Last modified by Admin on 2025/03/03 15:20

From version 26.29
edited by Admin
on 2025/02/04 09:31
Change comment: There is no comment for this version
To version 26.25
edited by Admin
on 2025/02/04 09:30
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -80,14 +80,14 @@
80 80  |=(% style="width: 92px;" %)**Mini S / Mini**|=(% style="width: 66px;" %)**Main 2.1**|=(% style="width: 56px;" %)**Main 3**|=(% colspan="1" style="width: 126px;" %)Short name|=(% style="width: 54px;" %)Abbr.
81 81  |(% style="width:171px" %)ADC error|(% style="width:324px" %)Error of the ADC that measures the battery current|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)ADC error|(% style="width:54px" %)ADC|(% style="width:265px" %) |(% style="width:306px" %)
82 82  |(% style="width:171px" %)Battery cover error|(% style="width:324px" %)Battery cover is open|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Battery cover|(% style="width:54px" %)BCE|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 5. Off = 0, On = 1.
83 -|(% style="width:171px" %)Cell count error|(% style="width:324px" %)Number of cells does not match the specified value|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Cell count|(% style="width:54px" %)CEL|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 12. Off = 0, On = 1.
83 +|(% style="width:171px" %)Cell count error|(% style="width:324px" %)Number of cells does not match the specified value|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Cell count|(% style="width:54px" %)CEL|(% style="width:265px" %) |(% style="width:306px" %)
84 84  |(% style="width:171px" %)CH contactor cycles error|(% style="width:324px" %)Switching frequency of the charging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)CH cont. cycle|(% style="width:54px" %)CCC|(% style="width:265px" %) |(% style="width:306px" %)
85 85  |(% style="width:171px" %)CH contactor feedback error|(% style="width:324px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)CH cont. feed.|(% style="width:54px" %)CCF|(% style="width:265px" %) |(% style="width:306px" %)
86 86  |(% style="width:171px" %)CH/DCH contactor feedback error|(% style="width:324px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)C/D cont. feed.|(% style="width:54px" %)CDF|(% style="width:265px" %) |(% style="width:306px" %)
87 87  |(% style="width:171px" %)Combilift offline|(% style="width:324px" %)Connection with the Combilift forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Combilift offl.|(% style="width:54px" %)COM|(% style="width:265px" %) |(% style="width:306px" %)
88 88  |(% style="width:171px" %)Contactor feedback error|(% style="width:324px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %) |(% style="width:56px" %) |(% style="width:126px" %)Cont. feed. er.|(% style="width:54px" %)CFE|(% style="width:265px" %) |(% style="width:306px" %)
89 -|(% style="width:171px" %)Critical error|(% style="width:324px" %)Critical system error, the BMS is damaged|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Critical error|(% style="width:54px" %)CER|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 10. Off = 0, On = 1.
90 -|(% style="width:171px" %)Crown error|(% style="width:324px" %)Connection with the Crown forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Crown error|(% style="width:54px" %)CRO|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 11. Off = 0, On = 1.
