Last modified by Admin on 2026/04/27 14:42

From version 51.1
edited by Admin
on 2026/04/27 14:42
Change comment: There is no comment for this version
To version 50.1
edited by Admin
on 2026/02/18 16:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -109,9 +109,7 @@
109 109  |(% style="width:225px" %)General error|(% style="width:426px" %)Special configurable error depending on other errors|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %)Yes*|(% style="text-align:center; width:80px" %)Yes*|(% style="text-align:center; width:66px" %)Yes*|(% style="width:111px" %)General error|(% style="width:49px" %)GE|(% style="width:166px" %)0x4021 sub 0x00, bit 13|(% style="width:159px" %)0x200E-0x200F, bit 13
110 110  |(% style="width:225px" %)High contactor temperature|(% style="width:426px" %)Temperature of a contactor is too high|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)Hi. cont. temp.|(% style="width:49px" %)HCT|(% style="width:166px" %)0x4020 sub 0x00, bit 17|(% style="width:159px" %)0x2007-0x2008, bit 17
111 111  |(% style="width:225px" %)High humidity|(% style="width:426px" %)Increased humidity inside the battery|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %) |(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)High humidity|(% style="width:49px" %)HHU|(% style="width:166px" %)0x4020 sub 0x00, bit 6|(% style="width:159px" %)0x2007-0x2008, bit 6
112 -|(% style="width:225px" %)High Logic temperature
113 -High board temperature|(% style="width:426px" %)BMS Main devices: at least one of the Logic devices is overheated
114 -BMS Mini devices: BMS Mini device is overheated|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)Hi. Logic temp.|(% style="width:49px" %)HLT|(% style="width:166px" %)0x4020 sub 0x00, bit 8|(% style="width:159px" %)0x2007-0x2008, bit 8
112 +|(% style="width:225px" %)High Logic temperature|(% style="width:426px" %)At least one of the Logic devices is overheated|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %) |(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)Hi. Logic temp.|(% style="width:49px" %)HLT|(% style="width:166px" %)0x4020 sub 0x00, bit 8|(% style="width:159px" %)0x2007-0x2008, bit 8
115 115  |(% style="width:225px" %)High temperature (CH)|(% style="width:426px" %)Temperature is too high for charging|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)High temp. CH|(% style="width:49px" %)HTC|(% style="width:166px" %)0x4021 sub 0x00, bit 1|(% style="width:159px" %)0x200E-0x200F, bit 1
116 116  |(% style="width:225px" %)High temperature (DCH)|(% style="width:426px" %)Temperature is too high for discharging|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)High temp. DCH|(% style="width:49px" %)HTD|(% style="width:166px" %)0x4020 sub 0x00, bit 4|(% style="width:159px" %)0x2007-0x2008, bit 4
117 117  |(% style="width:225px" %)High voltage fault|(% style="width:426px" %)Failure of high voltage measuring circuits|(% style="text-align:center; width:77px" %)**•**|(% style="text-align:center; width:93px" %) |(% style="text-align:center; width:80px" %) |(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)HV fault|(% style="width:49px" %)HVF|(% style="width:166px" %)0x4021 sub 0x00, bit 14|(% style="width:159px" %)0x200E-0x200F, bit 14
... ... @@ -119,8 +119,7 @@
119 119  |(% style="width:225px" %)HYG offline|(% style="width:426px" %)Connection with the HYG forklift is lost|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)HYG offline|(% style="width:49px" %)HYG|(% style="width:166px" %)0x4020 sub 0x00, bit 13|(% style="width:159px" %)0x2007-0x2008, bit 13
120 120  |(% style="width:225px" %)Insulation fault|(% style="width:426px" %)Insulation resistance is too low|(% style="text-align:center; width:77px" %)**•**|(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)Insulation fault|(% style="width:49px" %)INF|(% style="width:166px" %)0x4021 sub 0x00, bit 8|(% style="width:159px" %)0x200E-0x200F, bit 8
121 121  |(% style="width:225px" %)Logic count error|(% style="width:426px" %)The number of BMS Logic devices differs from the required value|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %) |(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)Logic count|(% style="width:49px" %)LOG|(% style="width:166px" %)0x4020 sub 0x00, bit 18|(% style="width:159px" %)0x2007-0x2008, bit 18
122 -|(% style="width:225px" %)Logic offline
123 -Cell monitor offline|(% style="width:426px" %)BMS Main devices: at least one of the Logic devices is offline.
120 +|(% style="width:225px" %)Logic offline (Cell monitor offline)|(% style="width:426px" %)BMS Main devices: at least one of the Logic devices is offline.
124 124  BMS Mini devices: connection with cell monitor is lost.|(% style="text-align:center; width:77px" %)**•**|(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)Logic offline|(% style="width:49px" %)LOF|(% style="width:166px" %)0x4020 sub 0x00, bit 9|(% style="width:159px" %)0x2007-0x2008, bit 9
125 125  |(% style="width:225px" %)Low temperature (CH)|(% style="width:426px" %)Temperature is too low for charging;|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)Low temp. CH|(% style="width:49px" %)LTC|(% style="width:166px" %)0x4021 sub 0x00, bit 0|(% style="width:159px" %)0x200E-0x200F, bit 0
126 126  |(% style="width:225px" %)Low temperature (DCH)|(% style="width:426px" %)Temperature is too low for discharging;|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)Low temp. DCH|(% style="width:49px" %)LTD|(% style="width:166px" %)0x4020 sub 0x00, bit 3|(% style="width:159px" %)0x2007-0x2008, bit 3