Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -25,11 +25,13 @@ 25 25 |(% style="width:198px" %)CH/DCH contactor feedback |(% style="width:60px" %)CDF|(% style="width:483px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 26 26 |(% style="width:198px" %)Main contactor feedback |(% style="width:60px" %)MCF|(% style="width:483px" %) a signal from main contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 27 27 |(% style="width:198px" %)Interlock |(% style="width:60px" %) |(% style="width:483px" %) a signal from interlock loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 28 -|(% style="width:198px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:60px" %)F1, F2, F3|(% style="width:483px" %) signals from fuses;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 28 +|(% style="width:198px" %)Fuse 1|(% style="width:60px" %)F1|(% style="width:483px" %) signal from fuse 1;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 29 +|(% style="width:198px" %)Fuse 2|(% style="width:60px" %)F2|(% style="width:483px" %)signal from fuse 2;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 30 +|(% style="width:198px" %)Fuse 3 |(% style="width:60px" %)F3|(% style="width:483px" %)signal from fuse 3;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 29 29 |(% style="width:198px" %)Circuit breaker status |(% style="width:60px" %)CBS|(% style="width:483px" %) status of protection disconnector;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 30 -|(% style="width:198px" %)Balancing request |(% style="width:60px" %) 31 -|(% style="width:198px" %)Close Main contactor |(% style="width:60px" %) 32 -|(% style="width:198px" %)Close External 1 |(% style="width:60px" %) 32 +|(% style="width:198px" %)Balancing request |(% style="width:60px" %)BR|(% style="width:483px" %) a request to balance the cells;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 33 +|(% style="width:198px" %)Close Main contactor |(% style="width:60px" %)CMC|(% style="width:483px" %) a request to close the main contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 34 +|(% style="width:198px" %)Close External 1 |(% style="width:60px" %)CE1|(% style="width:483px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 33 33 34 34 === List of internal states === 35 35 ... ... @@ -38,7 +38,7 @@ 38 38 (% style="width:1277px" %) 39 39 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 40 40 |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** 41 -|(% style="width:201px" %)Low SOC |(% style="width:55px" %) 43 +|(% style="width:201px" %)Low SOC |(% style="width:55px" %)LOS|(% style="width:531px" %) a signal corresponding the low SOC of the battery;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 42 42 |(% style="width:201px" %)High charging current |(% style="width:55px" %) |(% style="width:531px" %) charging current is high;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 43 43 |(% style="width:201px" %)Main contactor |(% style="width:55px" %) |(% style="width:531px" %) state of the main contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 44 44 |(% style="width:201px" %)Charging |(% style="width:55px" %) |(% style="width:531px" %) state of the charging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %)