... ... @@ -96,7 +96,7 @@
96 96  |(% style="width:225px" %)CH contactor feedback error|(% style="width:426px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="text-align:center; width:77px" %)**•**|(% style="text-align:center; width:93px" %) |(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)CH cont. feed.|(% style="width:49px" %)CCF|(% style="width:166px" %)0x4021 sub 0x00, bit 6|(% style="width:159px" %)0x200E-0x200F, bit 6
97 97  |(% style="width:225px" %)CH/DCH contactor feedback error|(% style="width:426px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="text-align:center; width:77px" %)**•**|(% style="text-align:center; width:93px" %) |(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)C/D cont. feed.|(% style="width:49px" %)CDF|(% style="width:166px" %)0x4021 sub 0x00, bit 10|(% style="width:159px" %)0x200E-0x200F, bit 10
98 98  |(% style="width:225px" %)Combilift offline|(% style="width:426px" %)Connection with the Combilift forklift is lost|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)Combilift offl.|(% style="width:49px" %)COM|(% style="width:166px" %)0x4020 sub 0x00, bit 15|(% style="width:159px" %)0x2007-0x2008, bit 15
99 -|(% style="width:225px" %)Contactor feedback error|(% style="width:426px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %) |(% style="text-align:center; width:66px" %) |(% style="width:111px" %)Cont. feed. er.|(% style="width:49px" %)CFE|(% style="width:166px" %)0x4021 sub 0x00, bit 12|(% style="width:159px" %)0x200E-0x200F, bit 12
99 +|(% style="width:225px" %)Contactor feedback error|(% style="width:426px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="text-align:center; width:77px" %)**•**|(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %) |(% style="text-align:center; width:66px" %) |(% style="width:111px" %)Cont. feed. er.|(% style="width:49px" %)CFE|(% style="width:166px" %)0x4021 sub 0x00, bit 12|(% style="width:159px" %)0x200E-0x200F, bit 12
100 100  |(% style="width:225px" %)Critical error|(% style="width:426px" %)Critical system error, the BMS is damaged|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)Critical error|(% style="width:49px" %)CER|(% style="width:166px" %)0x4020 sub 0x00, bit 10|(% style="width:159px" %)0x2007-0x2008, bit 10
101 101  |(% style="width:225px" %)Crown error|(% style="width:426px" %)Connection with the Crown forklift is lost|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %)Yes|(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)Crown error|(% style="width:49px" %)CRO|(% style="width:166px" %)0x4020 sub 0x00, bit 11|(% style="width:159px" %)0x2007-0x2008, bit 11
102 102  |(% style="width:225px" %)Current limit error|(% style="width:426px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="text-align:center; width:77px" %) |(% style="text-align:center; width:93px" %)Yes|(% style="text-align:center; width:80px" %) |(% style="text-align:center; width:66px" %)Yes|(% style="width:111px" %)Cur. limit error|(% style="width:49px" %)CLE|(% style="width:166px" %)0x4021 sub 0x00, bit 19|(% style="width:159px" %)0x200E-0x200F, bit 19