Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -115,15 +115,15 @@ 115 115 |(% style="width:225px" %)Logic count error|(% style="width:426px" %)The number of BMS Logic devices differs from the required value|(% style="width:77px" %) |(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Logic count|(% style="width:40px" %)LOG|(% style="width:190px" %)0x4020 sub 0x00, bit 18|(% style="width:190px" %)0x2007-0x2008, bit 18 116 116 |(% style="width:225px" %)Logic offline (Cell monitor offline)|(% style="width:426px" %)BMS Main devices: at least one of the Logic devices is offline. 117 117 BMS Mini devices: connection with cell monitor is lost.|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Logic offline|(% style="width:40px" %)LOF|(% style="width:190px" %)0x4020 sub 0x00, bit 9|(% style="width:190px" %)0x2007-0x2008, bit 9 118 -|(% style="width:225px" %)Low temperature (CH)|(% style="width:426px" %)Temperature is too low for charging;|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Low temp. CH|(% style="width:40px" %)LTC|(% style="width:190px" %)0x20 0E-0x200F,118 +|(% style="width:225px" %)Low temperature (CH)|(% style="width:426px" %)Temperature is too low for charging;|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Low temp. CH|(% style="width:40px" %)LTC|(% style="width:190px" %)0x4021 sub 0x00, bit 0|(% style="width:190px" %)0x200E-0x200F, bit 0 119 119 |(% style="width:225px" %)Low temperature (DCH)|(% style="width:426px" %)Temperature is too low for discharging;|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Low temp. DCH|(% style="width:40px" %)LTD|(% style="width:190px" %)0x4020 sub 0x00, bit 3|(% style="width:190px" %)0x2007-0x2008, bit 3 120 -|(% style="width:225px" %)Main contactor feedback error|(% style="width:426px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Main cont. feed.|(% style="width:40px" %)MCF|(% style="width:190px" %)0x20 0E-0x200F,121 -|(% style="width:225px" %)Mount error|(% style="width:426px" %)SD card cannot be mounted|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Mount error|(% style="width:40px" %)MNT|(% style="width:190px" %)0x20 0E-0x200F,120 +|(% style="width:225px" %)Main contactor feedback error|(% style="width:426px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Main cont. feed.|(% style="width:40px" %)MCF|(% style="width:190px" %)0x4021 sub 0x00, bit 11|(% style="width:190px" %)0x200E-0x200F, bit 11 121 +|(% style="width:225px" %)Mount error|(% style="width:426px" %)SD card cannot be mounted|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Mount error|(% style="width:40px" %)MNT|(% style="width:190px" %)0x4021 sub 0x00, bit 2|(% style="width:190px" %)0x200E-0x200F, bit 2 122 122 |(% style="width:225px" %)Need acknowledge|(% style="width:426px" %)There is an unacknowledged error in error journal|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Need ACK|(% style="width:40px" %)ACK|(% style="width:190px" %)0x4020 sub 0x00, bit 14|(% style="width:190px" %)0x2007-0x2008, bit 14 123 123 |(% style="width:225px" %)No temperature sensors|(% style="width:426px" %)The device has no temperature sensors connected|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)No temp. sens.|(% style="width:40px" %)NTS|(% style="width:190px" %)0x4020 sub 0x00, bit 27|(% style="width:190px" %)0x2007-0x2008, bit 27 124 124 |(% style="width:225px" %)Overcurrent|(% style="width:426px" %)The battery current is too high|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Overcurrent|(% style="width:40px" %)OC|(% style="width:190px" %)0x4020 sub 0x00, bit 0|(% style="width:190px" %)0x2007-0x2008, bit 0 125 125 |(% style="width:225px" %)Overvoltage|(% style="width:426px" %)Voltage of any cell is too high|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Overvoltage|(% style="width:40px" %)OV|(% style="width:190px" %)0x4020 sub 0x00, bit 2|(% style="width:190px" %)0x2007-0x2008, bit 2 126 -|(% style="width:225px" %)PCH contactor feedback error|(% style="width:426px" %)The control signal for the precharging contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)PCH cont. feed.|(% style="width:40px" %)PCF|(% style="width:190px" %)0x20 0E-0x200F,126 +|(% style="width:225px" %)PCH contactor feedback error|(% style="width:426px" %)The control signal for the precharging contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)PCH cont. feed.|(% style="width:40px" %)PCF|(% style="width:190px" %)0x4021 sub 0x00, bit 9|(% style="width:190px" %)0x200E-0x200F, bit 9 127 127 |(% style="width:225px" %)Power fault|(% style="width:426px" %)External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %) |(% style="width:66px" %)Yes|(% style="width:137px" %)Power fault|(% style="width:40px" %)PF|(% style="width:190px" %)0x200E-0x200F, bit 18|(% style="width:190px" %)0x200E-0x200F, bit 18 128 128 |(% style="width:225px" %)Power switch error|(% style="width:426px" %)Short circuit in contactor coil control circuit or power switch overheating|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %) |(% style="width:66px" %)Yes|(% style="width:137px" %)PSW error|(% style="width:40px" %)PSE|(% style="width:190px" %)0x200E-0x200F, bit 15|(% style="width:190px" %)0x200E-0x200F, bit 15 129 129 |(% style="width:225px" %)Precharge error|(% style="width:426px" %)Capacitive load pre-charge process did not end during the estimated time|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Precharge error|(% style="width:40px" %)PE|(% style="width:190px" %)0x200E-0x200F, bit 17|(% style="width:190px" %)0x200E-0x200F, bit 17