... ... @@ -76,58 +76,58 @@
76 76  == Errors ==
77 77  
78 78  (% style="width:1533px" %)
79 -|(% colspan="1" rowspan="2" style="width:171px" %)**Name **|(% colspan="1" rowspan="2" style="width:263px" %)**Description**|(% colspan="1" rowspan="2" style="width:116px" %)**Is a critical error?**|(% colspan="3" rowspan="1" style="width:190px" %)**Compability**|(% colspan="2" rowspan="1" style="width:193px" %)**BMS Display**|(% colspan="1" rowspan="2" style="width:283px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:306px" %)**Modbus**
80 -|=(% style="width: 34px;" %)**Mini S / Mini**|=(% style="width: 76px;" %)**Main 2.1**|=(% style="width: 80px;" %)**Main 3**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 51px;" %)Abbr.
81 -|(% style="width:171px" %)ADC error|(% style="width:263px" %)Error of the ADC that measures the battery current|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)ADC error|(% style="width:51px" %)ADC|(% style="width:283px" %) |(% style="width:306px" %)
82 -|(% style="width:171px" %)Battery cover error|(% style="width:263px" %)Battery cover is open|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Battery cover|(% style="width:51px" %)BCE|(% style="width:283px" %) |(% style="width:306px" %)
83 -|(% style="width:171px" %)Cell count error|(% style="width:263px" %)Number of cells does not match the specified value|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Cell count|(% style="width:51px" %)CEL|(% style="width:283px" %) |(% style="width:306px" %)
84 -|(% style="width:171px" %)CH contactor cycles error|(% style="width:263px" %)Switching frequency of the charging contactor is too high|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)CH cont. cycle|(% style="width:51px" %)CCC|(% style="width:283px" %) |(% style="width:306px" %)
85 -|(% style="width:171px" %)CH contactor feedback error|(% style="width:263px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="width:116px" %)Yes|(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)CH cont. feed.|(% style="width:51px" %)CCF|(% style="width:283px" %) |(% style="width:306px" %)
86 -|(% style="width:171px" %)CH/DCH contactor feedback error|(% style="width:263px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:116px" %)Yes|(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)C/D cont. feed.|(% style="width:51px" %)CDF|(% style="width:283px" %) |(% style="width:306px" %)
87 -|(% style="width:171px" %)Combilift offline|(% style="width:263px" %)Connection with the Combilift forklift is lost|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Combilift offl.|(% style="width:51px" %)COM|(% style="width:283px" %) |(% style="width:306px" %)
88 -|(% style="width:171px" %)Contactor feedback error|(% style="width:263px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="width:116px" %) |(% style="width:34px" %)Yes| | |(% style="width:142px" %)Cont. feed. er.|(% style="width:51px" %)CFE|(% style="width:283px" %) |(% style="width:306px" %)
89 -|(% style="width:171px" %)Critical error|(% style="width:263px" %)Critical system error, the BMS is damaged|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Critical error|(% style="width:51px" %)CER|(% style="width:283px" %) |(% style="width:306px" %)
90 -|(% style="width:171px" %)Crown error|(% style="width:263px" %)Connection with the Crown forklift is lost|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Crown error|(% style="width:51px" %)CRO|(% style="width:283px" %) |(% style="width:306px" %)
91 -|(% style="width:171px" %)Current limit error|(% style="width:263px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:116px" %) |(% style="width:34px" %)Yes| |Yes|(% style="width:142px" %)Cur. limit error|(% style="width:51px" %)CLE|(% style="width:283px" %) |(% style="width:306px" %)
92 -|(% style="width:171px" %)Current sensor error|(% style="width:263px" %)Error in the current sensor circuit|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Current sensor|(% style="width:51px" %)CSE|(% style="width:283px" %) |(% style="width:306px" %)
