Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,29 +8,29 @@ 8 8 9 9 Here is the list of available input signals of BMS Main 3. 10 10 11 -(% style="width: 905px" %)12 -|(% colspan="1" rowspan="2" style="width:131px" %)**Name**|(%rowspan="2" style="width:43px" %) |(% colspan="1" rowspan="2" style="width:302px" %)**Description**|(%colspan="1" rowspan="2" style="width:187px" %)Compability|(%colspan="3" rowspan="1" style="width:250px" %)**Set up by**|(%colspan="1"rowspan="2"style="width:250px" %)**Abbreviation**13 -|(% style="width: 92px" %)**Dis. input**|(% style="width:69px" %)**CAN**|(% style="width:63px" %)**Modbus**14 - |(% style="width:131px" %)Battery cover |(% style="width:43px" %) |(% style="width:302px" %) a signal from the battery cover;|(% style="width:187px" %)[[Main3>>doc:Battery management systems.BMS Main3.3\. Configuration.3\.4Protections.WebHome||anchor="HBatterycover"]],15 -[[M ain2.1>>doc:Battery management systems.BMS Main2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycover"]], [[MiniS / Mini>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.4 Protections.WebHome||anchor="HBatterycover"]])|(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)16 -|(% style="width:131px" %)Charger connected |(% style="width:4 3px" %)|(% style="width:302px" %)a signal indicating that charger is connected;|(% style="width:187px" %)Charge controller ([[Main 3>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]], [[Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargingcontrol"]], [[Mini S / Mini>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]) Discharge controller ([[Main 3>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HDischarge"]], [[Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargingcontrol"]], [[Mini S / Mini>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HDischarge"]])|(% style="width:92px" %)•|(% style="width:69px" %)•(if corresponding External equipment is online)|(% style="width:63px" %)|(% style="width:63px" %)17 -|(% style="width:131px" %)Power up/down request |(% style="width:4 3px" %)|(% style="width:302px" %)a request to power down the device;|(% style="width:187px" %)Power down controller|(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)18 -|(% style="width:131px" %)Inhibit charging |(% style="width:4 3px" %)|(% style="width:302px" %)a command to open the charging contactor;|(% style="width:187px" %) |(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)19 -|(% style="width:131px" %)Inhibit discharging |(% style="width:4 3px" %)|(% style="width:302px" %)a command to open the discharging contactor;|(% style="width:187px" %) |(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)20 -|(% style="width:131px" %)CH contactor feedback |(% style="width:4 3px" %)|(% style="width:302px" %)a signal from charging contactor feedback loop;|(% style="width:187px" %)Contactor feedback protection|(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)21 -|(% style="width:131px" %)DCH contactor feedback |(% style="width:4 3px" %)|(% style="width:302px" %)a signal from discharging contactor feedback loop;|(% style="width:187px" %)Contactor feedback protection|(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)22 -|(% style="width:131px" %)Insulation status |(% style="width:4 3px" %)|(% style="width:302px" %)a signal from an insulation monitoring device;|(% style="width:187px" %)Insulation protection|(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)23 -|(% style="width:131px" %)Charge request |(% style="width:4 3px" %)|(% style="width:302px" %)a request to close the charging contactor;|(% style="width:187px" %)Charge controller|(% style="width:92px" %)•|(% style="width:69px" %)•(by request)|(% style="width:63px" %)|(% style="width:63px" %)24 -|(% style="width:131px" %)Discharge request |(% style="width:4 3px" %)|(% style="width:302px" %)a request to close the discharging contactor;|(% style="width:187px" %)Discharge controller|(% style="width:92px" %)•|(% style="width:69px" %)•(by request)|(% style="width:63px" %)|(% style="width:63px" %)25 -|(% style="width:131px" %)PCH contactor feedback |(% style="width:4 3px" %)|(% style="width:302px" %)a signal from precharging contactor feedback loop;|(% style="width:187px" %)Contactor feedback protection|(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)26 -|(% style="width:131px" %)CH/DCH contactor feedback |(% style="width:4 3px" %)|(% style="width:302px" %)a signal from charging/discharging contactor feedback loop;|(% style="width:187px" %)Contactor feedback protection|(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)27 -|(% style="width:131px" %)Main contactor feedback |(% style="width:4 3px" %)|(% style="width:302px" %)a signal from main contactor feedback loop;|(% style="width:187px" %)Contactor feedback protection|(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)28 -|(% style="width:131px" %)Interlock |(% style="width:4 3px" %)|(% style="width:302px" %)a signal from interlock loop;|(% style="width:187px" %)Interlock protection|(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)29 -|(% style="width:131px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:4 3px" %)|(%style="width:302px" %) signals from fuses;|(% style="width:187px" %) |(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)30 -|(% style="width:131px" %)Circuit breaker status |(% style="width:4 3px" %)|(%style="width:302px" %) status of protection disconnector;|(% style="width:187px" %) |(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)31 -|(% style="width:131px" %)Balancing request |(% style="width:4 3px" %)|(% style="width:302px" %)a request to balance the cells;|(% style="width:187px" %)Cell balance controller|(% style="width:92px" %)•|(% style="width:69px" %)•|(%style="width:63px" %)|(% style="width:63px" %)32 -|(% style="width:131px" %)Close Main contactor |(% style="width:4 3px" %)|(% style="width:302px" %)a request to close the main contactor;|(% style="width:187px" %)Main contactor controller|(% style="width:92px" %)•|(%style="width:69px" %)•(by request)|(% style="width:63px" %) |(% style="width:63px" %)33 -|(% style="width:131px" %)Close External 1 |(% style="width:4 3px" %)|(% style="width:302px" %)a request to close the External 1 discrete output (if assigned).