Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -91,7 +91,7 @@ 91 91 |(% style="width:171px" %)Current limit error|(% style="width:324px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)Cur. limit error|(% style="width:54px" %)CLE|(% style="width:265px" %) |(% style="width:306px" %) 92 92 |(% style="width:171px" %)Current sensor error|(% style="width:324px" %)Error in the current sensor circuit|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Current sensor|(% style="width:54px" %)CSE|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 20. Off = 0, On = 1. 93 93 |(% style="width:171px" %)DCH contactor cycles error|(% style="width:324px" %)Switching frequency of the discharging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)DCH cont. cycle|(% style="width:54px" %)DCC|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 22. Off = 0, On = 1. 94 -|(% style="width:171px" %)DCH contactor feedback error|(% style="width:324px" %)The control signal for the discharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)DCH cont. feed.|(% style="width:54px" %)DCF|(% style="width:265px" %) |(% style="width:306px" %) 0x200E-0x200F, bit7. Off = 0, On = 1.94 +|(% style="width:171px" %)DCH contactor feedback error|(% style="width:324px" %)The control signal for the discharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)DCH cont. feed.|(% style="width:54px" %)DCF|(% style="width:265px" %) |(% style="width:306px" %) 95 95 |(% style="width:171px" %)FS error|(% style="width:324px" %)SD card read/write error|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)FS error|(% style="width:54px" %)FSE|(% style="width:265px" %) |(% style="width:306px" %)0x200E-0x200F, bit 3. Off = 0, On = 1. 96 96 |(% style="width:171px" %)General error|(% style="width:324px" %)Special configurable error depending on other errors|(% style="width:61px" %) |(% style="width:92px" %)Yes*|(% style="width:66px" %)Yes*|(% style="width:56px" %)Yes*|(% style="width:126px" %)General error|(% style="width:54px" %)GE|(% style="width:265px" %) |(% style="width:306px" %) 97 97 |(% style="width:171px" %)High contactor temperature|(% style="width:324px" %)Temperature of a contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. cont. temp.|(% style="width:54px" %)HCT|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 17. Off = 0, On = 1. ... ... @@ -102,7 +102,7 @@ 102 102 |(% style="width:171px" %)High voltage fault|(% style="width:324px" %)Failure of high voltage measuring circuits|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)HV fault|(% style="width:54px" %)HVF|(% style="width:265px" %) |(% style="width:306px" %) 103 103 |(% style="width:171px" %)HVIL error|(% style="width:324px" %)Breakage of high-voltage interlock current loop|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)HVIL error|(% style="width:54px" %)HE|(% style="width:265px" %) |(% style="width:306px" %) 104 104 |(% style="width:171px" %)HYG offline|(% style="width:324px" %)Connection with the HYG forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)HYG offline|(% style="width:54px" %)HYG|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 13. Off = 0, On = 1. 105 -|(% style="width:171px" %)Insulation fault|(% style="width:324px" %)Insulation resistance is too low|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Insulation fault|(% style="width:54px" %)INF|(% style="width:265px" %) |(% style="width:306px" %) 0x200E-0x200F, bit8. Off = 0, On = 1.105 +|(% style="width:171px" %)Insulation fault|(% style="width:324px" %)Insulation resistance is too low|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Insulation fault|(% style="width:54px" %)INF|(% style="width:265px" %) |(% style="width:306px" %) 106 106 |(% style="width:171px" %)Logic count error|(% style="width:324px" %)The number of BMS Logic devices differs from the required value|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic count|(% style="width:54px" %)LOG|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 18. Off = 0, On = 1. 107 107 |(% style="width:171px" %)Logic offline (Cell monitor offline)|(% style="width:324px" %)BMS Main devices: at least one of the Logic devices is offline. 108 108 BMS Mini devices: connection with cell monitor is lost.|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic offline|(% style="width:54px" %)LOF|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 9. Off = 0, On = 1.