|(%style="width:67px"%)|(% style="width:93px" %)Yes|(%style="width:76px"%)Yes|(% style="width:80px"%)Yes|(% style="width:142px" %) |(% style="width:134px" %)77 -| (%style="width:196px" %)Batterycovererror |(% style="width:58px" %)BC|(% style="width:443px" %)batterycover is open;|(%style="width:67px"%)•|(% style="width:93px" %)Yes|(%style="width:76px"%)Yes|(% style="width:80px"%)Yes|(% style="width:142px" %) |(% style="width:134px" %)78 -| (% style="width:196px" %)High humidity|(% style="width:58px"%)HH|(% style="width:443px"%)humidityofhebatteryisincreased;|(%style="width:67px" %)|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)79 -| (% style="width:196px" %)Water|(% style="width:58px" %)WA|(% style="width:443px"%)thereiswaterinthebatteryenclosure;|(%style="width:67px"%)•|(% style="width:93px"%)Yes|(%style="width:76px"%)Yes|(%style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)80 -| (% style="width:196px" %)High Logictemperature |(% style="width:58px"%)LHT|(% style="width:443px" %)at leastone of the Logic devices is overheated;|(%style="width:67px" %)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)81 -| (% style="width:196px"%)Logicoffline|(% style="width:58px"%)LOF|(% style="width:443px"%)atleastoneofheLogic devicesis offline;|(%style="width:67px" %)•|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)82 -| (% style="width:196px"%)Criticalerror|(%style="width:58px" %)CER|(%style="width:443px"%)|(%style="width:67px"%) |(% style="width:93px"%)Yes|(%style="width:76px"%)Yes|(%style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)83 -| (% style="width:196px"%)Crown error |(% style="width:58px" %)CRO|(% style="width:443px" %)connectionwitha Crownforkliftis lost;|(% style="width:67px" %)|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)84 -| (% style="width:196px" %)Cellcount error |(% style="width:58px" %)CEL|(%style="width:443px" %)numberofcellsdoesmatchthespecified value;|(%style="width:67px" %)•|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)85 -| (%style="width:196px" %)HYGoffline|(% style="width:58px"%)HYG|(%style="width:443px"%)connectionwithaHYGforklift islost;|(% style="width:67px"%) |(% style="width:93px"%)Yes|(% style="width:76px"%)Yes|(%style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)86 -| (%style="width:196px" %)Need acknowledge |(% style="width:58px" %)ACK|(% style="width:443px" %)there is an unacknowledged errorinError journal;|(%style="width:67px" %)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)87 -| (% style="width:196px" %)Combilift offline|(% style="width:58px" %)COM|(% style="width:443px" %)connection withaCombiliftforklift is lost;|(%style="width:67px" %)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)88 -| (% style="width:196px"%)Shortircuit|(%style="width:58px" %)SHC|(% style="width:443px" %)|(%style="width:67px" %)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)89 -| (% style="width:196px" %)Highcontactor temperature|(% style="width:58px"%)CHT|(% style="width:443px"%)|(% style="width:67px"%) |(% style="width:93px"%)Yes|(% style="width:76px"%)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)90 -| (% style="width:196px"%)Logiccountror|(% style="width:58px"%)LOG|(% style="width:443px"%)|(%style="width:67px"%) |(% style="width:93px"%) |(%style="width:76px" %)|(%style="width:80px" %)|(% style="width:142px" %) |(% style="width:134px" %)91 -| (%style="width:196px" %)ADCerror |(% style="width:58px"%)ADC|(% style="width:443px" %)current cannotbe measured;|(%style="width:67px"%)•|(%style="width:93px"%)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)92 -| (% style="width:196px"%)Currentsensorerror |(% style="width:58px"%)CSE|(%style="width:443px" %)errorinthecurrent sensorcircuit;|(%style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)93 -| (% style="width:196px"%)CH contactor cycleserror |(% style="width:58px"%)CCC|(% style="width:443px"%)switchingfrequencyofthecharging contactorstoo high;|(% style="width:67px" %)|(%style="width:93px" %)Yes|(%style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)94 -| (% style="width:196px" %)DCHcontactor cycles error |(% style="width:58px" %)DCC|(% style="width:443px" %)switchingfrequencyofthe dischargingcontactoris toohigh;|(% style="width:67px" %)|(%style="width:93px" %)Yes|(%style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)95 -| (%style="width:196px" %)Shuntoffline |(% style="width:58px" %)SHO|(% style="width:443px" %)connection withtheshuntcurrentsensoris lost;|(%style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)96 -| (% style="width:196px" %)Shunt error |(%style="width:58px" %)SHE|(% style="width:443px" %)internalerror ofthe shuntcurrent sensor;|(%style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)97 -| (% style="width:196px"%)Settingserror|(% style="width:58px" %)SET|(%style="width:443px" %)|(%style="width:67px" %)|(%style="width:93px" %)|(%style="width:76px" %)|(%style="width:80px" %)|(% style="width:142px" %) |(% style="width:134px" %)98 -| (%style="width:196px" %)WDT reset|(% style="width:58px" %)WDT|(% style="width:443px" %)watchdogtimerresetthe device;|(%style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)99 -| (% style="width:196px"%)Notemperaturesensors |(% style="width:58px" %)NTS|(% style="width:443px" %)the device has no temperature sensorsconnected;|(%style="width:67px"%)•|(%style="width:93px"%)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)100 -| (%style="width:196px" %)Temperaturesensor is shorted |(% style="width:58px" %)TSS|(% style="width:443px" %)some temperature sensorsareshorted;|(%style="width:67px" %)•|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)101 -| (%style="width:196px" %)Spiritoffline|(% style="width:58px"%)SPI|(%style="width:443px"%)connectionwithaSpiritforklift