Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,107 +9,108 @@ 9 9 Here is the list of available input signals of BMS Main 3. 10 10 11 11 (% style="width:1274px" %) 12 -|(% colspan="1" rowspan="2" style="width:198px" %)**Name**|(% colspan="1"rowspan="2" style="width:443px" %)**Description**|(% colspan="3" rowspan="1" style="width:254px" %)**Compability**|(% colspan="1" rowspan="2" style="width:143px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:140px" %)**Modbus**|(% colspan="1" rowspan="2" style="width:86px" %)**Abbreviation**13 -|(% style="width:9 4px" %)**Mini S / Mini**|(% style="width:77px" %)**Main 2.1**|(% style="width:81px" %)**Main 3**14 -|(% style="width:198px" %)Battery cover |(% style="width: 443px" %) a signal from the battery cover;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)15 -|(% style="width:198px" %)Charger connected |(% style="width: 443px" %) a signal indicating that charger is connected;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)16 -|(% style="width:198px" %)Power up/down request |(% style="width: 443px" %) a request to power down the device;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)17 -|(% style="width:198px" %)Inhibit charging |(% style="width: 443px" %) a command to open the charging contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)18 -|(% style="width:198px" %)Inhibit discharging |(% style="width: 443px" %) a command to open the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)19 -|(% style="width:198px" %)CH contactor feedback |(% style="width: 443px" %) a signal from charging contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)20 -|(% style="width:198px" %)DCH contactor feedback |(% style="width: 443px" %) a signal from discharging contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)21 -|(% style="width:198px" %)Insulation status |(% style="width: 443px" %) a signal from an insulation monitoring device;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)22 -|(% style="width:198px" %)Charge request |(% style="width: 443px" %) a request to close the charging contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)23 -|(% style="width:198px" %)Discharge request |(% style="width: 443px" %) a request to close the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)24 -|(% style="width:198px" %)PCH contactor feedback |(% style="width: 443px" %) a signal from precharging contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)25 -|(% style="width:198px" %)CH/DCH contactor feedback |(% style="width: 443px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)26 -|(% style="width:198px" %)Main contactor feedback |(% style="width: 443px" %) a signal from main contactor feedback loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)27 -|(% style="width:198px" %)Interlock |(% style="width: 443px" %) a signal from interlock loop;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)28 -|(% style="width:198px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width: 443px" %) signals from fuses;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)29 -|(% style="width:198px" %)Circuit breaker status |(% style="width: 443px" %) status of protection disconnector;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)30 -|(% style="width:198px" %)Balancing request |(% style="width: 443px" %) a request to balance the cells;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)31 -|(% style="width:198px" %)Close Main contactor |(% style="width: 443px" %) a request to close the main contactor;|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)32 -|(% style="width:198px" %)Close External 1 |(% style="width: 443px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:94px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %)|(% style="width:86px" %)12 +|=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% rowspan="2" style="width: 53px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 500px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 248px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 143px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**Modbus** 13 +|=(% style="width: 98px;" %)**Mini S / Mini**|=(% style="width: 77px;" %)**Main 2.1**|=(% style="width: 81px;" %)**Main 3** 14 +|(% style="width:198px" %)Battery cover |(% style="width:53px" %) |(% style="width:500px" %) a signal from the battery cover;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 15 +|(% style="width:198px" %)Charger connected |(% style="width:53px" %) |(% style="width:500px" %) a signal indicating that charger is connected;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 16 +|(% style="width:198px" %)Power up/down request |(% style="width:53px" %) |(% style="width:500px" %) a request to power down the device;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 