... ... @@ -11,7 +11,7 @@
11 11  (% style="width:1274px" %)
12 12  |(% style="width:131px" %)**Name**|(% style="width:451px" %)**Description**|(% colspan="3" rowspan="1" style="width:414px" %)**Compability**|(% style="width:83px" %)**CANopen SDO**|(% style="width:113px" %)**Modbus**|(% style="width:86px" %)**Abbreviation**
13 13  |(% style="width:131px" %) |(% style="width:451px" %) |(% style="width:134px" %)**Mini S / Mini**|(% style="width:141px" %)**Main 2.1**|(% style="width:142px" %)**Main 3**|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)
14 -|(% style="width:131px" %)Battery cover |(% style="width:451px" %) a signal from the battery cover;|(% style="width:134px" %)[[Battery cover protection>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.4 Protections.WebHome||anchor="HBatterycover"]]|(% style="width:141px" %)[[Battery cover protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycover"]]|(% style="width:142px" %)[[Battery cover protection>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.4 Protections.WebHome||anchor="HBatterycover"]]|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)
14 +|(% style="width:131px" %)Battery cover |(% style="width:451px" %) a signal from the battery cover;|(% style="width:134px" %)[[Battery cover protection>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.4 Protections.WebHome||anchor="HBatterycover"]]|(% style="width:141px" %)[[Battery cover protection>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycoverprotection"]]|(% style="width:142px" %)[[Battery cover protection>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.4 Protections.WebHome||anchor="HBatterycover"]]|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)
15 15  |(% style="width:131px" %)Charger connected |(% style="width:451px" %) a signal indicating that charger is connected;|(% style="width:134px" %)(((
16 16  [[Charge controller>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HCharge"]]
17 17  
... ... @@ -25,7 +25,7 @@
25 25  
26 26  [[Discharge controller>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HDischarge"]]
27 27  )))|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)
28 -|(% style="width:131px" %)Power up/down request |(% style="width:451px" %) a request to power down the device;|(% style="width:134px" %)Power down controller|(% style="width:141px" %)Power down controller|(% style="width:142px" %)Power down controller|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)
28 +|(% style="width:131px" %)Power up/down request |(% style="width:451px" %) a request to power down the device;|(% style="width:134px" %)[[Power down controller>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.3 Control.WebHome||anchor="HPowerdown"]]|(% style="width:141px" %)[[Power down controller>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.5 Battery control.WebHome||anchor="HPowerdowncontrol"]]|(% style="width:142px" %)[[Power down controller>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.3 Control.WebHome||anchor="HPowerdown"]]|(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)
29 29  |(% style="width:131px" %)Inhibit charging |(% style="width:451px" %) a command to open the charging contactor;|(% style="width:134px" %) |(% style="width:141px" %) |(% style="width:142px" %) |(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)
30 30  |(% style="width:131px" %)Inhibit discharging |(% style="width:451px" %) a command to open the discharging contactor;|(% style="width:134px" %) |(% style="width:141px" %) |(% style="width:142px" %) |(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)
31 31  |(% style="width:131px" %)CH contactor feedback |(% style="width:451px" %) a signal from charging contactor feedback loop;|(% style="width:134px" %)Contactor feedback protection|(% style="width:141px" %) |(% style="width:142px" %) |(% style="width:83px" %) |(% style="width:113px" %) |(% style="width:86px" %)