93 -|(% style="width:171px" %)DCH contactor cycles error|(% style="width:263px" %)Switching frequency of the discharging contactor is too high|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)DCH cont. cycle|(% style="width:51px" %)DCC|(% style="width:283px" %) |(% style="width:306px" %)
94 -|(% style="width:171px" %)DCH contactor feedback error|(% style="width:263px" %)The control signal for the discharging contactor and the contactor feedback differ|(% style="width:116px" %)Yes|(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)DCH cont. feed.|(% style="width:51px" %)DCF|(% style="width:283px" %) |(% style="width:306px" %)
95 -|(% style="width:171px" %)FS error|(% style="width:263px" %)SD card read/write error|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)FS error|(% style="width:51px" %)FSE|(% style="width:283px" %) |(% style="width:306px" %)
96 -|(% style="width:171px" %)General error|(% style="width:263px" %)Special configurable error depending on other errors|(% style="width:116px" %) |(% style="width:34px" %)Yes*|Yes*|Yes*|(% style="width:142px" %)General error|(% style="width:51px" %)GE|(% style="width:283px" %) |(% style="width:306px" %)
97 -|(% style="width:171px" %)High contactor temperature|(% style="width:263px" %)Temperature of a contactor is too high|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Hi. cont. temp.|(% style="width:51px" %)HCT|(% style="width:283px" %) |(% style="width:306px" %)
98 -|(% style="width:171px" %)High humidity|(% style="width:263px" %)Increased humidity inside the battery|(% style="width:116px" %) |(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)High humidity|(% style="width:51px" %)HHU|(% style="width:283px" %) |(% style="width:306px" %)
99 -|(% style="width:171px" %)High Logic temperature|(% style="width:263px" %)At least one of the Logic devices is overheated|(% style="width:116px" %) |(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)Hi. Logic temp.|(% style="width:51px" %)HLT|(% style="width:283px" %) |(% style="width:306px" %)
100 -|(% style="width:171px" %)High temperature (CH)|(% style="width:263px" %)Temperature is too high for charging|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)High temp. CH|(% style="width:51px" %)HTC|(% style="width:283px" %) |(% style="width:306px" %)
101 -|(% style="width:171px" %)High temperature (DCH)|(% style="width:263px" %)Temperature is too high for discharging|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)High temp. DCH|(% style="width:51px" %)HTD|(% style="width:283px" %) |(% style="width:306px" %)
102 -|(% style="width:171px" %)High voltage fault|(% style="width:263px" %)Failure of high voltage measuring circuits|(% style="width:116px" %)Yes|(% style="width:34px" %) | |Yes|(% style="width:142px" %)HV fault|(% style="width:51px" %)HVF|(% style="width:283px" %) |(% style="width:306px" %)
103 -|(% style="width:171px" %)HVIL error|(% style="width:263px" %)Breakage of high-voltage interlock current loop|(% style="width:116px" %)Yes|(% style="width:34px" %) | |Yes|(% style="width:142px" %)HVIL error|(% style="width:51px" %)HE|(% style="width:283px" %) |(% style="width:306px" %)
104 -|(% style="width:171px" %)HYG offline|(% style="width:263px" %)Connection with the HYG forklift is lost|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)HYG offline|(% style="width:51px" %)HYG|(% style="width:283px" %) |(% style="width:306px" %)
105 -|(% style="width:171px" %)Insulation fault|(% style="width:263px" %)Insulation resistance is too low|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Insulation fault|(% style="width:51px" %)INF|(% style="width:283px" %) |(% style="width:306px" %)
106 -|(% style="width:171px" %)Logic count error|(% style="width:263px" %)The number of BMS Logic devices differs from the required value|(% style="width:116px" %) |(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)Logic count|(% style="width:51px" %)LOG|(% style="width:283px" %) |(% style="width:306px" %)
107 -|(% style="width:171px" %)Logic offline (Cell monitor offline)|(% style="width:263px" %)BMS Main devices: at least one of the Logic devices is offline.
