Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -90,11 +90,11 @@ 90 90 |(% style="width:225px" %)ADC error|(% style="width:426px" %)Error of the ADC that measures the battery current|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)ADC error|(% style="width:40px" %)ADC|(% style="width:190px" %)0x4020 sub 0x00, bit 19|(% style="width:190px" %)0x2007-0x2008, bit 19 91 91 |(% style="width:225px" %)Battery cover error|(% style="width:426px" %)Battery cover is open|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Battery cover|(% style="width:40px" %)BCE|(% style="width:190px" %)0x4020 sub 0x00, bit 5|(% style="width:190px" %)0x2007-0x2008, bit 5 92 92 |(% style="width:225px" %)Cell count error|(% style="width:426px" %)Number of cells does not match the specified value|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Cell count|(% style="width:40px" %)CEL|(% style="width:190px" %)0x4020 sub 0x00, bit 12|(% style="width:190px" %)0x2007-0x2008, bit 12 93 -|(% style="width:225px" %)CH contactor cycles error|(% style="width:426px" %)Switching frequency of the charging contactor is too high|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)CH cont. cycle|(% style="width:40px" %)CCC|(% style="width:190px" %)0x 4020sub0x00, bit 21|(% style="width:190px" %)0x2007-0x2008, bit 2194 -|(% style="width:225px" %)CH contactor feedback error|(% style="width:426px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)CH cont. feed.|(% style="width:40px" %)CCF|(% style="width:190px" %)0x 4021 sub0x00, bit 6|(% style="width:190px" %)0x200E-0x200F, bit 695 -|(% style="width:225px" %)CH/DCH contactor feedback error|(% style="width:426px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)C/D cont. feed.|(% style="width:40px" %)CDF|(% style="width:190px" %)0x 4021 sub0x00, bit 10|(% style="width:190px" %)0x200E-0x200F, bit 1093 +|(% style="width:225px" %)CH contactor cycles error|(% style="width:426px" %)Switching frequency of the charging contactor is too high|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)CH cont. cycle|(% style="width:40px" %)CCC|(% style="width:190px" %)0x2007-0x2008, bit 21|(% style="width:190px" %)0x2007-0x2008, bit 21 94 +|(% style="width:225px" %)CH contactor feedback error|(% style="width:426px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)CH cont. feed.|(% style="width:40px" %)CCF|(% style="width:190px" %)0x200E-0x200F, bit 6|(% style="width:190px" %)0x200E-0x200F, bit 6 95 +|(% style="width:225px" %)CH/DCH contactor feedback error|(% style="width:426px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)C/D cont. feed.|(% style="width:40px" %)CDF|(% style="width:190px" %)0x200E-0x200F, bit 10|(% style="width:190px" %)0x200E-0x200F, bit 10 96 96 |(% style="width:225px" %)Combilift offline|(% style="width:426px" %)Connection with the Combilift forklift is lost|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Combilift offl.|(% style="width:40px" %)COM|(% style="width:190px" %)0x4020 sub 0x00, bit 15|(% style="width:190px" %)0x2007-0x2008, bit 15 97 -|(% style="width:225px" %)Contactor feedback error|(% style="width:426px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %) |(% style="width:66px" %) |(% style="width:137px" %)Cont. feed. er.|(% style="width:40px" %)CFE|(% style="width:190px" %)0x 4021 sub0x00, bit 12|(% style="width:190px" %)0x200E-0x200F, bit 1297 +|(% style="width:225px" %)Contactor feedback error|(% style="width:426px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %) |(% style="width:66px" %) |(% style="width:137px" %)Cont. feed. er.|(% style="width:40px" %)CFE|(% style="width:190px" %)0x200E-0x200F, bit 12|(% style="width:190px" %)0x200E-0x200F, bit 12 98 98 |(% style="width:225px" %)Critical error|(% style="width:426px" %)Critical system error, the BMS is damaged|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Critical error|(% style="width:40px" %)CER|(% style="width:190px" %)0x4020 sub 0x00, bit 10|(% style="width:190px" %)0x2007-0x2008, bit 10 99 99 |(% style="width:225px" %)Crown error|(% style="width:426px" %)Connection with the Crown forklift is lost|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Crown error|(% style="width:40px" %)CRO|(% style="width:190px" %)0x4020 sub 0x00, bit 11|(% style="width:190px" %)0x2007-0x2008, bit 11 100 100 |(% style="width:225px" %)Current limit error|(% style="width:426px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %) |(% style="width:66px" %)Yes|(% style="width:137px" %)Cur. limit error|(% style="width:40px" %)CLE|(% style="width:190px" %)0x200E-0x200F, bit 19|(% style="width:190px" %)0x200E-0x200F, bit 19 ... ... @@ -135,8 +135,8 @@ 135 135 |(% style="width:225px" %)Stuck contactor|(% style="width:426px" %)Some contactor got stuck|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Stuck contactor|(% style="width:40px" %)STC|(% style="width:190px" %)0x200E-0x200F, bit 5|(% style="width:190px" %)0x200E-0x200F, bit 5 136 136 |(% style="width:225px" %)Temperature sensor is shorted|(% style="width:426px" %)Some temperature sensors are shorted|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Shorted temp.|(% style="width:40px" %)TSS|(% style="width:190px" %)0x4020 sub 0x00, bit 28|(% style="width:190px" %)0x2007-0x2008, bit 28 137 137 |(% style="width:225px" %)Unallowable charging|(% style="width:426px" %)Charging the battery through the discharging contactor|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Unallowable CH|(% style="width:40px" %)UCH|(% style="width:190px" %)0x200E-0x200F, bit 4|(% style="width:190px" %)0x200E-0x200F, bit 4 138 -|(% style="width:225px" %)Undervoltage|(% style="width:426px" %)Voltage of any cell is too low|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Undervoltage|(% style="width:40px" %)UV|(% style="width:190px" %)0x 4020sub0x00, bit 1|(% style="width:190px" %)0x2007-0x2008, bit 1139 -|(% style="width:225px" %)Water|(% style="width:426px" %)There is water in the battery enclosure|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Water|(% style="width:40px" %)WHU|(% style="width:190px" %)0x 4020sub0x00, bit 7|(% style="width:190px" %)0x2007-0x2008, bit 7140 -|(% style="width:225px" %)WDT reset|(% style="width:426px" %)Watchdog timer reset the device|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)WDT reset|(% style="width:40px" %)WDT|(% style="width:190px" %)0x 4020sub0x00, bit 26|(% style="width:190px" %)0x2007-0x2008, bit 26138 +|(% style="width:225px" %)Undervoltage|(% style="width:426px" %)Voltage of any cell is too low|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Undervoltage|(% style="width:40px" %)UV|(% style="width:190px" %)0x2007-0x2008, bit 1|(% style="width:190px" %)0x2007-0x2008, bit 1 139 +|(% style="width:225px" %)Water|(% style="width:426px" %)There is water in the battery enclosure|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Water|(% style="width:40px" %)WHU|(% style="width:190px" %)0x2007-0x2008, bit 7|(% style="width:190px" %)0x2007-0x2008, bit 7 140 +|(% style="width:225px" %)WDT reset|(% style="width:426px" %)Watchdog timer reset the device|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)WDT reset|(% style="width:40px" %)WDT|(% style="width:190px" %)0x2007-0x2008, bit 26|(% style="width:190px" %)0x2007-0x2008, bit 26 141 141 142 142 ~* The signal can be assigned to discrete outputs and relays.