17 +|(% style="width:198px" %)Inhibit charging |(% style="width:53px" %) |(% style="width:500px" %) a command to open the charging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 18 +|(% style="width:198px" %)Inhibit discharging |(% style="width:53px" %) |(% style="width:500px" %) a command to open the discharging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 19 +|(% style="width:198px" %)CH contactor feedback |(% style="width:53px" %) |(% style="width:500px" %) a signal from charging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 20 +|(% style="width:198px" %)DCH contactor feedback |(% style="width:53px" %) |(% style="width:500px" %) a signal from discharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 21 +|(% style="width:198px" %)Insulation status |(% style="width:53px" %) |(% style="width:500px" %) a signal from an insulation monitoring device;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 22 +|(% style="width:198px" %)Charge request |(% style="width:53px" %) |(% style="width:500px" %) a request to close the charging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 23 +|(% style="width:198px" %)Discharge request |(% style="width:53px" %) |(% style="width:500px" %) a request to close the discharging contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 24 +|(% style="width:198px" %)PCH contactor feedback |(% style="width:53px" %) |(% style="width:500px" %) a signal from precharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 25 +|(% style="width:198px" %)CH/DCH contactor feedback |(% style="width:53px" %) |(% style="width:500px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 26 +|(% style="width:198px" %)Main contactor feedback |(% style="width:53px" %) |(% style="width:500px" %) a signal from main contactor feedback loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 27 +|(% style="width:198px" %)Interlock |(% style="width:53px" %) |(% style="width:500px" %) a signal from interlock loop;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 28 +|(% style="width:198px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:53px" %) |(% style="width:500px" %) signals from fuses;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 29 +|(% style="width:198px" %)Circuit breaker status |(% style="width:53px" %) |(% style="width:500px" %) status of protection disconnector;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 30 +|(% style="width:198px" %)Balancing request |(% style="width:53px" %) |(% style="width:500px" %) a request to balance the cells;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 31 +|(% style="width:198px" %)Close Main contactor |(% style="width:53px" %) |(% style="width:500px" %) a request to close the main contactor;|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 32 +|(% style="width:198px" %)Close External 1 |(% style="width:53px" %) |(% style="width:500px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:98px" %)Yes|(% style="width:77px" %)Yes|(% style="width:81px" %)Yes|(% style="width:143px" %) |(% style="width:140px" %) 33 33 34 34 === List of internal states === 35 35 36 36 Here is the list of available internal states of BMS Main 3. 37 37 38 -(% style="width:1 158px" %)39 -|(% colspan="1" style="width:21 6px" %)**Name**|(% colspan="1" style="width:322px" %)**Description**|(% colspan="1" style="width:97px" %)**Compability**|(%style="width:65px"%) |(%style="width:56px" %) |(% colspan="4" rowspan="1" style="width:408px" %)**Outputby**40 -| (% colspan="1" style="width:216px" %) |(%colspan="1" style="width:322px"%)**Description**|(% style="width:97px" %)**Mini S / Mini**|(% style="width:65px" %)**Main 2.1**|(% style="width:56px" %)**Main 3**|(% style="width:227px" %)**Discrete output**|(% style="width:60px" %)**Switch**|(% style="width:52px" %)**CAN**|(% style="width:70px" %)**Modbus**41 -|Low SOC |(% style="width:3 22px" %) a signal corresponding the low SOC of the battery;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %)|(% style="width:70px" %)42 -| High charging current |(% style="width:322px" %) charging currentis high;|(% style="width:97px" %) |(% style="width:65px" %) |(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)43 -| Main contactor |(% style="width:322px" %)state of the main contactor;|(% style="width:97px" %) |(% style="width:65px" %) |(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)44 -| Charging |(% style="width:322px" %)state of the chargingcontactor;|(% style="width:97px" %) |(% style="width:65px" %) |(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)45 -|Allow charging |(% style="width:3 22px" %) a signal for a charger to start charging;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %)|(% style="width:70px" %)46 -|Charging current present |(% style="width:3 22px" %) the