108 -BMS Mini devices: connection with cell monitor is lost.|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Logic offline|(% style="width:51px" %)LOF|(% style="width:283px" %) |(% style="width:306px" %)
109 -|(% style="width:171px" %)Low temperature (CH)|(% style="width:263px" %)Temperature is too low for charging;|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Low temp. CH|(% style="width:51px" %)LTC|(% style="width:283px" %) |(% style="width:306px" %)
110 -|(% style="width:171px" %)Low temperature (DCH)|(% style="width:263px" %)Temperature is too low for discharging;|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Low temp. DCH|(% style="width:51px" %)LTD|(% style="width:283px" %) |(% style="width:306px" %)
111 -|(% style="width:171px" %)Main contactor feedback error|(% style="width:263px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:116px" %)Yes|(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)Main cont. feed.|(% style="width:51px" %)MCF|(% style="width:283px" %) |(% style="width:306px" %)
112 -|(% style="width:171px" %)Mount error|(% style="width:263px" %)SD card cannot be mounted|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Mount error|(% style="width:51px" %)MNT|(% style="width:283px" %) |(% style="width:306px" %)
113 -|(% style="width:171px" %)Need acknowledge|(% style="width:263px" %)There is an unacknowledged error in error journal|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Need ACK|(% style="width:51px" %)ACK|(% style="width:283px" %) |(% style="width:306px" %)
114 -|(% style="width:171px" %)No temperature sensors|(% style="width:263px" %)The device has no temperature sensors connected|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)No temp. sens.|(% style="width:51px" %)NTS|(% style="width:283px" %) |(% style="width:306px" %)
115 -|(% style="width:171px" %)Overcurrent|(% style="width:263px" %)The battery current is too high|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Overcurrent|(% style="width:51px" %)OC|(% style="width:283px" %) |(% style="width:306px" %)
116 -|(% style="width:171px" %)Overvoltage|(% style="width:263px" %)Voltage of any cell is too high|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Overvoltage|(% style="width:51px" %)OV|(% style="width:283px" %) |(% style="width:306px" %)
117 -|(% style="width:171px" %)PCH contactor feedback error|(% style="width:263px" %)The control signal for the precharging contactor and the contactor feedback differ|(% style="width:116px" %)Yes|(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)PCH cont. feed.|(% style="width:51px" %)PCF|(% style="width:283px" %) |(% style="width:306px" %)
118 -|(% style="width:171px" %)Power fault|(% style="width:263px" %)External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|(% style="width:116px" %)Yes|(% style="width:34px" %) | |Yes|(% style="width:142px" %)Power fault|(% style="width:51px" %)PF|(% style="width:283px" %) |(% style="width:306px" %)
119 -|(% style="width:171px" %)Power switch error|(% style="width:263px" %)Short circuit in contactor coil control circuit or power switch overheating|(% style="width:116px" %)Yes|(% style="width:34px" %) | |Yes|(% style="width:142px" %)PSW error|(% style="width:51px" %)PSE|(% style="width:283px" %) |(% style="width:306px" %)
120 -|(% style="width:171px" %)Precharge error|(% style="width:263px" %)Capacitive load pre-charge process did not end during the estimated time|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Precharge error|(% style="width:51px" %)PE|(% style="width:283px" %) |(% style="width:306px" %)