|(% style="width:187px" %)External 1 internal state|(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)|(% style="width:63px" %)11 +(% style="width:1039px" %) 12 +|(% style="width:131px" %)**Name**|(% style="width:451px" %)**Description**|(% style="width:249px" %)**Compability**|(% style="width:52px" %)**CAN**|(% style="width:98px" %)**Modbus**|(% style="width:90px" %)**Abbreviation** 13 +|(% style="width:131px" %)Battery cover |(% style="width:451px" %) a signal from the battery cover;|(% style="width:249px" %)[[Main 3>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.4 Protections.WebHome||anchor="HBatterycover"]] 14 +[[Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycover"]] 15 +[[Mini S / Mini>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.4 Protections.WebHome||anchor="HBatterycover"]]|(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 16 +|(% style="width:131px" %)Charger connected |(% style="width:451px" %) a signal indicating that charger is connected;|(% style="width:249px" %)[[Main 3>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]], [[Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargingcontrol"]], [[Mini S / Mini>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]|(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 17 +|(% style="width:131px" %)Power up/down request |(% style="width:451px" %) a request to power down the device;|(% style="width:249px" %)Power down controller|(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 18 +|(% style="width:131px" %)Inhibit charging |(% style="width:451px" %) a command to open the charging contactor;|(% style="width:249px" %) |(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 19 +|(% style="width:131px" %)Inhibit discharging |(% style="width:451px" %) a command to open the discharging contactor;|(% style="width:249px" %) |(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 20 +|(% style="width:131px" %)CH contactor feedback |(% style="width:451px" %) a signal from charging contactor feedback loop;|(% style="width:249px" %)Contactor feedback protection|(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 21 +|(% style="width:131px" %)DCH contactor feedback |(% style="width:451px" %) a signal from discharging contactor feedback loop;|(% style="width:249px" %)Contactor feedback protection|(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 22 +|(% style="width:131px" %)Insulation status |(% style="width:451px" %) a signal from an insulation monitoring device;|(% style="width:249px" %)Insulation protection|(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 23 +|(% style="width:131px" %)Charge request |(% style="width:451px" %) a request to close the charging contactor;|(% style="width:249px" %)Charge controller|(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 24 +|(% style="width:131px" %)Discharge request |(% style="width:451px" %) a request to close the discharging contactor;|(% style="width:249px" %)Discharge controller|(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 25 +|(% style="width:131px" %)PCH contactor feedback |(% style="width:451px" %) a signal from precharging contactor feedback loop;|(% style="width:249px" %)Contactor feedback protection|(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 26 +|(% style="width:131px" %)CH/DCH contactor feedback |(% style="width:451px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:249px" %)Contactor feedback protection|(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 27 +|(% style="width:131px" %)Main contactor feedback |(% style="width:451px" %) a signal from main contactor feedback loop;|(% style="width:249px" %)Contactor feedback protection|(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 28 +|(% style="width:131px" %)Interlock |(% style="width:451px" %) a signal from interlock loop;|(% style="width:249px" %)Interlock protection|(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 29 +|(% style="width:131px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:451px" %) signals from fuses;|(% style="width:249px" %) |(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 30 +|(% style="width:131px" %)Circuit breaker status |(% style="width:451px" %) status of protection disconnector;|(% style="width:249px" %) |(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 31 +|(% style="width:131px" %)Balancing request |(% style="width:451px" %) a request to balance the cells;|(% style="width:249px" %)Cell balance controller|(% style="width:52px" %)•|(% style="width:98px" %) |(% style="width:90px" %) 32 +|(% style="width:131px" %)Close Main contactor |(% style="width:451px" %) a request to close the main contactor;|(% style="width:249px" %)Main contactor controller|(% style="width:52px" %)• (by request)|(% style="width:98px" %) |(% style="width:90px" %) 33 +|(% style="width:131px" %)Close External 1 |(% style="width:451px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:249px" %)External 1 internal state|(% style="width:52px" %) |(% style="width:98px" %) |(% style="width:90px" %) 34 34 35 35 === List of internal states === 36 36