islost;|(% style="width:67px"%) |(% style="width:93px"%)Yes|(% style="width:76px"%)Yes|(%style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)102 -| (% style="width:196px" %)Mount error|(% style="width:58px" %)MNT|(%style="width:443px" %)|(%style="width:67px" %)|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)103 -| (%style="width:196px" %)FSerror|(% style="width:58px"%)FSE|(%style="width:443px"%) |(% style="width:67px"%)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)104 -| (% style="width:196px" %)Lowtemperature(CH) |(%style="width:58px"%)LCT|(% style="width:443px"%)temperatureistoo low for charging;|(% style="width:67px" %) |(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)105 -| (% style="width:196px" %)High temperature(CH) |(% style="width:58px" %)HCT|(%style="width:443px" %)temperature is too high for charging;|(%style="width:67px" %)|(% style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)106 -| (% style="width:196px" %)Unallowable charging |(% style="width:58px" %)UCH|(% style="width:443px" %)charging thebattery through the discharging contactor;|(%style="width:67px" %)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)107 -| (%style="width:196px" %)Stuck contactor|(%style="width:58px"%)STC|(% style="width:443px"%) |(% style="width:67px"%)•|(%style="width:93px" %)Yes|(%style="width:76px" %)Yes|(%style="width:80px"%)Yes|(% style="width:142px" %) |(% style="width:134px" %)108 -| (% style="width:196px"%)CH contactorfeedbackerror|(%style="width:58px" %)CCF|(% style="width:443px"%)thecontrolsignalsforthechargingcontactorandthecontactorfeedbackdiffer;|(% style="width:67px" %)•|(%style="width:93px" %)|(%style="width:76px" %)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %)109 -| (%style="width:196px"%)DCH contactor feedback error |(% style="width:58px" %)DCF|(%style="width:443px" %)the controlsignals forhedischargingcontactorandthecontactorfeedback differ;|(%style="width:67px"%)•|(% style="width:93px" %) |(% style="width:76px"%)Yes|(% style="width:80px" %) |(% style="width:142px" %) |(% style="width:134px" %)110 -| (% style="width:196px" %)Insulationfault;|(%style="width:58px"%)INF|(% style="width:443px"%) |(% style="width:67px"%)•|(%style="width:93px"%)Yes|(% style="width:76px"%)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)111 -| (% style="width:196px" %)PCH contactor feedback error |(% style="width:58px" %)PCF|(% style="width:443px" %)the control signalsfor theprecharging contactorand the contactor feedback differ;|(%style="width:67px" %)•|(%style="width:93px" %)|(%style="width:76px" %)Yes|(%style="width:80px" %)|(% style="width:142px" %) |(% style="width:134px" %)112 -| (% style="width:196px" %)CH/DCH contactorfeedback error |(% style="width:58px"%)CDF|(% style="width:443px" %)thecontrol signals forthecharging/discharging contactor and the contactor feedback differ;|(% style="width:67px" %)•|(%style="width:93px" %)|(%style="width:76px" %)Yes|(%style="width:80px" %)|(% style="width:142px" %) |(% style="width:134px" %)113 -| (% style="width:196px" %)Maincontactorfeedback error |(% style="width:58px" %)MCF|(% style="width:443px" %)the control signalsfor themain contactorandthecontactorfeedback differ;|(% style="width:67px" %)•|(% style="width:93px" %) |(%style="width:76px" %)Yes|(% style="width:80px" %)|(% style="width:142px" %) |(% style="width:134px" %)114 -| (% style="width:196px"%)Contactorfeedback error|(% style="width:58px"%)CFE|(% style="width:443px" %)Failureof one ofthecontactorsfeedbacksignal. Which contactor isfailed can be |(%style="width:67px" %)|(% style="width:93px" %)Yes|(% style="width:76px" %) |(%style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)115 -| (% style="width:196px"%)Generalerror|(%style="width:58px"%)GE|(%style="width:443px"%) |(% style="width:67px"%)|(%style="width:93px"%)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)116 -| (% style="width:196px" %)High voltage fault|(% style="width:58px" %)HVF|(% style="width:443px" %)failureof high voltage measuringcircuits;|(%style="width:67px" %)•|(% style="width:93px" %) |(%style="width:76px" %)|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)117 -| (% style="width:196px" %)Powerswitcherror|(%style="width:58px"%)PSE|(%style="width:443px" %)short circuit in contactorcoil control circuitorpowerswitchverheating;|(% style="width:67px" %)•|(% style="width:93px" %) |(%style="width:76px" %)|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)118 -| (% style="width:196px" %)HVIL error |(% style="width:58px"%)HE|(%style="width:443px"%)breakage ofhigh-voltageinterlockcurrentloop;|(%style="width:67px" %)•|(% style="width:93px" %) |(%style="width:76px" %)|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)119 -| (% style="width:196px" %)Precharge error |(% style="width:58px" %)PE|(% style="width:443px" %)capacitive load pre-chargeprocess did not end during the estimated time;|(%style="width:67px" %)|(%style="width:93px" %)Yes|(% style="width:76px" %)Yes|(% style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)120 -| (% style="width:196px" %)Powerfault|(% style="width:58px" %)PF|(% style="width:443px" %)external devicespower supply error: currentsensors,HVIL, BMS Logic or CAN2 (int)bus powereddevices;|(% style="width:67px" %)•|(%style="width:93px" %)|(% style="width:76px" %) |(%style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)121 -| (%style="width:196px" %)Current limit error |(%style="width:58px"%)CLE|(% style="width:443px" %)chargingor dischargingcurrent ismorehanlimitcalculated by Chargemap or Dischargemap.