Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,7 +12,7 @@ 12 12 |(% colspan="1" rowspan="2" style="width:131px" %)**Name**|(% rowspan="2" style="width:43px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:302px" %)**Description**|(% colspan="1" rowspan="2" style="width:187px" %)**Used by**|(% colspan="3" rowspan="1" style="width:250px" %)**Set up by** 13 13 |(% style="width:92px" %)**Dis. input**|(% style="width:69px" %)**CAN**|(% style="width:63px" %)**Modbus** 14 14 |(% style="width:131px" %)Battery cover |(% style="width:43px" %) |(% style="width:302px" %) a signal from the battery cover;|(% style="width:187px" %)Battery cover protection ([[Main 3>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.4 Protections.WebHome||anchor="HBatterycover"]], [[Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycover"]], [[Mini S / Mini>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.4 Protections.WebHome||anchor="HBatterycover"]])|(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %) 15 -|(% style="width:131px" %)Charger connected |(% style="width:43px" %) |(% style="width:302px" %) a signal indicating that charger is connected;|(% style="width:187px" %)Charge controller, Discharge controller|(% style="width:92px" %)•|(% style="width:69px" %)• (if corresponding External equipment is online)|(% style="width:63px" %) 15 +|(% style="width:131px" %)Charger connected |(% style="width:43px" %) |(% style="width:302px" %) a signal indicating that charger is connected;|(% style="width:187px" %)Charge controller ([[Main 3>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]], [[Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HChargingcontrol"]], [[Mini S / Mini>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]) Discharge controller ([[Main 3>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HDischarge"]], [[Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HDischargingcontrol"]], [[Mini S / Mini>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HDischarge"]])|(% style="width:92px" %)•|(% style="width:69px" %)• (if corresponding External equipment is online)|(% style="width:63px" %) 16 16 |(% style="width:131px" %)Power up/down request |(% style="width:43px" %) |(% style="width:302px" %) a request to power down the device;|(% style="width:187px" %)Power down controller|(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %) 17 17 |(% style="width:131px" %)Inhibit charging |(% style="width:43px" %) |(% style="width:302px" %) a command to open the charging contactor;|(% style="width:187px" %) |(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %) 18 18 |(% style="width:131px" %)Inhibit discharging |(% style="width:43px" %) |(% style="width:302px" %) a command to open the discharging contactor;|(% style="width:187px" %) |(% style="width:92px" %)•|(% style="width:69px" %) |(% style="width:63px" %)