... ... @@ -84,7 +84,7 @@
84 84  |(% style="width:171px" %)CH contactor cycles error|(% style="width:324px" %)Switching frequency of the charging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)CH cont. cycle|(% style="width:54px" %)CCC|(% style="width:265px" %) |(% style="width:306px" %)
85 85  |(% style="width:171px" %)CH contactor feedback error|(% style="width:324px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)CH cont. feed.|(% style="width:54px" %)CCF|(% style="width:265px" %) |(% style="width:306px" %)
86 86  |(% style="width:171px" %)CH/DCH contactor feedback error|(% style="width:324px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)C/D cont. feed.|(% style="width:54px" %)CDF|(% style="width:265px" %) |(% style="width:306px" %)
87 -|(% style="width:171px" %)Combilift offline|(% style="width:324px" %)Connection with the Combilift forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Combilift offl.|(% style="width:54px" %)COM|(% style="width:265px" %) |(% style="width:306px" %)
87 +|(% style="width:171px" %)Combilift offline|(% style="width:324px" %)Connection with the Combilift forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Combilift offl.|(% style="width:54px" %)COM|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 15. Off = 0, On = 1.
88 88  |(% style="width:171px" %)Contactor feedback error|(% style="width:324px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %) |(% style="width:56px" %) |(% style="width:126px" %)Cont. feed. er.|(% style="width:54px" %)CFE|(% style="width:265px" %) |(% style="width:306px" %)
89 89  |(% style="width:171px" %)Critical error|(% style="width:324px" %)Critical system error, the BMS is damaged|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Critical error|(% style="width:54px" %)CER|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 10. Off = 0, On = 1.
90 90  |(% style="width:171px" %)Crown error|(% style="width:324px" %)Connection with the Crown forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Crown error|(% style="width:54px" %)CRO|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 11. Off = 0, On = 1.