Last modified by Admin on 2025/03/03 15:20

From version 8.22
edited by Admin
on 2025/01/30 14:02
Change comment: There is no comment for this version
To version 8.20
edited by Admin
on 2025/01/30 14:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -25,13 +25,11 @@
25 25  |(% style="width:198px" %)CH/DCH contactor feedback |(% style="width:60px" %)CDF|(% style="width:483px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
26 26  |(% style="width:198px" %)Main contactor feedback |(% style="width:60px" %)MCF|(% style="width:483px" %) a signal from main contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
27 27  |(% style="width:198px" %)Interlock |(% style="width:60px" %) |(% style="width:483px" %) a signal from interlock loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
28 -|(% style="width:198px" %)Fuse 1|(% style="width:60px" %)F1|(% style="width:483px" %) signal from fuse 1;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
29 -|(% style="width:198px" %)Fuse 2|(% style="width:60px" %)F2|(% style="width:483px" %)signal from fuse 2;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
30 -|(% style="width:198px" %)Fuse 3 |(% style="width:60px" %)F3|(% style="width:483px" %)signal from fuse 3;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
28 +|(% style="width:198px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:60px" %)F1, F2, F3|(% style="width:483px" %) signals from fuses;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
31 31  |(% style="width:198px" %)Circuit breaker status |(% style="width:60px" %)CBS|(% style="width:483px" %) status of protection disconnector;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
32 -|(% style="width:198px" %)Balancing request |(% style="width:60px" %)BR|(% style="width:483px" %) a request to balance the cells;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
33 -|(% style="width:198px" %)Close Main contactor |(% style="width:60px" %)CMC|(% style="width:483px" %) a request to close the main contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
34 -|(% style="width:198px" %)Close External 1 |(% style="width:60px" %)CE1|(% style="width:483px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
30 +|(% style="width:198px" %)Balancing request |(% style="width:60px" %) |(% style="width:483px" %) a request to balance the cells;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
31 +|(% style="width:198px" %)Close Main contactor |(% style="width:60px" %) |(% style="width:483px" %) a request to close the main contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
32 +|(% style="width:198px" %)Close External 1 |(% style="width:60px" %) |(% style="width:483px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)
35 35  
36 36  === List of internal states ===
37 37  
... ... @@ -40,21 +40,21 @@
40 40  (% style="width:1277px" %)
41 41  |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus**
42 42  |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3**
43 -|(% style="width:201px" %)Low SOC |(% style="width:55px" %)LOS|(% style="width:531px" %) a signal corresponding the low SOC of the battery;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
44 -|(% style="width:201px" %)High charging current |(% style="width:55px" %)HCC|(% style="width:531px" %) charging current is high;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
41 +|(% style="width:201px" %)Low SOC |(% style="width:55px" %) |(% style="width:531px" %) a signal corresponding the low SOC of the battery;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
42 +|(% style="width:201px" %)High charging current |(% style="width:55px" %) |(% style="width:531px" %) charging current is high;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
45 45  |(% style="width:201px" %)Main contactor |(% style="width:55px" %) |(% style="width:531px" %) state of the main contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
46 -|(% style="width:201px" %)Charging |(% style="width:55px" %)CH|(% style="width:531px" %) state of the charging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
47 -|(% style="width:201px" %)Allow charging |(% style="width:55px" %)ACH|(% style="width:531px" %) a signal for a charger to start charging;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
48 -|(% style="width:201px" %)Charging current present |(% style="width:55px" %)CCP|(% style="width:531px" %) the presence of the charging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
49 -|(% style="width:201px" %)Precharging |(% style="width:55px" %)PRE|(% style="width:531px" %) state of the precharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
50 -|(% style="width:201px" %)Discharging |(% style="width:55px" %)DCH|(% style="width:531px" %) state of the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
51 -|(% style="width:201px" %)Discharging current present |(% style="width:55px" %)DCP|(% style="width:531px" %) the presence of the discharging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
44 +|(% style="width:201px" %)Charging |(% style="width:55px" %) |(% style="width:531px" %) state of the charging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
45 +|(% style="width:201px" %)Allow charging |(% style="width:55px" %) |(% style="width:531px" %) a signal for a charger to start charging;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
46 +|(% style="width:201px" %)Charging current present |(% style="width:55px" %) |(% style="width:531px" %) the presence of the charging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
47 +|(% style="width:201px" %)Precharging |(% style="width:55px" %) |(% style="width:531px" %) state of the precharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
48 +|(% style="width:201px" %)Discharging |(% style="width:55px" %) |(% style="width:531px" %) state of the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
49 +|(% style="width:201px" %)Discharging current present |(% style="width:55px" %) |(% style="width:531px" %) the presence of the discharging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
52 52  |(% style="width:201px" %)Discharging (AUX) |(% style="width:55px" %) |(% style="width:531px" %) state of the auxiliary discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
53 53  |(% style="width:201px" %)Power down ACK |(% style="width:55px" %) |(% style="width:531px" %) an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
54 54  |(% style="width:201px" %)Charging/discharging|(% style="width:55px" %) |(% style="width:531px" %)state of the charging/discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
55 -|(% style="width:201px" %)Heater |(% style="width:55px" %)HEA|(% style="width:531px" %) a command to turn on a heater;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
56 -|(% style="width:201px" %)Cooler |(% style="width:55px" %)COO|(% style="width:531px" %) a command to turn on a cooler;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
57 -|(% style="width:201px" %)Balancing 1 |(% style="width:55px" %)BA1|(% style="width:531px" %) balancing the first series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
53 +|(% style="width:201px" %)Heater |(% style="width:55px" %) |(% style="width:531px" %) a command to turn on a heater;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
54 +|(% style="width:201px" %)Cooler |(% style="width:55px" %) |(% style="width:531px" %) a command to turn on a cooler;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
55 +|(% style="width:201px" %)Balancing 1 |(% style="width:55px" %) |(% style="width:531px" %) balancing the first series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
58 58  |(% style="width:201px" %)Balancing 2 |(% style="width:55px" %) |(% style="width:531px" %) balancing the second series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
59 59  |(% style="width:201px" %)Ready to charge |(% style="width:55px" %) |(% style="width:531px" %) the battery is ready to be charged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)
60 60  |(% style="width:201px" %)Ready to discharge |(% style="width:55px" %) |(% style="width:531px" %) the battery is ready to be discharged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)