... ... @@ -118,11 +118,11 @@
118 118  BMS Mini devices: connection with cell monitor is lost.|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic offline|(% style="width:54px" %)LOF|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 9
119 119  |(% style="width:171px" %)Low temperature (CH)|(% style="width:324px" %)Temperature is too low for charging;|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Low temp. CH|(% style="width:54px" %)LTC|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 0
120 120  |(% style="width:171px" %)Low temperature (DCH)|(% style="width:324px" %)Temperature is too low for discharging;|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Low temp. DCH|(% style="width:54px" %)LTD|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 3
121 -|(% style="width:171px" %)Main contactor feedback error|(% style="width:324px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Main cont. feed.|(% style="width:54px" %)MCF|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 11. Off = 0, On = 1.
122 -|(% style="width:171px" %)Mount error|(% style="width:324px" %)SD card cannot be mounted|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Mount error|(% style="width:54px" %)MNT|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 2. Off = 0, On = 1.
123 -|(% style="width:171px" %)Need acknowledge|(% style="width:324px" %)There is an unacknowledged error in error journal|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Need ACK|(% style="width:54px" %)ACK|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 14. Off = 0, On = 1.
124 -|(% style="width:171px" %)No temperature sensors|(% style="width:324px" %)The device has no temperature sensors connected|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)No temp. sens.|(% style="width:54px" %)NTS|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 27. Off = 0, On = 1.
125 -|(% style="width:171px" %)Overcurrent|(% style="width:324px" %)The battery current is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Overcurrent|(% style="width:54px" %)OC|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 0. Off = 0, On = 1.
121 +|(% style="width:171px" %)Main contactor feedback error|(% style="width:324px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Main cont. feed.|(% style="width:54px" %)MCF|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 11
122 +|(% style="width:171px" %)Mount error|(% style="width:324px" %)SD card cannot be mounted|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Mount error|(% style="width:54px" %)MNT|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 2
123 +|(% style="width:171px" %)Need acknowledge|(% style="width:324px" %)There is an unacknowledged error in error journal|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Need ACK|(% style="width:54px" %)ACK|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 14
124 +|(% style="width:171px" %)No temperature sensors|(% style="width:324px" %)The device has no temperature sensors connected|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)No temp. sens.|(% style="width:54px" %)NTS|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 27
125 +|(% style="width:171px" %)Overcurrent|(% style="width:324px" %)The battery current is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Overcurrent|(% style="width:54px" %)OC|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 0
126 126  |(% style="width:171px" %)Overvoltage|(% style="width:324px" %)Voltage of any cell is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Overvoltage|(% style="width:54px" %)OV|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 2. Off = 0, On = 1.
127 127  |(% style="width:171px" %)PCH contactor feedback error|(% style="width:324px" %)The control signal for the precharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)PCH cont. feed.|(% style="width:54px" %)PCF|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 9. Off = 0, On = 1.
128 128  |(% style="width:171px" %)Power fault|(% style="width:324px" %)External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)Power fault|(% style="width:54px" %)PF|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 18. Off = 0, On = 1.