Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,27 +9,27 @@ 9 9 |=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 399px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 223px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 216px;" %)BMS DIsplay|=(% colspan="1" rowspan="2" style="width: 236px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 268px;" %)**Modbus** 10 10 |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 69px;" %)**Main 2.1**|=(% style="width: 59px;" %)**Main 3**|=(% colspan="1" style="width: 123px;" %)Short name|=(% style="width: 93px;" %)Abbreviation 11 11 |Balancing request|(% style="width:399px" %)Request to balance the cells|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Balancing req.|(% style="width:93px" %)BR|(% style="width:236px" %) |(% style="width:268px" %) 12 -|Battery cover|(% style="width:399px" %)Signal from the battery cover|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Battery cover|(% style="width:93px" %)CVR|(% style="width:236px" %) |(% style="width:268px" %)0x2000, bit 0. Off =13 -|CH contactor feedback|(% style="width:399px" %)Signal from the charging contactor feedback loop|(% style="width:94px" %)Yes*|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)CH cont. feed.|(% style="width:93px" %)CCF|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 5. Off = 0, On = 1.14 -|CH/DCH contactor feedback|(% style="width:399px" %)Signal from the charging/discharging contactor feedback loop|(% style="width:94px" %)Yes*|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)C/D cont. feed.|(% style="width:93px" %)CDF|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 12. Off = 0, On = 1.15 -|Charge request|(% style="width:399px" %)Request to close the charging contactor|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Charge request|(% style="width:93px" %)CRE|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 8. Off = 0, On = 1.16 -|Charger connected|(% style="width:399px" %)Signal indicating that the charger is connected|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Charger connect.|(% style="width:93px" %)CON|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 1. Off = 0, On = 1.12 +|Battery cover|(% style="width:399px" %)Signal from the battery cover|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Battery cover|(% style="width:93px" %)CVR|(% style="width:236px" %) |(% style="width:268px" %)0x2000, bit 5. Off =0, On = 1. 13 +|CH contactor feedback|(% style="width:399px" %)Signal from the charging contactor feedback loop|(% style="width:94px" %)Yes*|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)CH cont. feed.|(% style="width:93px" %)CCF|(% style="width:236px" %) |(% style="width:268px" %) 14 +|CH/DCH contactor feedback|(% style="width:399px" %)Signal from the charging/discharging contactor feedback loop|(% style="width:94px" %)Yes*|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)C/D cont. feed.|(% style="width:93px" %)CDF|(% style="width:236px" %) |(% style="width:268px" %) 15 +|Charge request|(% style="width:399px" %)Request to close the charging contactor|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Charge request|(% style="width:93px" %)CRE|(% style="width:236px" %) |(% style="width:268px" %) 16 +|Charger connected|(% style="width:399px" %)Signal indicating that the charger is connected|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Charger connect.|(% style="width:93px" %)CON|(% style="width:236px" %) |(% style="width:268px" %) 17 17 |Circuit breaker status|(% style="width:399px" %)Status of protective disconnector|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Circuit breaker|(% style="width:93px" %)CBS|(% style="width:236px" %) |(% style="width:268px" %) 18 18 |Close External 1|(% style="width:399px" %)Request to set the External 1 signal|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Close Ext.1|(% style="width:93px" %)CE1|(% style="width:236px" %) |(% style="width:268px" %) 19 19 |Close Main contactor|(% style="width:399px" %)Request to close the main contactor|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Close Main cont.|(% style="width:93px" %)CMC|(% style="width:236px" %) |(% style="width:268px" %) 20 -|DCH contactor feedback|(% style="width:399px" %)Signal from the discharging contactor feedback loop|(% style="width:94px" %)Yes*|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)DCH cont. feed.|(% style="width:93px" %)DCF|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 6. Off = 0, On = 1.21 -|Discharge request|(% style="width:399px" %)Request to close the discharging contactor|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Discharge req.|(% style="width:93px" %)DRE|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 10. Off = 0, On = 1.22 -|Fuse 1|(% style="width:399px" %)Signal from fuse 1|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Fuse 1|(% style="width:93px" %)F1|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 14. Off = 0, On = 1.23 -|Fuse 2|(% style="width:399px" %)Signal from fuse 2|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Fuse 2|(% style="width:93px" %)F2|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 1. Off = 0, On = 1.20 +|DCH contactor feedback|(% style="width:399px" %)Signal from the discharging contactor feedback loop|(% style="width:94px" %)Yes*|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)DCH cont. feed.