presence of the charging current;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %)|(% style="width:70px" %)47 -| Precharging |(% style="width:322px" %)state of the prechargingcontactor;|(% style="width:97px" %) |(% style="width:65px" %) |(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)48 -| Discharging |(% style="width:322px" %)state of the dischargingcontactor;|(% style="width:97px" %) |(% style="width:65px" %) |(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)49 -|Discharging current present |(% style="width:3 22px" %) the presence of the discharging current;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %)|(% style="width:70px" %)50 -|Discharging (AUX) |(% style="width:3 22px" %) state of the auxiliary discharging contactor;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %)|(% style="width:70px" %)51 -|Power down ACK |(% style="width:3 22px" %) an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %)|(% style="width:70px" %)52 -|Charging/discharging|(% style="width:3 22px" %)state of the charging/discharging contactor;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %)|(% style="width:70px" %)53 -| Heater |(% style="width:322px" %)a command to turn on a heater;|(% style="width:97px" %) |(% style="width:65px" %) |(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)54 -| Cooler |(% style="width:322px" %)a command toturn on a cooler;|(% style="width:97px" %) |(% style="width:65px" %) |(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)55 -| Balancing 1 |(% style="width:322px" %)balancingthefirst series of cells;|(% style="width:97px" %) |(% style="width:65px" %) |(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)56 -| Balancing 2 |(% style="width:322px" %)balancingthesecond series of cells;|(% style="width:97px" %) |(% style="width:65px" %) |(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)57 -| Ready to charge |(% style="width:322px" %)thebattery is ready tobecharged;|(% style="width:97px" %) |(% style="width:65px" %) |(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)58 -| Ready to discharge |(% style="width:322px" %)thebattery is ready tobedischarged;|(% style="width:97px" %) |(% style="width:65px" %) |(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)59 -| Power up |(% style="width:322px" %)an indication of BMS powerstatus;|(% style="width:97px" %) |(% style="width:65px" %) |(% style="width:56px" %)227px" %)•|(% style="width:60px" %)•|(% style="width:52px" %) |(% style="width:70px" %)60 -|General error |(% style="width:3 22px" %) state of the configurable (general) error;|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)60px" %) |(% style="width:52px" %)|(% style="width:70px" %)61 -|External 1 |(% style="width:3 22px" %) a signal that activates by the remote request.|(% style="width:97px" %)|(% style="width:65px" %)|(% style="width:56px" %)227px" %)60px" %) |(% style="width:52px" %)|(% style="width:70px" %)38 +(% style="width:1277px" %) 39 +|=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% rowspan="2" style="width: 55px;" %)**Abbr.**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** 40 +|=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 75px;" %)**Main 2.1**|=(% style="width: 84px;" %)**Main 3** 41 +|(% style="width:201px" %)Low SOC |(% style="width:55px" %) |(% style="width:531px" %) a signal corresponding the low SOC of the battery;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 42 +|(% style="width:201px" %)High charging current |(% style="width:55px" %) |(% style="width:531px" %) charging current is high;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 43 +|(% style="width:201px" %)Main contactor |(% style="width:55px" %) |(% style="width:531px" %) state of the main contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 44 +|(% style="width:201px" %)Charging |(% style="width:55px" %) |(% style="width:531px" %) state of the charging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 45 +|(% style="width:201px" %)Allow charging |(% style="width:55px" %) |(% style="width:531px" %) a signal for a charger to start charging;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 46 +|(% style="width:201px" %)Charging current present |(% style="width:55px" %) |(% style="width:531px" %) the presence of the charging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 47 +|(% style="width:201px" %)Precharging |(% style="width:55px" %) |(% style="width:531px" %) state of the precharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 48 +|(% style="width:201px" %)Discharging |(% style="width:55px" %) |(% style="width:531px" %) state of the discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 49 +|(% style="width:201px" %)Discharging current present |(% style="width:55px" %) |(% style="width:531px" %) the presence of the discharging