|(% style="width:67px" %)|(% style="width:93px" %)Yes|(% style="width:76px" %) |(%style="width:80px" %)Yes|(% style="width:142px" %) |(% style="width:134px" %)90 +|ADC error |ADC|current cannot be measured;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 91 +|Battery cover error |BC|battery cover is open;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 92 +|Cell count error |CEL|number of cells does not match the specified value;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 93 +|CH contactor cycles error |CCC|switching frequency of the charging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 94 +|CH contactor feedback error |CCF|the control signals for the charging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %) 95 +|CH/DCH contactor feedback error |CDF|the control signals for the charging/discharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %) 96 +|Combilift offline |COM|connection with a Combilift forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 97 +|Contactor feedback error|CFE|Failure of one of the contactors feedback signal. Which contactor is failed can be | |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %) 98 +|Critical error|CER| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 99 +|Crown error |CRO|connection with a Crown forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 100 +|Current limit error |CLE|charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |Yes|(% style="width:142px" %) |(% style="width:134px" %) 101 +|Current sensor error |CSE|error in the current sensor circuit;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 102 +|DCH contactor cycles error |DCC|switching frequency of the discharging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 103 +|DCH contactor feedback error |DCF|the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %) 104 +|FS error|FSE| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 105 +|General error|GE| | |Yes*|Yes*|Yes|(% style="width:142px" %) |(% style="width:134px" %) 106 +|High contactor temperature|CHT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 107 +|High humidity |HH|humidity of the battery is increased;| | |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 108 +|High Logic temperature |LHT|at least one of the Logic devices is overheated;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 109 +|High temperature (CH) |HCT|temperature is too high for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 110 +|High temperature (DCH) |HDT|temperature is too high for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 111 +|High voltage fault |HVF|failure of high voltage measuring circuits;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 112 +|HVIL error |HE|breakage of high-voltage interlock current loop;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 113 +|HYG offline |HYG|connection with a HYG forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 114 +|Insulation fault;|INF| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 115 +|Logic count error|LOG| | | | | |(% style="width:142px" %) |(% style="width:134px" %) 116 +|Logic offline |LOF|at least one of the Logic devices is offline;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 117 +|Low temperature (CH) |LCT|temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 118 +|Low temperature (DCH) |LDT|temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 119 +|Main contactor feedback error |MCF|the control signals for the main contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %) 120 +|Mount error|MNT| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 121 +|Need acknowledge |ACK|there is an unacknowledged error in Error journal;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 122 +|No temperature sensors |NTS|the device has no temperature sensors connected;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 123 +|Overcurrent|OC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 124 +|Overvoltage|OV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 125 +|PCH contactor feedback error |PCF|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes| |(% style="width:142px" %) |(% style="width:134px" %) 126 +|Power fault |PF|external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 127 +|Power switch error |PSE|short circuit in contactor coil control circuit or power switch overheating;|•| | |Yes|(% style="width:142px" %) |(% style="width:134px" %) 128 +|Precharge error |PE|capacitive load pre-charge process did not end during the estimated time;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 129 +|Settings error|SET| | | | | |(% style="width:142px" %) |(% style="width:134px" %) 130 +|Short circuit|SHC| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 131 +|Shunt error |SHE|internal error of the shunt current sensor;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 132 +|Shunt offline |SHO|connection with the shunt current sensor is lost;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 133 +|Spirit offline |SPI|connection with a Spirit forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 134 +|Stuck contactor|STC| |•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 135 +|Temperature sensor is shorted |TSS|some temperature sensors are shorted;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 136 +|Unallowable charging |UCH|charging the battery through the discharging contactor;| |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 137 +|Undervoltage|UV| | |Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 138 +|Water |WA|there is water in the battery enclosure;|•| |Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 139 +|WDT reset |WDT|watchdog timer reset the device;|•|Yes|Yes|Yes|(% style="width:142px" %) |(% style="width:134px" %) 122 122 123 - 141 +~* signal can be assigned to a discrete output and relay.