Last modified by Admin on 2025/03/03 15:20

From version 26.57
edited by Admin
on 2025/02/04 09:46
Change comment: There is no comment for this version
To version 26.58
edited by Admin
on 2025/02/04 09:46
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -115,7 +115,7 @@
115 115  |(% style="width:171px" %)Overcurrent|(% style="width:324px" %)The battery current is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Overcurrent|(% style="width:54px" %)OC|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 0. Off = 0, On = 1.
116 116  |(% style="width:171px" %)Overvoltage|(% style="width:324px" %)Voltage of any cell is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Overvoltage|(% style="width:54px" %)OV|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 2. Off = 0, On = 1.
117 117  |(% style="width:171px" %)PCH contactor feedback error|(% style="width:324px" %)The control signal for the precharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)PCH cont. feed.|(% style="width:54px" %)PCF|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 9. Off = 0, On = 1.
118 -|(% style="width:171px" %)Power fault|(% style="width:324px" %)External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)Power fault|(% style="width:54px" %)PF|(% style="width:265px" %) |(% style="width:306px" %)
118 +|(% style="width:171px" %)Power fault|(% style="width:324px" %)External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)Power fault|(% style="width:54px" %)PF|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 18. Off = 0, On = 1.
119 119  |(% style="width:171px" %)Power switch error|(% style="width:324px" %)Short circuit in contactor coil control circuit or power switch overheating|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)PSW error|(% style="width:54px" %)PSE|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 15. Off = 0, On = 1.
120 120  |(% style="width:171px" %)Precharge error|(% style="width:324px" %)Capacitive load pre-charge process did not end during the estimated time|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Precharge error|(% style="width:54px" %)PE|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 17. Off = 0, On = 1.
121 121  |(% style="width:171px" %)Settings error|(% style="width:324px" %)Wrong checksum of the device settings|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %) |(% style="width:126px" %)Settings err.|(% style="width:54px" %)SET|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 25. Off = 0, On = 1.