Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -78,7 +78,7 @@ 78 78 (% style="width:1533px" %) 79 79 |(% colspan="1" rowspan="2" style="width:171px" %)**Name **|(% colspan="1" rowspan="2" style="width:324px" %)**Description**|(% colspan="1" rowspan="2" style="width:61px" %)**Is a critical error?**|(% colspan="3" rowspan="1" style="width:215px" %)**Compability**|(% colspan="2" rowspan="1" style="width:180px" %)**BMS Display**|(% colspan="1" rowspan="2" style="width:265px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:306px" %)**Modbus** 80 80 |=(% style="width: 92px;" %)**Mini S / Mini**|=(% style="width: 66px;" %)**Main 2.1**|=(% style="width: 56px;" %)**Main 3**|=(% colspan="1" style="width: 126px;" %)Short name|=(% style="width: 54px;" %)Abbr. 81 -|(% style="width:171px" %)ADC error|(% style="width:324px" %)Error of the ADC that measures the battery current|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)ADC error|(% style="width:54px" %)ADC|(% style="width:265px" %) |(% style="width:306px" %) 0x2007-0x2008, bit19. Off = 0, On = 1.81 +|(% style="width:171px" %)ADC error|(% style="width:324px" %)Error of the ADC that measures the battery current|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)ADC error|(% style="width:54px" %)ADC|(% style="width:265px" %) |(% style="width:306px" %) 82 82 |(% style="width:171px" %)Battery cover error|(% style="width:324px" %)Battery cover is open|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Battery cover|(% style="width:54px" %)BCE|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 5. Off = 0, On = 1. 83 83 |(% style="width:171px" %)Cell count error|(% style="width:324px" %)Number of cells does not match the specified value|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Cell count|(% style="width:54px" %)CEL|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 12. Off = 0, On = 1. 84 84 |(% style="width:171px" %)CH contactor cycles error|(% style="width:324px" %)Switching frequency of the charging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)CH cont. cycle|(% style="width:54px" %)CCC|(% style="width:265px" %) |(% style="width:306px" %)