Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -136,8 +136,8 @@ 136 136 |(% style="width:171px" %)Stuck contactor|(% style="width:324px" %)Some contactor got stuck|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Stuck contactor|(% style="width:54px" %)STC|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 5 137 137 |(% style="width:171px" %)Temperature sensor is shorted|(% style="width:324px" %)Some temperature sensors are shorted|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shorted temp.|(% style="width:54px" %)TSS|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 28 138 138 |(% style="width:171px" %)Unallowable charging|(% style="width:324px" %)Charging the battery through the discharging contactor|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Unallowable CH|(% style="width:54px" %)UCH|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 4 139 -|(% style="width:171px" %)Undervoltage|(% style="width:324px" %)Voltage of any cell is too low|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Undervoltage|(% style="width:54px" %)UV|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 1 140 -|(% style="width:171px" %)Water|(% style="width:324px" %)There is water in the battery enclosure|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Water|(% style="width:54px" %)WHU|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 7 141 -|(% style="width:171px" %)WDT reset|(% style="width:324px" %)Watchdog timer reset the device|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)WDT reset|(% style="width:54px" %)WDT|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 26 139 +|(% style="width:171px" %)Undervoltage|(% style="width:324px" %)Voltage of any cell is too low|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Undervoltage|(% style="width:54px" %)UV|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 1. Off = 0, On = 1. 140 +|(% style="width:171px" %)Water|(% style="width:324px" %)There is water in the battery enclosure|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Water|(% style="width:54px" %)WHU|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 7. Off = 0, On = 1. 141 +|(% style="width:171px" %)WDT reset|(% style="width:324px" %)Watchdog timer reset the device|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)WDT reset|(% style="width:54px" %)WDT|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 26. Off = 0, On = 1. 142 142 143 143 ~* The signal can be assigned to discrete outputs and relays.