current;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 50 +|(% style="width:201px" %)Discharging (AUX) |(% style="width:55px" %) |(% style="width:531px" %) state of the auxiliary discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 51 +|(% style="width:201px" %)Power down ACK |(% style="width:55px" %) |(% style="width:531px" %) an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 52 +|(% style="width:201px" %)Charging/discharging|(% style="width:55px" %) |(% style="width:531px" %)state of the charging/discharging contactor;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 53 +|(% style="width:201px" %)Heater |(% style="width:55px" %) |(% style="width:531px" %) a command to turn on a heater;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 54 +|(% style="width:201px" %)Cooler |(% style="width:55px" %) |(% style="width:531px" %) a command to turn on a cooler;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 55 +|(% style="width:201px" %)Balancing 1 |(% style="width:55px" %) |(% style="width:531px" %) balancing the first series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 56 +|(% style="width:201px" %)Balancing 2 |(% style="width:55px" %) |(% style="width:531px" %) balancing the second series of cells;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 57 +|(% style="width:201px" %)Ready to charge |(% style="width:55px" %) |(% style="width:531px" %) the battery is ready to be charged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 58 +|(% style="width:201px" %)Ready to discharge |(% style="width:55px" %) |(% style="width:531px" %) the battery is ready to be discharged;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 59 +|(% style="width:201px" %)Power up |(% style="width:55px" %) |(% style="width:531px" %) an indication of BMS power status;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 60 +|(% style="width:201px" %)General error |(% style="width:55px" %) |(% style="width:531px" %) state of the configurable (general) error;|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 61 +|(% style="width:201px" %)External 1 |(% style="width:55px" %) |(% style="width:531px" %) a signal that activates by the remote request.|(% style="width:94px" %)Yes|(% style="width:75px" %)Yes|(% style="width:84px" %)Yes|(% style="width:140px" %) |(% style="width:142px" %) 62 62 63 63 === List of errors === 64 64 65 65 Here is the list of error of BMS Main 3. 66 66 67 -(% style="width:1177px" %) 68 -|(% style="width:171px" %)**Name **|(% style="width:67px" %)**Abbr.**|(% style="width:501px" %)**Description**|(% style="width:228px" %)**Set up by**|(% style="width:145px" %)**Is a Critical error?**|(% style="width:145px" %) 69 -|(% style="width:171px" %)Overcurrent|(% style="width:67px" %)OC|(% style="width:501px" %) |(% style="width:228px" %)Overcurrent protection|(% style="width:145px" %) |(% style="width:145px" %) 70 -|(% style="width:171px" %)Undervoltage|(% style="width:67px" %)UV|(% style="width:501px" %) |(% style="width:228px" %)Undervoltage protection|(% style="width:145px" %) |(% style="width:145px" %) 71 -|(% style="width:171px" %)Overvoltage|(% style="width:67px" %)OV|(% style="width:501px" %) |(% style="width:228px" %)Overvoltage protection|(% style="width:145px" %) |(% style="width:145px" %) 72 -|(% style="width:171px" %)Low temperature (DCH) |(% style="width:67px" %)LDT|(% style="width:501px" %) temperature is too low for discharging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 73 -|(% style="width:171px" %)High temperature (DCH) |(% style="width:67px" %)HDT|(% style="width:501px" %) temperature is too high for discharging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 74 -|(% style="width:171px" %)Battery cover error |(% style="width:67px" %)BC|(% style="width:501px" %) battery cover is open;|(% style="width:228px" %)Battery cover protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 75 -|(% style="width:171px" %)High humidity |(% style="width:67px" %)HH|(% style="width:501px" %) humidity of the battery is increased;|(% style="width:228px" %)High humidity protection|(% style="width:145px" %) |(% style="width:145px" %) 76 -|(% style="width:171px" %)Water |(% style="width:67px" %)WA|(% style="width:501px" %) there is water in the battery enclosure;|(% style="width:228px" %)Water protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 77 -|(% style="width:171px" %)High Logic temperature |(% style="width:67px" %)LHT|(% style="width:501px" %) at least one of the Logic devices is overheated;|(% style="width:228px" %)Logic high temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 78 -|(% style="width:171px" %)Logic offline |(% style="width:67px" %)LOF|(% style="width:501px" %) at least one of the Logic devices is offline;|(% style="width:228px" %)Logic offline protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 79 -|(% style="width:171px" %)Critical error|(% style="width:67px" %)CRE|(% style="width:501px" %) |(% style="width:228px" %)Critical error|(% style="width:145px" %) |(% style="width:145px" %) 80 -|(% style="width:171px" %)Crown error |(% style="width:67px" %)CRO|(% style="width:501px" %) connection with a Crown forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 81 -|(% style="width:171px" %)Cell count error |(% style="width:67px" %)CEL|(% style="width:501px" %) number of cells does not match the specified value;|(% style="width:228px" %)Cell count protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 82 -|(% style="width:171px" %)HYG offline |(% style="width:67px" %)HYG|(% style="width:501px" %) connection with a HYG forklift is lost;|(% style="width:228px" %)HYG Class I-III truck|(% style="width:145px" %) |(% style="width:145px" %) 83 -|(% style="width:171px" %)Need acknowledge |(% style="width:67px" %) |(% style="width:501px" %) there is an unacknowledged error in Error journal;|(% style="width:228px" %)Error journal|(% style="width:145px" %) |(% style="width:145px" %) 84 -|(% style="width:171px" %)Combilift offline |(% style="width:67px" %) |(% style="width:501px" %) connection with a Combilift forklift is lost;|(% style="width:228px" %)Combilift truck|(% style="width:145px" %) |(% style="width:145px" %) 85 -|(% style="width:171px" %)Short circuit|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)Short circuit protection|(% style="width:145px" %) |(% style="width:145px" %) 86 -|(% style="width:171px" %)High contactor temperature|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)High contactor temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 87 -|(% style="width:171px" %)ADC error |(% style="width:67px" %) |(% style="width:501px" %) current cannot be measured;|(% style="width:228px" %) |(% style="width:145px" %)Yes|(% style="width:145px" %) 88 -|(% style="width:171px" %)Current sensor error |(% style="width:67px" %) |(% style="width:501px" %) error in the current sensor circuit;|(% style="width:228px" %)Current sensor protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 89 -|(% style="width:171px" %)CH contactor cycles error |(% style="width:67px" %) |(% style="width:501px" %) switching frequency of the charging contactor is too high;|(% style="width:228px" %)Charge contactor cycles protection|(% style="width:145px" %) |(% style="width:145px" %) 90 -|(% style="width:171px" %)DCH contactor cycles error |(% style="width:67px" %) |(% style="width:501px" %) switching frequency of the discharging contactor is too high;|(% style="width:228px" %)Discharge contactor cycles protection|(% style="width:145px" %) |(% style="width:145px" %) 91 -|(% style="width:171px" %)Shunt offline |(% style="width:67px" %) |(% style="width:501px" %) connection with the shunt current sensor is lost;|(% style="width:228px" %)Shunt sensor (CAN bus)|(% style="width:145px" %)Yes|(% style="width:145px" %) 92 -|(% style="width:171px" %)Shunt error |(% style="width:67px" %) |(% style="width:501px" %) internal error of the shunt current sensor;|(% style="width:228px" %)Shunt sensor (CAN bus)|(% style="width:145px" %)Yes|(% style="width:145px" %) 93 -|(% style="width:171px" %)WDT reset |(% style="width:67px" %) |(% style="width:501px" %) watchdog timer reset the device;|(% style="width:228px" %)WDT reset protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 94 -|(% style="width:171px" %)No temperature sensors |(% style="width:67px" %) |(% style="width:501px" %) the device has no temperature sensors connected;|(% style="width:228px" %)Temperature sensors protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 95 -|(% style="width:171px" %)Temperature sensor is shorted |(% style="width:67px" %) |(% style="width:501px" %) some temperature sensors are shorted;|(% style="width:228px" %)Temperature sensors protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 96 -|(% style="width:171px" %)Spirit offline |(% style="width:67px" %) |(% style="width:501px" %) connection with a Spirit forklift is lost;|(% style="width:228px" %)Spirit AGV truck|(% style="width:145px" %) |(% style="width:145px" %) 97 -|(% style="width:171px" %)Low temperature (CH) |(% style="width:67px" %) |(% style="width:501px" %) temperature is too low for charging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 98 -|(% style="width:171px" %)High temperature (CH) |(% style="width:67px" %) |(% style="width:501px" %) temperature is too high for charging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 99 -|(% style="width:171px" %)Unallowable charging |(% style="width:67px" %) |(% style="width:501px" %) charging the battery through the discharging contactor;|(% style="width:228px" %)Unallowable charging