Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -86,8 +86,8 @@ 86 86 |(% style="width:171px" %)CH/DCH contactor feedback error|(% style="width:324px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)C/D cont. feed.|(% style="width:54px" %)CDF|(% style="width:265px" %) |(% style="width:306px" %) 87 87 |(% style="width:171px" %)Combilift offline|(% style="width:324px" %)Connection with the Combilift forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Combilift offl.|(% style="width:54px" %)COM|(% style="width:265px" %) |(% style="width:306px" %) 88 88 |(% style="width:171px" %)Contactor feedback error|(% style="width:324px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %) |(% style="width:56px" %) |(% style="width:126px" %)Cont. feed. er.|(% style="width:54px" %)CFE|(% style="width:265px" %) |(% style="width:306px" %) 89 -|(% style="width:171px" %)Critical error|(% style="width:324px" %)Critical system error, the BMS is damaged|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Critical error|(% style="width:54px" %)CER|(% style="width:265px" %) |(% style="width:306px" %) 0x2007-0x2008, bit10. Off = 0, On = 1.90 -|(% style="width:171px" %)Crown error|(% style="width:324px" %)Connection with the Crown forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Crown error|(% style="width:54px" %)CRO|(% style="width:265px" %) |(% style="width:306px" %) 0x2007-0x2008, bit11. Off = 0, On = 1.89 +|(% style="width:171px" %)Critical error|(% style="width:324px" %)Critical system error, the BMS is damaged|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Critical error|(% style="width:54px" %)CER|(% style="width:265px" %) |(% style="width:306px" %) 90 +|(% style="width:171px" %)Crown error|(% style="width:324px" %)Connection with the Crown forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Crown error|(% style="width:54px" %)CRO|(% style="width:265px" %) |(% style="width:306px" %) 91 91 |(% style="width:171px" %)Current limit error|(% style="width:324px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)Cur. limit error|(% style="width:54px" %)CLE|(% style="width:265px" %) |(% style="width:306px" %) 92 92 |(% style="width:171px" %)Current sensor error|(% style="width:324px" %)Error in the current sensor circuit|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Current sensor|(% style="width:54px" %)CSE|(% style="width:265px" %) |(% style="width:306px" %) 93 93 |(% style="width:171px" %)DCH contactor cycles error|(% style="width:324px" %)Switching frequency of the discharging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)DCH cont. cycle|(% style="width:54px" %)DCC|(% style="width:265px" %) |(% style="width:306px" %) ... ... @@ -96,7 +96,7 @@ 96 96 |(% style="width:171px" %)General error|(% style="width:324px" %)Special configurable error depending on other errors|(% style="width:61px" %) |(% style="width:92px" %)Yes*|(% style="width:66px" %)Yes*|(% style="width:56px" %)Yes*|(% style="width:126px" %)General error|(% style="width:54px" %)GE|(% style="width:265px" %) |(% style="width:306px" %) 97 97 |(% style="width:171px" %)High contactor temperature|(% style="width:324px" %)Temperature of a contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. cont. temp.|(% style="width:54px" %)HCT|(% style="width:265px" %) |(% style="width:306px" %) 98 98 |(% style="width:171px" %)High humidity|(% style="width:324px" %)Increased humidity inside the battery|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High humidity|(% style="width:54px" %)HHU|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 6. Off = 0, On = 1. 99 -|(% style="width:171px" %)High Logic temperature|(% style="width:324px" %)At least one of the Logic devices is overheated|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. Logic temp.|(% style="width:54px" %)HLT|(% style="width:265px" %) |(% style="width:306px" %) 0x2007-0x2008, bit8. Off = 0, On = 1.99 +|(% style="width:171px" %)High Logic temperature|(% style="width:324px" %)At least one of the Logic devices is overheated|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. Logic temp.|(% style="width:54px" %)HLT|(% style="width:265px" %) |(% style="width:306px" %) 100 100 |(% style="width:171px" %)High temperature (CH)|(% style="width:324px" %)Temperature is too high for charging|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High temp. CH|(% style="width:54px" %)HTC|(% style="width:265px" %) |(% style="width:306px" %) 101 101 |(% style="width:171px" %)High temperature (DCH)|(% style="width:324px" %)Temperature is too high for discharging|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High temp. DCH|(% style="width:54px" %)HTD|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 4. Off = 0, On = 1. 102 102 |(% style="width:171px" %)High voltage fault|(% style="width:324px" %)Failure of high voltage measuring circuits|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)HV fault|(% style="width:54px" %)HVF|(% style="width:265px" %) |(% style="width:306px" %) ... ... @@ -105,7 +105,7 @@ 105 105 |(% style="width:171px" %)Insulation fault|(% style="width:324px" %)Insulation resistance is too low|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Insulation fault|(% style="width:54px" %)INF|(% style="width:265px" %) |(% style="width:306px" %) 106 106 |(% style="width:171px" %)Logic count error|(% style="width:324px" %)The number of BMS Logic devices differs from the required value|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic count|(% style="width:54px" %)LOG|(% style="width:265px" %) |(% style="width:306px" %) 107 107 |(% style="width:171px" %)Logic offline (Cell monitor offline)|(% style="width:324px" %)BMS Main devices: at least one of the Logic devices is offline. 108 -BMS Mini devices: connection with cell monitor is lost.|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic offline|(% style="width:54px" %)LOF|(% style="width:265px" %) |(% style="width:306px" %) 0x2007-0x2008, bit9. Off = 0, On = 1.108 +BMS Mini devices: connection with cell monitor is lost.|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic offline|(% style="width:54px" %)LOF|(% style="width:265px" %) |(% style="width:306px" %) 109 109 |(% style="width:171px" %)Low temperature (CH)|(% style="width:324px" %)Temperature is too low for charging;|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Low temp. CH|(% style="width:54px" %)LTC|(% style="width:265px" %) |(% style="width:306px" %) 110 110 |(% style="width:171px" %)Low temperature (DCH)|(% style="width:324px" %)Temperature is too low for discharging;|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Low temp. DCH|(% style="width:54px" %)LTD|(% style="width:265px" %) |(% style="width:306px" %)0x2007-0x2008, bit 3. Off = 0, On = 1. 111 111 |(% style="width:171px" %)Main contactor feedback error|(% style="width:324px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Main cont. feed.|(% style="width:54px" %)MCF|(% style="width:265px" %) |(% style="width:306px" %)