89 +|(% style="width:171px" %)Critical error|(% style="width:324px" %)Critical system error, the BMS is damaged|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Critical error|(% style="width:54px" %)CER|(% style="width:265px" %) |(% style="width:306px" %)
90 +|(% style="width:171px" %)Crown error|(% style="width:324px" %)Connection with the Crown forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Crown error|(% style="width:54px" %)CRO|(% style="width:265px" %) |(% style="width:306px" %)
91 91  |(% style="width:171px" %)Current limit error|(% style="width:324px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)Cur. limit error|(% style="width:54px" %)CLE|(% style="width:265px" %) |(% style="width:306px" %)
92 92  |(% style="width:171px" %)Current sensor error|(% style="width:324px" %)Error in the current sensor circuit|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Current sensor|(% style="width:54px" %)CSE|(% style="width:265px" %) |(% style="width:306px" %)
93 93  |(% style="width:171px" %)DCH contactor cycles error|(% style="width:324px" %)Switching frequency of the discharging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)DCH cont. cycle|(% style="width:54px" %)DCC|(% style="width:265px" %) |(% style="width:306px" %)
... ... @@ -96,7 +96,7 @@
96 96  |(% style="width:171px" %)General error|(% style="width:324px" %)Special configurable error depending on other errors|(% style="width:61px" %) |(% style="width:92px" %)Yes*|(% style="width:66px" %)Yes*|(% style="width:56px" %)Yes*|(% style="width:126px" %)General error|(% style="width:54px" %)GE|(% style="width:265px" %) |(% style="width:306px" %)
97 97  |(% style="width:171px" %)High contactor temperature|(% style="width:324px" %)Temperature of a contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. cont. temp.|(% style="width:54px" %)HCT|(% style="width:265px" %) |(% style="width:306px" %)
98 98  |(% style="width:171px" %)High humidity|(% style="width:324px" %)Increased humidity inside the battery|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High humidity|(% style="width:54px" %)HHU|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 6. Off = 0, On = 1.
99 -|(% style="width:171px" %)High Logic temperature|(% style="width:324px" %)At least one of the Logic devices is overheated|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. Logic temp.|(% style="width:54px" %)HLT|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 8. Off = 0, On = 1.
99 +|(% style="width:171px" %)High Logic temperature|(% style="width:324px" %)At least one of the Logic devices is overheated|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. Logic temp.|(% style="width:54px" %)HLT|(% style="width:265px" %) |(% style="width:306px" %)
100 100  |(% style="width:171px" %)High temperature (CH)|(% style="width:324px" %)Temperature is too high for charging|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High temp. CH|(% style="width:54px" %)HTC|(% style="width:265px" %) |(% style="width:306px" %)
101 101  |(% style="width:171px" %)High temperature (DCH)|(% style="width:324px" %)Temperature is too high for discharging|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High temp. DCH|(% style="width:54px" %)HTD|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 4. Off = 0, On = 1.
102 102  |(% style="width:171px" %)High voltage fault|(% style="width:324px" %)Failure of high voltage measuring circuits|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)HV fault|(% style="width:54px" %)HVF|(% style="width:265px" %) |(% style="width:306px" %)
... ... @@ -105,7 +105,7 @@
105 105  |(% style="width:171px" %)Insulation fault|(% style="width:324px" %)Insulation resistance is too low|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Insulation fault|(% style="width:54px" %)INF|(% style="width:265px" %) |(% style="width:306px" %)
106 106  |(% style="width:171px" %)Logic count error|(% style="width:324px" %)The number of BMS Logic devices differs from the required value|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic count|(% style="width:54px" %)LOG|(% style="width:265px" %) |(% style="width:306px" %)
107 107  |(% style="width:171px" %)Logic offline (Cell monitor offline)|(% style="width:324px" %)BMS Main devices: at least one of the Logic devices is offline.
108 -BMS Mini devices: connection with cell monitor is lost.|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic offline|(% style="width:54px" %)LOF|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 9. Off = 0, On = 1.
108 +BMS Mini devices: connection with cell monitor is lost.|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic offline|(% style="width:54px" %)LOF|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 5. Off = 0, On = 1.
109 109  |(% style="width:171px" %)Low temperature (CH)|(% style="width:324px" %)Temperature is too low for charging;|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Low temp. CH|(% style="width:54px" %)LTC|(% style="width:265px" %) |(% style="width:306px" %)
110 110  |(% style="width:171px" %)Low temperature (DCH)|(% style="width:324px" %)Temperature is too low for discharging;|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Low temp. DCH|(% style="width:54px" %)LTD|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 3. Off = 0, On = 1.
111 111  |(% style="width:171px" %)Main contactor feedback error|(% style="width:324px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Main cont. feed.|(% style="width:54px" %)MCF|(% style="width:265px" %) |(% style="width:306px" %)