Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -103,7 +103,7 @@ 103 103 |(% style="width:171px" %)HVIL error|(% style="width:324px" %)Breakage of high-voltage interlock current loop|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)HVIL error|(% style="width:54px" %)HE|(% style="width:265px" %) |(% style="width:306px" %) 104 104 |(% style="width:171px" %)HYG offline|(% style="width:324px" %)Connection with the HYG forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)HYG offline|(% style="width:54px" %)HYG|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 13. Off = 0, On = 1. 105 105 |(% style="width:171px" %)Insulation fault|(% style="width:324px" %)Insulation resistance is too low|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Insulation fault|(% style="width:54px" %)INF|(% style="width:265px" %) |(% style="width:306px" %) 106 -|(% style="width:171px" %)Logic count error|(% style="width:324px" %)The number of BMS Logic devices differs from the required value|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic count|(% style="width:54px" %)LOG|(% style="width:265px" %) |(% style="width:306px" %) 106 +|(% style="width:171px" %)Logic count error|(% style="width:324px" %)The number of BMS Logic devices differs from the required value|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic count|(% style="width:54px" %)LOG|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 18. Off = 0, On = 1. 107 107 |(% style="width:171px" %)Logic offline (Cell monitor offline)|(% style="width:324px" %)BMS Main devices: at least one of the Logic devices is offline. 108 108 BMS Mini devices: connection with cell monitor is lost.|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic offline|(% style="width:54px" %)LOF|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 9. Off = 0, On = 1. 109 109 |(% style="width:171px" %)Low temperature (CH)|(% style="width:324px" %)Temperature is too low for charging;|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Low temp. CH|(% style="width:54px" %)LTC|(% style="width:265px" %) |(% style="width:306px" %)