Last modified by Admin on 2025/03/03 15:20

From version 29.36
edited by Admin
on 2025/02/06 17:12
Change comment: There is no comment for this version
To version 29.34
edited by Admin
on 2025/02/06 17:12
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -90,11 +90,11 @@
90 90  |(% style="width:225px" %)ADC error|(% style="width:426px" %)Error of the ADC that measures the battery current|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)ADC error|(% style="width:40px" %)ADC|(% style="width:190px" %)0x4020 sub 0x00, bit 19|(% style="width:190px" %)0x2007-0x2008, bit 19
91 91  |(% style="width:225px" %)Battery cover error|(% style="width:426px" %)Battery cover is open|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Battery cover|(% style="width:40px" %)BCE|(% style="width:190px" %)0x4020 sub 0x00, bit 5|(% style="width:190px" %)0x2007-0x2008, bit 5
92 92  |(% style="width:225px" %)Cell count error|(% style="width:426px" %)Number of cells does not match the specified value|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Cell count|(% style="width:40px" %)CEL|(% style="width:190px" %)0x4020 sub 0x00, bit 12|(% style="width:190px" %)0x2007-0x2008, bit 12
93 -|(% style="width:225px" %)CH contactor cycles error|(% style="width:426px" %)Switching frequency of the charging contactor is too high|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)CH cont. cycle|(% style="width:40px" %)CCC|(% style="width:190px" %)0x4020 sub 0x00, bit 21|(% style="width:190px" %)0x2007-0x2008, bit 21
94 -|(% style="width:225px" %)CH contactor feedback error|(% style="width:426px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)CH cont. feed.|(% style="width:40px" %)CCF|(% style="width:190px" %)0x4021 sub 0x00, bit 6|(% style="width:190px" %)0x200E-0x200F, bit 6
95 -|(% style="width:225px" %)CH/DCH contactor feedback error|(% style="width:426px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)C/D cont. feed.|(% style="width:40px" %)CDF|(% style="width:190px" %)0x4021 sub 0x00, bit 10|(% style="width:190px" %)0x200E-0x200F, bit 10
93 +|(% style="width:225px" %)CH contactor cycles error|(% style="width:426px" %)Switching frequency of the charging contactor is too high|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)CH cont. cycle|(% style="width:40px" %)CCC|(% style="width:190px" %)0x2007-0x2008, bit 21|(% style="width:190px" %)0x2007-0x2008, bit 21
94 +|(% style="width:225px" %)CH contactor feedback error|(% style="width:426px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)CH cont. feed.|(% style="width:40px" %)CCF|(% style="width:190px" %)0x200E-0x200F, bit 6|(% style="width:190px" %)0x200E-0x200F, bit 6
95 +|(% style="width:225px" %)CH/DCH contactor feedback error|(% style="width:426px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)C/D cont. feed.|(% style="width:40px" %)CDF|(% style="width:190px" %)0x200E-0x200F, bit 10|(% style="width:190px" %)0x200E-0x200F, bit 10
96 96  |(% style="width:225px" %)Combilift offline|(% style="width:426px" %)Connection with the Combilift forklift is lost|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Combilift offl.|(% style="width:40px" %)COM|(% style="width:190px" %)0x4020 sub 0x00, bit 15|(% style="width:190px" %)0x2007-0x2008, bit 15
97 -|(% style="width:225px" %)Contactor feedback error|(% style="width:426px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %) |(% style="width:66px" %) |(% style="width:137px" %)Cont. feed. er.|(% style="width:40px" %)CFE|(% style="width:190px" %)0x4021 sub 0x00, bit 12|(% style="width:190px" %)0x200E-0x200F, bit 12
97 +|(% style="width:225px" %)Contactor feedback error|(% style="width:426px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %) |(% style="width:66px" %) |(% style="width:137px" %)Cont. feed. er.|(% style="width:40px" %)CFE|(% style="width:190px" %)0x200E-0x200F, bit 12|(% style="width:190px" %)0x200E-0x200F, bit 12
98 98  |(% style="width:225px" %)Critical error|(% style="width:426px" %)Critical system error, the BMS is damaged|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Critical error|(% style="width:40px" %)CER|(% style="width:190px" %)0x4020 sub 0x00, bit 10|(% style="width:190px" %)0x2007-0x2008, bit 10
99 99  |(% style="width:225px" %)Crown error|(% style="width:426px" %)Connection with the Crown forklift is lost|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Crown error|(% style="width:40px" %)CRO|(% style="width:190px" %)0x4020 sub 0x00, bit 11|(% style="width:190px" %)0x2007-0x2008, bit 11
100 100  |(% style="width:225px" %)Current limit error|(% style="width:426px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %) |(% style="width:66px" %)Yes|(% style="width:137px" %)Cur. limit error|(% style="width:40px" %)CLE|(% style="width:190px" %)0x200E-0x200F, bit 19|(% style="width:190px" %)0x200E-0x200F, bit 19