protection|(% style="width:145px" %) |(% style="width:145px" %) 100 -|(% style="width:171px" %)Stuck contactor|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)Stuck contactor protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 101 -|(% style="width:171px" %)CH contactor feedback error |(% style="width:67px" %) |(% style="width:501px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 102 -|(% style="width:171px" %)DCH contactor feedback error |(% style="width:67px" %) |(% style="width:501px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 103 -|(% style="width:171px" %)Insulation fault;|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)Insulation protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 104 -|(% style="width:171px" %)PCH contactor feedback error |(% style="width:67px" %) |(% style="width:501px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 105 -|(% style="width:171px" %)CH/DCH contactor feedback error |(% style="width:67px" %) |(% style="width:501px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 106 -|(% style="width:171px" %)Main contactor feedback error |(% style="width:67px" %) |(% style="width:501px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:228px" %)Contactor feedback protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 107 -|(% style="width:171px" %)General error|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)General error|(% style="width:145px" %) |(% style="width:145px" %) 108 -|(% style="width:171px" %)High voltage fault |(% style="width:67px" %) |(% style="width:501px" %) failure of high voltage measuring circuits;|(% style="width:228px" %)High voltage controller|(% style="width:145px" %)Yes|(% style="width:145px" %) 109 -|(% style="width:171px" %)Power switch error |(% style="width:67px" %) |(% style="width:501px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:228px" %) |(% style="width:145px" %)Yes|(% style="width:145px" %) 110 -|(% style="width:171px" %)HVIL error |(% style="width:67px" %) |(% style="width:501px" %) breakage of high-voltage interlock current loop;|(% style="width:228px" %)HVIL protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 111 -|(% style="width:171px" %)Precharge error |(% style="width:67px" %) |(% style="width:501px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:228px" %)Precharge controller|(% style="width:145px" %) |(% style="width:145px" %) 112 -|(% style="width:171px" %)Power fault |(% style="width:67px" %) |(% style="width:501px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:228px" %) |(% style="width:145px" %)Yes|(% style="width:145px" %) 113 -|(% style="width:171px" %)Current limit error |(% style="width:67px" %) |(% style="width:501px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:228px" %)Charge current limit protection, Discharge current limit protection|(% style="width:145px" %) |(% style="width:145px" %) 67 +(% style="width:1279px" %) 68 +|(% style="width:201px" %)**Name **|(% style="width:58px" %)**Abbr.**|(% style="width:313px" %)**Description**|(% style="width:316px" %)**Compability**|(% style="width:316px" %) |(% style="width:47px" %)**Is a Critical error?**|(% style="width:145px" %) |(% style="width:226px" %) 69 +|(% style="width:201px" %) |(% style="width:58px" %) |(% style="width:313px" %) |(% style="width:316px" %) |(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 70 +|(% style="width:201px" %)Overcurrent|(% style="width:58px" %)OC|(% style="width:313px" %) |(% style="width:316px" %)Overcurrent protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 71 +|(% style="width:201px" %)Undervoltage|(% style="width:58px" %)UV|(% style="width:313px" %) |(% style="width:316px" %)Undervoltage protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 72 +|(% style="width:201px" %)Overvoltage|(% style="width:58px" %)OV|(% style="width:313px" %) |(% style="width:316px" %)Overvoltage protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 73 +|(% style="width:201px" %)Low temperature (DCH) |(% style="width:58px" %)LDT|(% style="width:313px" %) temperature is too low for discharging;|(% style="width:316px" %)Low temperature protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 74 +|(% style="width:201px" %)High temperature (DCH) |(% style="width:58px" %)HDT|(% style="width:313px" %) temperature is too high for discharging;|(% style="width:316px" %)High temperature protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 75 +|(% style="width:201px" %)Battery cover error |(% style="width:58px" %)BC|(% style="width:313px" %) battery cover is open;|(% style="width:316px" %)Battery cover protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 76 +|(% style="width:201px" %)High humidity |(% style="width:58px" %)HH|(% style="width:313px" %) humidity of the battery is