Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -120,7 +120,7 @@ 120 120 |(% style="width:171px" %)Precharge error|(% style="width:324px" %)Capacitive load pre-charge process did not end during the estimated time|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Precharge error|(% style="width:54px" %)PE|(% style="width:265px" %) |(% style="width:306px" %) 121 121 |(% style="width:171px" %)Settings error|(% style="width:324px" %)Wrong checksum of the device settings|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %) |(% style="width:126px" %)Settings err.|(% style="width:54px" %)SET|(% style="width:265px" %) |(% style="width:306px" %) 122 122 |(% style="width:171px" %)Short circuit|(% style="width:324px" %)Flowing high battery currents during a long time|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Short circuit|(% style="width:54px" %)SHC|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 16. Off = 0, On = 1. 123 -|(% style="width:171px" %)Shunt error|(% style="width:324px" %)Internal error of the shunt current sensor|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shunt error|(% style="width:54px" %)SHE|(% style="width:265px" %) |(% style="width:306px" %) 0x2007-0x2008, bit24. Off = 0, On = 1.123 +|(% style="width:171px" %)Shunt error|(% style="width:324px" %)Internal error of the shunt current sensor|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shunt error|(% style="width:54px" %)SHE|(% style="width:265px" %) |(% style="width:306px" %) 124 124 |(% style="width:171px" %)Shunt offline|(% style="width:324px" %)Connection with the shunt current sensor is lost|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shunt offline|(% style="width:54px" %)SHO|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 23. Off = 0, On = 1. 125 125 |(% style="width:171px" %)Spirit offline|(% style="width:324px" %)Connection with the Spirit forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Spirit offline|(% style="width:54px" %)SPI|(% style="width:265px" %) |(% style="width:306px" %) 126 126 |(% style="width:171px" %)Stuck contactor|(% style="width:324px" %)Some contactor got stuck|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Stuck contactor|(% style="width:54px" %)STC|(% style="width:265px" %) |(% style="width:306px" %)