121 -|(% style="width:171px" %)Settings error|(% style="width:263px" %)Wrong checksum of the device settings|(% style="width:116px" %) |(% style="width:34px" %) |Yes| |(% style="width:142px" %)Settings err.|(% style="width:51px" %)SET|(% style="width:283px" %) |(% style="width:306px" %)
122 -|(% style="width:171px" %)Short circuit|(% style="width:263px" %)Flowing high battery currents during a long time|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Short circuit|(% style="width:51px" %)SHC|(% style="width:283px" %) |(% style="width:306px" %)
123 -|(% style="width:171px" %)Shunt error|(% style="width:263px" %)Internal error of the shunt current sensor|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Shunt error|(% style="width:51px" %)SHE|(% style="width:283px" %) |(% style="width:306px" %)
124 -|(% style="width:171px" %)Shunt offline|(% style="width:263px" %)Connection with the shunt current sensor is lost|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Shunt offline|(% style="width:51px" %)SHO|(% style="width:283px" %) |(% style="width:306px" %)
125 -|(% style="width:171px" %)Spirit offline|(% style="width:263px" %)Connection with the Spirit forklift is lost|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Spirit offline|(% style="width:51px" %)SPI|(% style="width:283px" %) |(% style="width:306px" %)
126 -|(% style="width:171px" %)Stuck contactor|(% style="width:263px" %)Some contactor got stuck|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Stuck contactor|(% style="width:51px" %)STC|(% style="width:283px" %) |(% style="width:306px" %)
127 -|(% style="width:171px" %)Temperature sensor is shorted|(% style="width:263px" %)Some temperature sensors are shorted|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Shorted temp.|(% style="width:51px" %)TSS|(% style="width:283px" %) |(% style="width:306px" %)
128 -|(% style="width:171px" %)Unallowable charging|(% style="width:263px" %)Charging the battery through the discharging contactor|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Unallowable CH|(% style="width:51px" %)UCH|(% style="width:283px" %) |(% style="width:306px" %)
129 -|(% style="width:171px" %)Undervoltage|(% style="width:263px" %)Voltage of any cell is too low|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Undervoltage|(% style="width:51px" %)UV|(% style="width:283px" %) |(% style="width:306px" %)
130 -|(% style="width:171px" %)Water|(% style="width:263px" %)There is water in the battery enclosure|(% style="width:116px" %)Yes|(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)Water|(% style="width:51px" %)WHU|(% style="width:283px" %) |(% style="width:306px" %)
131 -|(% style="width:171px" %)WDT reset|(% style="width:263px" %)Watchdog timer reset the device|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)WDT reset|(% style="width:51px" %)WDT|(% style="width:283px" %) |(% style="width:306px" %)
79 +|(% colspan="1" rowspan="2" style="width:171px" %)**Name **|(% colspan="1" rowspan="2" style="width:324px" %)**Description**|(% colspan="1" rowspan="2" style="width:61px" %)**Is a critical error?**|(% colspan="3" rowspan="1" style="width:215px" %)**Compability**|(% colspan="2" rowspan="1" style="width:180px" %)**BMS Display**|(% colspan="1" rowspan="2" style="width:265px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:306px" %)**Modbus**
80 +|=(% style="width: 92px;" %)**Mini S / Mini**|=(% style="width: 66px;" %)**Main 2.1**|=(% style="width: 56px;" %)**Main 3**|=(% colspan="1" style="width: 126px;" %)Short name|=(% style="width: 54px;" %)Abbr.