increased;|(% style="width:316px" %)High humidity protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 77 +|(% style="width:201px" %)Water |(% style="width:58px" %)WA|(% style="width:313px" %) there is water in the battery enclosure;|(% style="width:316px" %)Water protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 78 +|(% style="width:201px" %)High Logic temperature |(% style="width:58px" %)LHT|(% style="width:313px" %) at least one of the Logic devices is overheated;|(% style="width:316px" %)Logic high temperature protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 79 +|(% style="width:201px" %)Logic offline |(% style="width:58px" %)LOF|(% style="width:313px" %) at least one of the Logic devices is offline;|(% style="width:316px" %)Logic offline protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 80 +|(% style="width:201px" %)Critical error|(% style="width:58px" %)CRE|(% style="width:313px" %) |(% style="width:316px" %)Critical error|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 81 +|(% style="width:201px" %)Crown error |(% style="width:58px" %)CRO|(% style="width:313px" %) connection with a Crown forklift is lost;|(% style="width:316px" %) |(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 82 +|(% style="width:201px" %)Cell count error |(% style="width:58px" %)CEL|(% style="width:313px" %) number of cells does not match the specified value;|(% style="width:316px" %)Cell count protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 83 +|(% style="width:201px" %)HYG offline |(% style="width:58px" %)HYG|(% style="width:313px" %) connection with a HYG forklift is lost;|(% style="width:316px" %)HYG Class I-III truck|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 84 +|(% style="width:201px" %)Need acknowledge |(% style="width:58px" %) |(% style="width:313px" %) there is an unacknowledged error in Error journal;|(% style="width:316px" %)Error journal|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 85 +|(% style="width:201px" %)Combilift offline |(% style="width:58px" %) |(% style="width:313px" %) connection with a Combilift forklift is lost;|(% style="width:316px" %)Combilift truck|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 86 +|(% style="width:201px" %)Short circuit|(% style="width:58px" %) |(% style="width:313px" %) |(% style="width:316px" %)Short circuit protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 87 +|(% style="width:201px" %)High contactor temperature|(% style="width:58px" %) |(% style="width:313px" %) |(% style="width:316px" %)High contactor temperature protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 88 +|(% style="width:201px" %)ADC error |(% style="width:58px" %) |(% style="width:313px" %) current cannot be measured;|(% style="width:316px" %) |(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 89 +|(% style="width:201px" %)Current sensor error |(% style="width:58px" %) |(% style="width:313px" %) error in the current sensor circuit;|(% style="width:316px" %)Current sensor protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 90 +|(% style="width:201px" %)CH contactor cycles error |(% style="width:58px" %) |(% style="width:313px" %) switching frequency of the charging contactor is too high;|(% style="width:316px" %)Charge contactor cycles protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 91 +|(% style="width:201px" %)DCH contactor cycles error |(% style="width:58px" %) |(% style="width:313px" %) switching frequency of the discharging contactor is too high;|(% style="width:316px" %)Discharge contactor cycles protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 92 +|(% style="width:201px" %)Shunt offline |(% style="width:58px" %) |(% style="width:313px" %) connection with the shunt current sensor is lost;|(% style="width:316px" %)Shunt sensor (CAN bus)|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 93 +|(% style="width:201px" %)Shunt error |(% style="width:58px" %) |(% style="width:313px" %) internal error of the shunt current sensor;|(% style="width:316px" %)Shunt sensor (CAN bus)|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 94 +|(% style="width:201px" %)WDT reset |(% style="width:58px" %) |(% style="width:313px" %) watchdog timer reset the device;|(% style="width:316px" %)WDT reset protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 95 +|(% style="width:201px" %)No temperature sensors |(% style="width:58px" %) |(% style="width:313px" %) the device has no temperature sensors connected;|(% style="width:316px" %)Temperature sensors protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 96 +|(% style="width:201px" %)Temperature sensor is shorted |(% style="width:58px" %) |(% style="width:313px" %) some temperature sensors are shorted;|(% style="width:316px" %)Temperature sensors protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 