Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -101,7 +101,7 @@ 101 101 |(% style="width:171px" %)High temperature (DCH)|(% style="width:324px" %)Temperature is too high for discharging|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High temp. DCH|(% style="width:54px" %)HTD|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 4. Off = 0, On = 1. 102 102 |(% style="width:171px" %)High voltage fault|(% style="width:324px" %)Failure of high voltage measuring circuits|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)HV fault|(% style="width:54px" %)HVF|(% style="width:265px" %) |(% style="width:306px" %) 103 103 |(% style="width:171px" %)HVIL error|(% style="width:324px" %)Breakage of high-voltage interlock current loop|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)HVIL error|(% style="width:54px" %)HE|(% style="width:265px" %) |(% style="width:306px" %) 104 -|(% style="width:171px" %)HYG offline|(% style="width:324px" %)Connection with the HYG forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)HYG offline|(% style="width:54px" %)HYG|(% style="width:265px" %) |(% style="width:306px" %) 104 +|(% style="width:171px" %)HYG offline|(% style="width:324px" %)Connection with the HYG forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)HYG offline|(% style="width:54px" %)HYG|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 13. Off = 0, On = 1. 105 105 |(% style="width:171px" %)Insulation fault|(% style="width:324px" %)Insulation resistance is too low|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Insulation fault|(% style="width:54px" %)INF|(% style="width:265px" %) |(% style="width:306px" %) 106 106 |(% style="width:171px" %)Logic count error|(% style="width:324px" %)The number of BMS Logic devices differs from the required value|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic count|(% style="width:54px" %)LOG|(% style="width:265px" %) |(% style="width:306px" %) 107 107 |(% style="width:171px" %)Logic offline (Cell monitor offline)|(% style="width:324px" %)BMS Main devices: at least one of the Logic devices is offline. ... ... @@ -110,7 +110,7 @@ 110 110 |(% style="width:171px" %)Low temperature (DCH)|(% style="width:324px" %)Temperature is too low for discharging;|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Low temp. DCH|(% style="width:54px" %)LTD|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 3. Off = 0, On = 1. 111 111 |(% style="width:171px" %)Main contactor feedback error|(% style="width:324px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Main cont. feed.|(% style="width:54px" %)MCF|(% style="width:265px" %) |(% style="width:306px" %) 112 112 |(% style="width:171px" %)Mount error|(% style="width:324px" %)SD card cannot be mounted|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Mount error|(% style="width:54px" %)MNT|(% style="width:265px" %) |(% style="width:306px" %) 113 -|(% style="width:171px" %)Need acknowledge|(% style="width:324px" %)There is an unacknowledged error in error journal|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Need ACK|(% style="width:54px" %)ACK|(% style="width:265px" %) |(% style="width:306px" %) 113 +|(% style="width:171px" %)Need acknowledge|(% style="width:324px" %)There is an unacknowledged error in error journal|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Need ACK|(% style="width:54px" %)ACK|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 14. Off = 0, On = 1. 114 114 |(% style="width:171px" %)No temperature sensors|(% style="width:324px" %)The device has no temperature sensors connected|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)No temp. sens.|(% style="width:54px" %)NTS|(% style="width:265px" %) |(% style="width:306px" %) 115 115 |(% style="width:171px" %)Overcurrent|(% style="width:324px" %)The battery current is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Overcurrent|(% style="width:54px" %)OC|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 0. Off = 0, On = 1. 116 116 |(% style="width:171px" %)Overvoltage|(% style="width:324px" %)Voltage of any cell is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Overvoltage|(% style="width:54px" %)OV|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 2. Off = 0, On = 1.