Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -81,7 +81,7 @@ 81 81 |(% style="width:171px" %)ADC error|(% style="width:324px" %)Error of the ADC that measures the battery current|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)ADC error|(% style="width:54px" %)ADC|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 19. Off = 0, On = 1. 82 82 |(% style="width:171px" %)Battery cover error|(% style="width:324px" %)Battery cover is open|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Battery cover|(% style="width:54px" %)BCE|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 5. Off = 0, On = 1. 83 83 |(% style="width:171px" %)Cell count error|(% style="width:324px" %)Number of cells does not match the specified value|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Cell count|(% style="width:54px" %)CEL|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 12. Off = 0, On = 1. 84 -|(% style="width:171px" %)CH contactor cycles error|(% style="width:324px" %)Switching frequency of the charging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)CH cont. cycle|(% style="width:54px" %)CCC|(% style="width:265px" %) |(% style="width:306px" %) 84 +|(% style="width:171px" %)CH contactor cycles error|(% style="width:324px" %)Switching frequency of the charging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)CH cont. cycle|(% style="width:54px" %)CCC|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 21. Off = 0, On = 1. 85 85 |(% style="width:171px" %)CH contactor feedback error|(% style="width:324px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)CH cont. feed.|(% style="width:54px" %)CCF|(% style="width:265px" %) |(% style="width:306px" %) 86 86 |(% style="width:171px" %)CH/DCH contactor feedback error|(% style="width:324px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)C/D cont. feed.|(% style="width:54px" %)CDF|(% style="width:265px" %) |(% style="width:306px" %) 87 87 |(% style="width:171px" %)Combilift offline|(% style="width:324px" %)Connection with the Combilift forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Combilift offl.|(% style="width:54px" %)COM|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 15. Off = 0, On = 1. ... ... @@ -89,8 +89,8 @@ 89 89 |(% style="width:171px" %)Critical error|(% style="width:324px" %)Critical system error, the BMS is damaged|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Critical error|(% style="width:54px" %)CER|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 10. Off = 0, On = 1. 90 90 |(% style="width:171px" %)Crown error|(% style="width:324px" %)Connection with the Crown forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Crown error|(% style="width:54px" %)CRO|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 11. Off = 0, On = 1. 91 91 |(% style="width:171px" %)Current limit error|(% style="width:324px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)Cur. limit error|(% style="width:54px" %)CLE|(% style="width:265px" %) |(% style="width:306px" %) 92 -|(% style="width:171px" %)Current sensor error|(% style="width:324px" %)Error in the current sensor circuit|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Current sensor|(% style="width:54px" %)CSE|(% style="width:265px" %) |(% style="width:306px" %) 93 -|(% style="width:171px" %)DCH contactor cycles error|(% style="width:324px" %)Switching frequency of the discharging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)DCH cont. cycle|(% style="width:54px" %)DCC|(% style="width:265px" %) |(% style="width:306px" %) 92 +|(% style="width:171px" %)Current sensor error|(% style="width:324px" %)Error in the current sensor circuit|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Current sensor|(% style="width:54px" %)CSE|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 20. Off = 0, On = 1. 93 +|(% style="width:171px" %)DCH contactor cycles error|(% style="width:324px" %)Switching frequency of the discharging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)DCH cont. cycle|(% style="width:54px" %)DCC|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 22. Off = 0, On = 1. 94 94 |(% style="width:171px" %)DCH contactor feedback error|(% style="width:324px" %)The control signal for the discharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)DCH cont. feed.|(% style="width:54px" %)DCF|(% style="width:265px" %) |(% style="width:306px" %) 95 95 |(% style="width:171px" %)FS error|(% style="width:324px" %)SD card read/write error|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)FS error|(% style="width:54px" %)FSE|(% style="width:265px" %) |(% style="width:306px" %) 96 96 |(% style="width:171px" %)General error|(% style="width:324px" %)Special configurable error depending on other errors|(% style="width:61px" %) |(% style="width:92px" %)Yes*|(% style="width:66px" %)Yes*|(% style="width:56px" %)Yes*|(% style="width:126px" %)General error|(% style="width:54px" %)GE|(% style="width:265px" %) |(% style="width:306px" %) ... ... @@ -120,8 +120,8 @@ 120 120 |(% style="width:171px" %)Precharge error|(% style="width:324px" %)Capacitive load pre-charge process did not end during the estimated time|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Precharge error|(% style="width:54px" %)PE|(% style="width:265px" %) |(% style="width:306px" %) 121 121 |(% style="width:171px" %)Settings error|(% style="width:324px" %)Wrong checksum of the device settings|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %) |(% style="width:126px" %)Settings err.|(% style="width:54px" %)SET|(% style="width:265px" %) |(% style="width:306px" %) 122 122 |(% style="width:171px" %)Short circuit|(% style="width:324px" %)Flowing high battery currents during a long time|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Short circuit|(% style="width:54px" %)SHC|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 16. Off = 0, On = 1. 123 -|(% style="width:171px" %)Shunt error|(% style="width:324px" %)Internal error of the shunt current sensor|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shunt error|(% style="width:54px" %)SHE|(% style="width:265px" %) |(% style="width:306px" %) 124 -|(% style="width:171px" %)Shunt offline|(% style="width:324px" %)Connection with the shunt current sensor is lost|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shunt offline|(% style="width:54px" %)SHO|(% style="width:265px" %) |(% style="width:306px" %) 123 +|(% style="width:171px" %)Shunt error|(% style="width:324px" %)Internal error of the shunt current sensor|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shunt error|(% style="width:54px" %)SHE|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 24. Off = 0, On = 1. 124 +|(% style="width:171px" %)Shunt offline|(% style="width:324px" %)Connection with the shunt current sensor is lost|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shunt offline|(% style="width:54px" %)SHO|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 23. Off = 0, On = 1. 125 125 |(% style="width:171px" %)Spirit offline|(% style="width:324px" %)Connection with the Spirit forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Spirit offline|(% style="width:54px" %)SPI|(% style="width:265px" %) |(% style="width:306px" %) 126 126 |(% style="width:171px" %)Stuck contactor|(% style="width:324px" %)Some contactor got stuck|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Stuck contactor|(% style="width:54px" %)STC|(% style="width:265px" %) |(% style="width:306px" %) 127 127 |(% style="width:171px" %)Temperature sensor is shorted|(% style="width:324px" %)Some temperature sensors are shorted|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shorted temp.|(% style="width:54px" %)TSS|(% style="width:265px" %) |(% style="width:306px" %)