95 95  |(% style="width:225px" %)CH/DCH contactor feedback error|(% style="width:426px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)C/D cont. feed.|(% style="width:40px" %)CDF|(% style="width:190px" %)0x200E-0x200F, bit 10|(% style="width:190px" %)0x200E-0x200F, bit 10
96 96  |(% style="width:225px" %)Combilift offline|(% style="width:426px" %)Connection with the Combilift forklift is lost|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Combilift offl.|(% style="width:40px" %)COM|(% style="width:190px" %)0x4020 sub 0x00, bit 15|(% style="width:190px" %)0x2007-0x2008, bit 15
97 97  |(% style="width:225px" %)Contactor feedback error|(% style="width:426px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %) |(% style="width:66px" %) |(% style="width:137px" %)Cont. feed. er.|(% style="width:40px" %)CFE|(% style="width:190px" %)0x200E-0x200F, bit 12|(% style="width:190px" %)0x200E-0x200F, bit 12
98 -|(% style="width:225px" %)Critical error|(% style="width:426px" %)Critical system error, the BMS is damaged|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Critical error|(% style="width:40px" %)CER|(% style="width:190px" %)0x2007-0x2008, bit 10|(% style="width:190px" %)0x2007-0x2008, bit 10
99 -|(% style="width:225px" %)Crown error|(% style="width:426px" %)Connection with the Crown forklift is lost|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Crown error|(% style="width:40px" %)CRO|(% style="width:190px" %)0x2007-0x2008, bit 11|(% style="width:190px" %)0x2007-0x2008, bit 11
98 +|(% style="width:225px" %)Critical error|(% style="width:426px" %)Critical system error, the BMS is damaged|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Critical error|(% style="width:40px" %)CER|(% style="width:190px" %)0x4020 sub 0x00, bit 10|(% style="width:190px" %)0x2007-0x2008, bit 10
99 +|(% style="width:225px" %)Crown error|(% style="width:426px" %)Connection with the Crown forklift is lost|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Crown error|(% style="width:40px" %)CRO|(% style="width:190px" %)0x4020 sub 0x00, bit 11|(% style="width:190px" %)0x2007-0x2008, bit 11
100 100  |(% style="width:225px" %)Current limit error|(% style="width:426px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %) |(% style="width:66px" %)Yes|(% style="width:137px" %)Cur. limit error|(% style="width:40px" %)CLE|(% style="width:190px" %)0x200E-0x200F, bit 19|(% style="width:190px" %)0x200E-0x200F, bit 19
101 -|(% style="width:225px" %)Current sensor error|(% style="width:426px" %)Error in the current sensor circuit|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Current sensor|(% style="width:40px" %)CSE|(% style="width:190px" %)0x2007-0x2008, bit 20|(% style="width:190px" %)0x2007-0x2008, bit 20
101 +|(% style="width:225px" %)Current sensor error|(% style="width:426px" %)Error in the current sensor circuit|(% style="width:77px" %)Yes|(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)Current sensor|(% style="width:40px" %)CSE|(% style="width:190px" %)0x4020 sub 0x00, bit 20|(% style="width:190px" %)0x2007-0x2008, bit 20
102 102  |(% style="width:225px" %)DCH contactor cycles error|(% style="width:426px" %)Switching frequency of the discharging contactor is too high|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)DCH cont. cycle|(% style="width:40px" %)DCC|(% style="width:190px" %)0x2007-0x2008, bit 22|(% style="width:190px" %)0x2007-0x2008, bit 22
103 103  |(% style="width:225px" %)DCH contactor feedback error|(% style="width:426px" %)The control signal for the discharging contactor and the contactor feedback differ|(% style="width:77px" %)Yes|(% style="width:93px" %) |(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)DCH cont. feed.|(% style="width:40px" %)DCF|(% style="width:190px" %)0x200E-0x200F, bit 7|(% style="width:190px" %)0x200E-0x200F, bit 7
104 104  |(% style="width:225px" %)FS error|(% style="width:426px" %)SD card read/write error|(% style="width:77px" %) |(% style="width:93px" %)Yes|(% style="width:80px" %)Yes|(% style="width:66px" %)Yes|(% style="width:137px" %)FS error|(% style="width:40px" %)FSE|(% style="width:190px" %)0x200E-0x200F, bit 3|(% style="width:190px" %)0x200E-0x200F, bit 3