Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -17,8 +17,8 @@ 17 17 |(% style="width:197px" %)CH/DCH contactor feedback|(% style="width:409px" %)Signal from the charging/discharging contactor feedback loop|(% style="width:96px" %)Yes*|(% style="width:83px" %)Yes|(% style="width:71px" %)Yes|(% style="width:125px" %)C/D cont. feed.|(% style="width:45px" %)CDF|(% style="width:132px" %)0x5100, sub 0x0D|(% style="width:81px" %)0x510C|(% style="width:159px" %)0x4000 sub 0x00, bit 12|(% style="width:123px" %)0x2000, bit 12 18 18 |(% style="width:197px" %)Charge request|(% style="width:409px" %)Request to close the charging contactor|(% style="width:96px" %)Yes|(% style="width:83px" %)Yes|(% style="width:71px" %)Yes|(% style="width:125px" %)Charge request|(% style="width:45px" %)CRE|(% style="width:132px" %)0x5100, sub 0x09|(% style="width:81px" %)0x5108|(% style="width:159px" %)0x4000 sub 0x00, bit 8|(% style="width:123px" %)0x2000, bit 8 19 19 |(% style="width:197px" %)Charger connected|(% style="width:409px" %)Signal indicating that the charger is connected|(% style="width:96px" %)Yes|(% style="width:83px" %)Yes|(% style="width:71px" %)Yes|(% style="width:125px" %)Charger connect.|(% style="width:45px" %)CON|(% style="width:132px" %)0x5100, sub 0x02|(% style="width:81px" %)0x5101|(% style="width:159px" %)0x4000 sub 0x00, bit 1|(% style="width:123px" %)0x2000, bit 1 20 -|(% style="width:197px" %)Circuit breaker status|(% style="width:409px" %)Status of protective disconnector|(% style="width:96px" %)Yes|(% style="width:83px" %)Yes|(% style="width:71px" %)Yes|(% style="width:125px" %)Circuit breaker|(% style="width:45px" %)CBS|(% style="width:132px" %)0x5100, sub 0x13|(% style="width:81px" %)0x5112|(% style="width:159px" %)0x400 0sub 0x00, bit 2|(% style="width:123px" %)0x20F4, bit 221 -|(% style="width:197px" %)Close External 1|(% style="width:409px" %)Request to set the External 1 signal|(% style="width:96px" %)Yes|(% style="width:83px" %)Yes|(% style="width:71px" %)Yes|(% style="width:125px" %)Close Ext.1|(% style="width:45px" %)CE1|(% style="width:132px" %)0x5100, sub 0x16|(% style="width:81px" %)0x5115|(% style="width:159px" %)0x400 0sub 0x00, bit 5|(% style="width:123px" %)0x20F4, bit 520 +|(% style="width:197px" %)Circuit breaker status|(% style="width:409px" %)Status of protective disconnector|(% style="width:96px" %)Yes|(% style="width:83px" %)Yes|(% style="width:71px" %)Yes|(% style="width:125px" %)Circuit breaker|(% style="width:45px" %)CBS|(% style="width:132px" %)0x5100, sub 0x13|(% style="width:81px" %)0x5112|(% style="width:159px" %)0x4001 sub 0x00, bit 2|(% style="width:123px" %)0x20F4, bit 2 21 +|(% style="width:197px" %)Close External 1|(% style="width:409px" %)Request to set the External 1 signal|(% style="width:96px" %)Yes|(% style="width:83px" %)Yes|(% style="width:71px" %)Yes|(% style="width:125px" %)Close Ext.1|(% style="width:45px" %)CE1|(% style="width:132px" %)0x5100, sub 0x16|(% style="width:81px" %)0x5115|(% style="width:159px" %)0x4001 sub 0x00, bit 5|(% style="width:123px" %)0x20F4, bit 5 22 22 |(% style="width:197px" %)Close Main contactor|(% style="width:409px" %)Request to close the main contactor|(% style="width:96px" %)Yes|(% style="width:83px" %)Yes|(% style="width:71px" %)Yes|(% style="width:125px" %)Close Main cont.|(% style="width:45px" %)CMC|(% style="width:132px" %)0x5100, sub 0x15|(% style="width:81px" %)0x5114|(% style="width:159px" %)0x4030 sub 0x00, bit 4|(% style="width:123px" %)0x20F4, bit 4 23 23 |(% style="width:197px" %)DCH contactor feedback|(% style="width:409px" %)Signal from the discharging contactor feedback loop|(% style="width:96px" %)Yes*|(% style="width:83px" %)Yes|(% style="width:71px" %)Yes|(% style="width:125px" %)DCH cont. feed.|(% style="width:45px" %)DCF|(% style="width:132px" %)0x5100, sub 0x07|(% style="width:81px" %)0x5106|(% style="width:159px" %)0x4000 sub 0x00, bit 6|(% style="width:123px" %)0x2000, bit 6 24 24 |(% style="width:197px" %)Discharge request|(% style="width:409px" %)Request to close the discharging contactor|(% style="width:96px" %)Yes|(% style="width:83px" %)Yes|(% style="width:71px" %)Yes|(% style="width:125px" %)Discharge req.|(% style="width:45px" %)DRE|(% style="width:132px" %)0x5100, sub 0x0B|(% style="width:81px" %)0x510A|(% style="width:159px" %)0x4000 sub 0x00, bit 10|(% style="width:123px" %)0x2000, bit 10