Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -94,7 +94,7 @@ 94 94 |(% style="width:171px" %)DCH contactor feedback error|(% style="width:324px" %)The control signal for the discharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)DCH cont. feed.|(% style="width:54px" %)DCF|(% style="width:265px" %) |(% style="width:306px" %) 95 95 |(% style="width:171px" %)FS error|(% style="width:324px" %)SD card read/write error|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)FS error|(% style="width:54px" %)FSE|(% style="width:265px" %) |(% style="width:306px" %) 96 96 |(% style="width:171px" %)General error|(% style="width:324px" %)Special configurable error depending on other errors|(% style="width:61px" %) |(% style="width:92px" %)Yes*|(% style="width:66px" %)Yes*|(% style="width:56px" %)Yes*|(% style="width:126px" %)General error|(% style="width:54px" %)GE|(% style="width:265px" %) |(% style="width:306px" %) 97 -|(% style="width:171px" %)High contactor temperature|(% style="width:324px" %)Temperature of a contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. cont. temp.|(% style="width:54px" %)HCT|(% style="width:265px" %) |(% style="width:306px" %) 97 +|(% style="width:171px" %)High contactor temperature|(% style="width:324px" %)Temperature of a contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. cont. temp.|(% style="width:54px" %)HCT|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 17. Off = 0, On = 1. 98 98 |(% style="width:171px" %)High humidity|(% style="width:324px" %)Increased humidity inside the battery|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High humidity|(% style="width:54px" %)HHU|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 6. Off = 0, On = 1. 99 99 |(% style="width:171px" %)High Logic temperature|(% style="width:324px" %)At least one of the Logic devices is overheated|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. Logic temp.|(% style="width:54px" %)HLT|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 8. Off = 0, On = 1. 100 100 |(% style="width:171px" %)High temperature (CH)|(% style="width:324px" %)Temperature is too high for charging|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High temp. CH|(% style="width:54px" %)HTC|(% style="width:265px" %) |(% style="width:306px" %) ... ... @@ -103,7 +103,7 @@ 103 103 |(% style="width:171px" %)HVIL error|(% style="width:324px" %)Breakage of high-voltage interlock current loop|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)HVIL error|(% style="width:54px" %)HE|(% style="width:265px" %) |(% style="width:306px" %) 104 104 |(% style="width:171px" %)HYG offline|(% style="width:324px" %)Connection with the HYG forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)HYG offline|(% style="width:54px" %)HYG|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 13. Off = 0, On = 1. 105 105 |(% style="width:171px" %)Insulation fault|(% style="width:324px" %)Insulation resistance is too low|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Insulation fault|(% style="width:54px" %)INF|(% style="width:265px" %) |(% style="width:306px" %) 106 -|(% style="width:171px" %)Logic count error|(% style="width:324px" %)The number of BMS Logic devices differs from the required value|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic count|(% style="width:54px" %)LOG|(% style="width:265px" %) |(% style="width:306px" %) 106 +|(% style="width:171px" %)Logic count error|(% style="width:324px" %)The number of BMS Logic devices differs from the required value|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic count|(% style="width:54px" %)LOG|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 18. Off = 0, On = 1. 107 107 |(% style="width:171px" %)Logic offline (Cell monitor offline)|(% style="width:324px" %)BMS Main devices: at least one of the Logic devices is offline. 108 108 BMS Mini devices: connection with cell monitor is lost.|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic offline|(% style="width:54px" %)LOF|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 9. Off = 0, On = 1. 109 109 |(% style="width:171px" %)Low temperature (CH)|(% style="width:324px" %)Temperature is too low for charging;|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Low temp. CH|(% style="width:54px" %)LTC|(% style="width:265px" %) |(% style="width:306px" %) ... ... @@ -119,7 +119,7 @@ 119 119 |(% style="width:171px" %)Power switch error|(% style="width:324px" %)Short circuit in contactor coil control circuit or power switch overheating|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)PSW error|(% style="width:54px" %)PSE|(% style="width:265px" %) |(% style="width:306px" %) 120 120 |(% style="width:171px" %)Precharge error|(% style="width:324px" %)Capacitive load pre-charge process did not end during the estimated time|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Precharge error|(% style="width:54px" %)PE|(% style="width:265px" %) |(% style="width:306px" %) 121 121 |(% style="width:171px" %)Settings error|(% style="width:324px" %)Wrong checksum of the device settings|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %) |(% style="width:126px" %)Settings err.|(% style="width:54px" %)SET|(% style="width:265px" %) |(% style="width:306px" %) 122 -|(% style="width:171px" %)Short circuit|(% style="width:324px" %)Flowing high battery currents during a long time|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Short circuit|(% style="width:54px" %)SHC|(% style="width:265px" %) |(% style="width:306px" %) 122 +|(% style="width:171px" %)Short circuit|(% style="width:324px" %)Flowing high battery currents during a long time|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Short circuit|(% style="width:54px" %)SHC|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 16. Off = 0, On = 1. 123 123 |(% style="width:171px" %)Shunt error|(% style="width:324px" %)Internal error of the shunt current sensor|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shunt error|(% style="width:54px" %)SHE|(% style="width:265px" %) |(% style="width:306px" %) 124 124 |(% style="width:171px" %)Shunt offline|(% style="width:324px" %)Connection with the shunt current sensor is lost|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shunt offline|(% style="width:54px" %)SHO|(% style="width:265px" %) |(% style="width:306px" %) 125 125 |(% style="width:171px" %)Spirit offline|(% style="width:324px" %)Connection with the Spirit forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Spirit offline|(% style="width:54px" %)SPI|(% style="width:265px" %) |(% style="width:306px" %)