81 +|(% style="width:171px" %)ADC error|(% style="width:324px" %)Error of the ADC that measures the battery current|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)ADC error|(% style="width:54px" %)ADC|(% style="width:265px" %) |(% style="width:306px" %)
82 +|(% style="width:171px" %)Battery cover error|(% style="width:324px" %)Battery cover is open|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Battery cover|(% style="width:54px" %)BCE|(% style="width:265px" %) |(% style="width:306px" %)
83 +|(% style="width:171px" %)Cell count error|(% style="width:324px" %)Number of cells does not match the specified value|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Cell count|(% style="width:54px" %)CEL|(% style="width:265px" %) |(% style="width:306px" %)
84 +|(% style="width:171px" %)CH contactor cycles error|(% style="width:324px" %)Switching frequency of the charging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)CH cont. cycle|(% style="width:54px" %)CCC|(% style="width:265px" %) |(% style="width:306px" %)
85 +|(% style="width:171px" %)CH contactor feedback error|(% style="width:324px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)CH cont. feed.|(% style="width:54px" %)CCF|(% style="width:265px" %) |(% style="width:306px" %)
86 +|(% style="width:171px" %)CH/DCH contactor feedback error|(% style="width:324px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)C/D cont. feed.|(% style="width:54px" %)CDF|(% style="width:265px" %) |(% style="width:306px" %)
87 +|(% style="width:171px" %)Combilift offline|(% style="width:324px" %)Connection with the Combilift forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Combilift offl.|(% style="width:54px" %)COM|(% style="width:265px" %) |(% style="width:306px" %)
88 +|(% style="width:171px" %)Contactor feedback error|(% style="width:324px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %) |(% style="width:56px" %) |(% style="width:126px" %)Cont. feed. er.|(% style="width:54px" %)CFE|(% style="width:265px" %) |(% style="width:306px" %)
89 +|(% style="width:171px" %)Critical error|(% style="width:324px" %)Critical system error, the BMS is damaged|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Critical error|(% style="width:54px" %)CER|(% style="width:265px" %) |(% style="width:306px" %)
90 +|(% style="width:171px" %)Crown error|(% style="width:324px" %)Connection with the Crown forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Crown error|(% style="width:54px" %)CRO|(% style="width:265px" %) |(% style="width:306px" %)
91 +|(% style="width:171px" %)Current limit error|(% style="width:324px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)Cur. limit error|(% style="width:54px" %)CLE|(% style="width:265px" %) |(% style="width:306px" %)
92 +|(% style="width:171px" %)Current sensor error|(% style="width:324px" %)Error in the current sensor circuit|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Current sensor|(% style="width:54px" %)CSE|(% style="width:265px" %) |(% style="width:306px" %)
93 +|(% style="width:171px" %)DCH contactor cycles error|(% style="width:324px" %)Switching frequency of the discharging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)DCH cont. cycle|(% style="width:54px" %)DCC|(% style="width:265px" %) |(% style="width:306px" %)
94 +|(% style="width:171px" %)DCH contactor feedback error|(% style="width:324px" %)The control signal for the discharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)DCH cont. feed.|(% style="width:54px" %)DCF|(% style="width:265px" %) |(% style="width:306px" %)
95 +|(% style="width:171px" %)FS error|(% style="width:324px" %)SD card read/write error|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)FS error|(% style="width:54px" %)FSE|(% style="width:265px" %) |(% style="width:306px" %)
96 +|(% style="width:171px" %)General error|(% style="width:324px" %)Special configurable error depending on other errors|(% style="width:61px" %) |(% style="width:92px" %)Yes*|(% style="width:66px" %)Yes*|(% style="width:56px" %)Yes*|(% style="width:126px" %)General error|(% style="width:54px" %)GE|(% style="width:265px" %) |(% style="width:306px" %)
97 +|(% style="width:171px" %)High contactor temperature|(% style="width:324px" %)Temperature of a contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. cont. temp.|(% style="width:54px" %)HCT|(% style="width:265px" %) |(% style="width:306px" %)
98 +|(% style="width:171px" %)High humidity|(% style="width:324px" %)Increased humidity inside the battery|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High humidity|(% style="width:54px" %)HHU|(% style="width:265px" %) |(% style="width:306px" %)
99 +|(% style="width:171px" %)High Logic temperature|(% style="width:324px" %)At least one of the Logic devices is overheated|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. Logic temp.|(% style="width:54px" %)HLT|(% style="width:265px" %) |(% style="width:306px" %)
100 +|(% style="width:171px" %)High temperature (CH)|(% style="width:324px" %)Temperature is too high for charging|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High temp. CH|(% style="width:54px" %)HTC|(% style="width:265px" %) |(% style="width:306px" %)
101 +|(% style="width:171px" %)High temperature (DCH)|(% style="width:324px" %)Temperature is too high for discharging|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High temp. DCH|(% style="width:54px" %)HTD|(% style="width:265px" %) |(% style="width:306px" %)
102 +|(% style="width:171px" %)High voltage fault|(% style="width:324px" %)Failure of high voltage measuring circuits|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)HV fault|(% style="width:54px" %)HVF|(% style="width:265px" %) |(% style="width:306px" %)
103 +|(% style="width:171px" %)HVIL error|(% style="width:324px" %)Breakage of high-voltage interlock current loop|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)HVIL error|(% style="width:54px" %)HE|(% style="width:265px" %) |(% style="width:306px" %)
104 +|(% style="width:171px" %)HYG offline|(% style="width:324px" %)Connection with the HYG forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)HYG offline|(% style="width:54px" %)HYG|(% style="width:265px" %) |(% style="width:306px" %)
105 +|(% style="width:171px" %)Insulation fault|(% style="width:324px" %)Insulation resistance is too low|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Insulation fault|(% style="width:54px" %)INF|(% style="width:265px" %) |(% style="width:306px" %)
106 +|(% style="width:171px" %)Logic count error|(% style="width:324px" %)The number of BMS Logic devices differs from the required value|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic count|(% style="width:54px" %)LOG|(% style="width:265px" %) |(% style="width:306px" %)
107 +|(% style="width:171px" %)Logic offline (Cell monitor offline)|(% style="width:324px" %)BMS Main devices: at least one of the Logic devices is offline.
