Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -106,12 +106,12 @@ 106 106 |(% style="width:225px" %)High contactor temperature|(% style="width:426px" %)Temperature of a contactor is too high|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Hi. cont. temp.|(% style="width:40px" %)HCT|(% style="width:190px" %)0x4020 sub 0x00, bit 17|(% style="width:190px" %)0x2007-0x2008, bit 17 107 107 |(% style="width:225px" %)High humidity|(% style="width:426px" %)Increased humidity inside the battery|(% style="width:77px" %) |(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)High humidity|(% style="width:40px" %)HHU|(% style="width:190px" %)0x4020 sub 0x00, bit 6|(% style="width:190px" %)0x2007-0x2008, bit 6 108 108 |(% style="width:225px" %)High Logic temperature|(% style="width:426px" %)At least one of the Logic devices is overheated|(% style="width:77px" %) |(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Hi. Logic temp.|(% style="width:40px" %)HLT|(% style="width:190px" %)0x4020 sub 0x00, bit 8|(% style="width:190px" %)0x2007-0x2008, bit 8 109 -|(% style="width:225px" %)High temperature (CH)|(% style="width:426px" %)Temperature is too high for charging|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)High temp. CH|(% style="width:40px" %)HTC|(% style="width:190px" %)0x20 0E-0x200F,109 +|(% style="width:225px" %)High temperature (CH)|(% style="width:426px" %)Temperature is too high for charging|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)High temp. CH|(% style="width:40px" %)HTC|(% style="width:190px" %)0x4021 sub 0x00, bit 1|(% style="width:190px" %)0x200E-0x200F, bit 1 110 110 |(% style="width:225px" %)High temperature (DCH)|(% style="width:426px" %)Temperature is too high for discharging|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)High temp. DCH|(% style="width:40px" %)HTD|(% style="width:190px" %)0x4020 sub 0x00, bit 4|(% style="width:190px" %)0x2007-0x2008, bit 4 111 -|(% style="width:225px" %)High voltage fault|(% style="width:426px" %)Failure of high voltage measuring circuits|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %) |(% style="width:66px" %)Yes|(% style="width:137px" %)HV fault|(% style="width:40px" %)HVF|(% style="width:190px" %)0x20 0E-0x200F,112 -|(% style="width:225px" %)HVIL error|(% style="width:426px" %)Breakage of high-voltage interlock current loop|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %) |(% style="width:66px" %)Yes|(% style="width:137px" %)HVIL error|(% style="width:40px" %)HE|(% style="width:190px" %)0x20 0E-0x200F,111 +|(% style="width:225px" %)High voltage fault|(% style="width:426px" %)Failure of high voltage measuring circuits|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %) |(% style="width:66px" %)Yes|(% style="width:137px" %)HV fault|(% style="width:40px" %)HVF|(% style="width:190px" %)0x4021 sub 0x00, bit 14|(% style="width:190px" %)0x200E-0x200F, bit 14 112 +|(% style="width:225px" %)HVIL error|(% style="width:426px" %)Breakage of high-voltage interlock current loop|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %) |(% style="width:66px" %)Yes|(% style="width:137px" %)HVIL error|(% style="width:40px" %)HE|(% style="width:190px" %)0x4021 sub 0x00, bit 16|(% style="width:190px" %)0x200E-0x200F, bit 16 113 113 |(% style="width:225px" %)HYG offline|(% style="width:426px" %)Connection with the HYG forklift is lost|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)HYG offline|(% style="width:40px" %)HYG|(% style="width:190px" %)0x4020 sub 0x00, bit 13|(% style="width:190px" %)0x2007-0x2008, bit 13 114 -|(% style="width:225px" %)Insulation fault|(% style="width:426px" %)Insulation resistance is too low|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Insulation fault|(% style="width:40px" %)INF|(% style="width:190px" %)0x20 0E-0x200F,114 +|(% style="width:225px" %)Insulation fault|(% style="width:426px" %)Insulation resistance is too low|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Insulation fault|(% style="width:40px" %)INF|(% style="width:190px" %)0x4021 sub 0x00, bit 8|(% style="width:190px" %)0x200E-0x200F, bit 8 115 115 |(% style="width:225px" %)Logic count error|(% style="width:426px" %)The number of BMS Logic devices differs from the required value|(% style="width:77px" %) |(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Logic count|(% style="width:40px" %)LOG|(% style="width:190px" %)0x4020 sub 0x00, bit 18|(% style="width:190px" %)0x2007-0x2008, bit 18 116 116 |(% style="width:225px" %)Logic offline (Cell monitor offline)|(% style="width:426px" %)BMS Main devices: at least one of the Logic devices is offline. 117 117 BMS Mini devices: connection with cell monitor is lost.|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Logic offline|(% style="width:40px" %)LOF|(% style="width:190px" %)0x4020 sub 0x00, bit 9|(% style="width:190px" %)0x2007-0x2008, bit 9