97 +|(% style="width:201px" %)Spirit offline |(% style="width:58px" %) |(% style="width:313px" %) connection with a Spirit forklift is lost;|(% style="width:316px" %)Spirit AGV truck|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 98 +|(% style="width:201px" %)Low temperature (CH) |(% style="width:58px" %) |(% style="width:313px" %) temperature is too low for charging;|(% style="width:316px" %)Low temperature protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 99 +|(% style="width:201px" %)High temperature (CH) |(% style="width:58px" %) |(% style="width:313px" %) temperature is too high for charging;|(% style="width:316px" %)High temperature protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 100 +|(% style="width:201px" %)Unallowable charging |(% style="width:58px" %) |(% style="width:313px" %) charging the battery through the discharging contactor;|(% style="width:316px" %)Unallowable charging protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 101 +|(% style="width:201px" %)Stuck contactor|(% style="width:58px" %) |(% style="width:313px" %) |(% style="width:316px" %)Stuck contactor protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 102 +|(% style="width:201px" %)CH contactor feedback error |(% style="width:58px" %) |(% style="width:313px" %) the control signals for the charging contactor and the contactor feedback differ;|(% style="width:316px" %)Contactor feedback protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 103 +|(% style="width:201px" %)DCH contactor feedback error |(% style="width:58px" %) |(% style="width:313px" %) the control signals for the discharging contactor and the contactor feedback differ;|(% style="width:316px" %)Contactor feedback protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 104 +|(% style="width:201px" %)Insulation fault;|(% style="width:58px" %) |(% style="width:313px" %) |(% style="width:316px" %)Insulation protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 105 +|(% style="width:201px" %)PCH contactor feedback error |(% style="width:58px" %) |(% style="width:313px" %) the control signals for the precharging contactor and the contactor feedback differ;|(% style="width:316px" %)Contactor feedback protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 106 +|(% style="width:201px" %)CH/DCH contactor feedback error |(% style="width:58px" %) |(% style="width:313px" %) the control signals for the charging/discharging contactor and the contactor feedback differ;|(% style="width:316px" %)Contactor feedback protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 107 +|(% style="width:201px" %)Main contactor feedback error |(% style="width:58px" %) |(% style="width:313px" %) the control signals for the main contactor and the contactor feedback differ;|(% style="width:316px" %)Contactor feedback protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 108 +|(% style="width:201px" %)General error|(% style="width:58px" %) |(% style="width:313px" %) |(% style="width:316px" %)General error|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 109 +|(% style="width:201px" %)High voltage fault |(% style="width:58px" %) |(% style="width:313px" %) failure of high voltage measuring circuits;|(% style="width:316px" %)High voltage controller|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 110 +|(% style="width:201px" %)Power switch error |(% style="width:58px" %) |(% style="width:313px" %) short circuit in contactor coil control circuit or power switch overheating;|(% style="width:316px" %) |(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 111 +|(% style="width:201px" %)HVIL error |(% style="width:58px" %) |(% style="width:313px" %) breakage of high-voltage interlock current loop;|(% style="width:316px" %)HVIL protection|(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 112 +|(% style="width:201px" %)Precharge error |(% style="width:58px" %) |(% style="width:313px" %) capacitive load pre-charge process did not end during the estimated time;|(% style="width:316px" %)Precharge controller|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 113 +|(% style="width:201px" %)Power fault |(% style="width:58px" %) |(% style="width:313px" %) external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|(% style="width:316px" %) |(% style="width:316px" %) |(% style="width:47px" %)Yes|(% style="width:145px" %) |(% style="width:226px" %) 114 +|(% style="width:201px" %)Current limit error |(% style="width:58px" %) |(% style="width:313px" %) charging or discharging current is more than limit calculated by Charge map or Discharge map.|(% style="width:316px" %)Charge current limit protection, Discharge current limit protection|(% style="width:316px" %) |(% style="width:47px" %) |(% style="width:145px" %) |(% style="width:226px" %) 114 114 115 115