|(% style="width:93px" %)DCF|(% style="width:236px" %) |(% style="width:268px" %) 21 +|Discharge request|(% style="width:399px" %)Request to close the discharging contactor|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Discharge req.|(% style="width:93px" %)DRE|(% style="width:236px" %) |(% style="width:268px" %) 22 +|Fuse 1|(% style="width:399px" %)Signal from fuse 1|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Fuse 1|(% style="width:93px" %)F1|(% style="width:236px" %) |(% style="width:268px" %) 23 +|Fuse 2|(% style="width:399px" %)Signal from fuse 2|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Fuse 2|(% style="width:93px" %)F2|(% style="width:236px" %) |(% style="width:268px" %) 24 24 |Fuse 3|(% style="width:399px" %)Signal from fuse 3|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Fuse 3|(% style="width:93px" %)F3|(% style="width:236px" %) |(% style="width:268px" %) 25 -|Inhibit charging|(% style="width:399px" %)Command to open the charging contactor|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Inhibit charg.|(% style="width:93px" %)ICH|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 3. Off = 0, On = 1.26 -|Inhibit discharging|(% style="width:399px" %)Command to open the discharging contactor|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Inhibit disch.|(% style="width:93px" %)IDC|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 4. Off = 0, On = 1.27 -|Insulation status|(% style="width:399px" %)Signal from an insulation monitoring device|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Insul. status|(% style="width:93px" %)INS|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 7. Off = 0, On = 1.28 -|Interlock|(% style="width:399px" %)Signal from the interlock loop|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Interlock|(% style="width:93px" %)INT|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 14. Off = 0, On = 1.29 -|Main contactor feedback|(% style="width:399px" %)Signal from the main contactor feedback loop|(% style="width:94px" %)Yes*|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Main cont. feed.|(% style="width:93px" %)MCF|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 13. Off = 0, On = 1.30 -|PCH contactor feedback|(% style="width:399px" %)Signal from the precharging contactor feedback loop|(% style="width:94px" %)Yes*|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)PCH cont. feed.|(% style="width:93px" %)PCF|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 11. Off = 0, On = 1.31 -|Power up/down request|(% style="width:399px" %)Request to power down the device|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Power down req.|(% style="width:93px" %)PDN|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 2. Off = 0, On = 1.32 -|Precharge request|(% style="width:399px" %)Request to close the precharging contactor|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Precharge req.|(% style="width:93px" %)PRE|(% style="width:236px" %) |(% style="width:268px" %) 0x2000,bit 9. Off = 0, On = 1.25 +|Inhibit charging|(% style="width:399px" %)Command to open the charging contactor|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Inhibit charg.|(% style="width:93px" %)ICH|(% style="width:236px" %) |(% style="width:268px" %) 26 +|Inhibit discharging|(% style="width:399px" %)Command to open the discharging contactor|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Inhibit disch.|(% style="width:93px" %)IDC|(% style="width:236px" %) |(% style="width:268px" %) 27 +|Insulation status|(% style="width:399px" %)Signal from an insulation monitoring device|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Insul. status|(% style="width:93px" %)INS|(% style="width:236px" %) |(% style="width:268px" %) 28 +|Interlock|(% style="width:399px" %)Signal from the interlock loop|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Interlock|(% style="width:93px" %)INT|(% style="width:236px" %) |(% style="width:268px" %) 29 +|Main contactor feedback|(% style="width:399px" %)Signal from the main contactor feedback loop|(% style="width:94px" %)Yes*|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Main cont. feed.|(% style="width:93px" %)MCF|(% style="width:236px" %) |(% style="width:268px" %) 30 +|PCH contactor feedback|(% style="width:399px" %)Signal from the precharging contactor feedback loop|(% style="width:94px" %)Yes*|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)PCH cont. feed.|(% style="width:93px" %)PCF|(% style="width:236px" %) |(% style="width:268px" %) 31 +|Power up/down request|(% style="width:399px" %)Request to power down the device|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Power down req.|(% style="width:93px" %)PDN|(% style="width:236px" %) |(% style="width:268px" %) 32 +|Precharge request|(% style="width:399px" %)Request to close the precharging contactor|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Precharge req.|(% style="width:93px" %)PRE|(% style="width:236px" %) |(% style="width:268px" %) 33 33 34 34 (% class="wikigeneratedid" %) 35 35 ~* Contactor feedback signals in BMS Mini / BMS Mini S are connected to [[X1 header>>doc:Battery management systems.BMS Mini S.2\. Installation and connection.WebHome||anchor="HHeaders"]] and configured in "Signals → MOSFETs → Contactors feedback" section.