108 +BMS Mini devices: connection with cell monitor is lost.|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic offline|(% style="width:54px" %)LOF|(% style="width:265px" %) |(% style="width:306px" %)
109 +|(% style="width:171px" %)Low temperature (CH)|(% style="width:324px" %)Temperature is too low for charging;|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Low temp. CH|(% style="width:54px" %)LTC|(% style="width:265px" %) |(% style="width:306px" %)
110 +|(% style="width:171px" %)Low temperature (DCH)|(% style="width:324px" %)Temperature is too low for discharging;|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Low temp. DCH|(% style="width:54px" %)LTD|(% style="width:265px" %) |(% style="width:306px" %)
111 +|(% style="width:171px" %)Main contactor feedback error|(% style="width:324px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Main cont. feed.|(% style="width:54px" %)MCF|(% style="width:265px" %) |(% style="width:306px" %)
112 +|(% style="width:171px" %)Mount error|(% style="width:324px" %)SD card cannot be mounted|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Mount error|(% style="width:54px" %)MNT|(% style="width:265px" %) |(% style="width:306px" %)
113 +|(% style="width:171px" %)Need acknowledge|(% style="width:324px" %)There is an unacknowledged error in error journal|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Need ACK|(% style="width:54px" %)ACK|(% style="width:265px" %) |(% style="width:306px" %)
114 +|(% style="width:171px" %)No temperature sensors|(% style="width:324px" %)The device has no temperature sensors connected|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)No temp. sens.|(% style="width:54px" %)NTS|(% style="width:265px" %) |(% style="width:306px" %)
115 +|(% style="width:171px" %)Overcurrent|(% style="width:324px" %)The battery current is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Overcurrent|(% style="width:54px" %)OC|(% style="width:265px" %) |(% style="width:306px" %)
116 +|(% style="width:171px" %)Overvoltage|(% style="width:324px" %)Voltage of any cell is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Overvoltage|(% style="width:54px" %)OV|(% style="width:265px" %) |(% style="width:306px" %)
117 +|(% style="width:171px" %)PCH contactor feedback error|(% style="width:324px" %)The control signal for the precharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)PCH cont. feed.|(% style="width:54px" %)PCF|(% style="width:265px" %) |(% style="width:306px" %)
118 +|(% style="width:171px" %)Power fault|(% style="width:324px" %)External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)Power fault|(% style="width:54px" %)PF|(% style="width:265px" %) |(% style="width:306px" %)
119 +|(% style="width:171px" %)Power switch error|(% style="width:324px" %)Short circuit in contactor coil control circuit or power switch overheating|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)PSW error|(% style="width:54px" %)PSE|(% style="width:265px" %) |(% style="width:306px" %)
120 +|(% style="width:171px" %)Precharge error|(% style="width:324px" %)Capacitive load pre-charge process did not end during the estimated time|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Precharge error|(% style="width:54px" %)PE|(% style="width:265px" %) |(% style="width:306px" %)
121 +|(% style="width:171px" %)Settings error|(% style="width:324px" %)Wrong checksum of the device settings|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %) |(% style="width:126px" %)Settings err.|(% style="width:54px" %)SET|(% style="width:265px" %) |(% style="width:306px" %)
122 +|(% style="width:171px" %)Short circuit|(% style="width:324px" %)Flowing high battery currents during a long time|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Short circuit|(% style="width:54px" %)SHC|(% style="width:265px" %) |(% style="width:306px" %)
123 +|(% style="width:171px" %)Shunt error|(% style="width:324px" %)Internal error of the shunt current sensor|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shunt error|(% style="width:54px" %)SHE|(% style="width:265px" %) |(% style="width:306px" %)
124 +|(% style="width:171px" %)Shunt offline|(% style="width:324px" %)Connection with the shunt current sensor is lost|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shunt offline|(% style="width:54px" %)SHO|(% style="width:265px" %) |(% style="width:306px" %)
125 +|(% style="width:171px" %)Spirit offline|(% style="width:324px" %)Connection with the Spirit forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Spirit offline|(% style="width:54px" %)SPI|(% style="width:265px" %) |(% style="width:306px" %)
126 +|(% style="width:171px" %)Stuck contactor|(% style="width:324px" %)Some contactor got stuck|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Stuck contactor|(% style="width:54px" %)STC|(% style="width:265px" %) |(% style="width:306px" %)
127 +|(% style="width:171px" %)Temperature sensor is shorted|(% style="width:324px" %)Some temperature sensors are shorted|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shorted temp.|(% style="width:54px" %)TSS|(% style="width:265px" %) |(% style="width:306px" %)
128 +|(% style="width:171px" %)Unallowable charging|(% style="width:324px" %)Charging the battery through the discharging contactor|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Unallowable CH|(% style="width:54px" %)UCH|(% style="width:265px" %) |(% style="width:306px" %)
129 +|(% style="width:171px" %)Undervoltage|(% style="width:324px" %)Voltage of any cell is too low|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Undervoltage|(% style="width:54px" %)UV|(% style="width:265px" %) |(% style="width:306px" %)
130 +|(% style="width:171px" %)Water|(% style="width:324px" %)There is water in the battery enclosure|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Water|(% style="width:54px" %)WHU|(% style="width:265px" %) |(% style="width:306px" %)
131 +|(% style="width:171px" %)WDT reset|(% style="width:324px" %)Watchdog timer reset the device|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)WDT reset|(% style="width:54px" %)WDT|(% style="width:265px" %) |(% style="width:306px" %)
132 132  
133 133  ~* The signal can be assigned to discrete outputs and relays.