Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -76,58 +76,58 @@ 76 76 == Errors == 77 77 78 78 (% style="width:1533px" %) 79 -|(% colspan="1" rowspan="2" style="width:171px" %)**Name **|(% colspan="1" rowspan="2" style="width: 263px" %)**Description**|(% colspan="1" rowspan="2" style="width:116px" %)**Is a critical error?**|(% colspan="3" rowspan="1" style="width:190px" %)**Compability**|(% colspan="2" rowspan="1" style="width:193px" %)**BMS Display**|(% colspan="1" rowspan="2" style="width:283px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:306px" %)**Modbus**80 -|=(% style="width: 34px;" %)**Mini S / Mini**|=(% style="width:76px;" %)**Main 2.1**|=(% style="width:80px;" %)**Main 3**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 51px;" %)Abbr.81 -|(% style="width:171px" %)ADC error|(% style="width: 263px" %)Error of the ADC that measures the battery current|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)ADC error|(% style="width:51px" %)ADC|(% style="width:283px" %) |(% style="width:306px" %)82 -|(% style="width:171px" %)Battery cover error|(% style="width: 263px" %)Battery cover is open|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Battery cover|(% style="width:51px" %)BCE|(% style="width:283px" %) |(% style="width:306px" %)83 -|(% style="width:171px" %)Cell count error|(% style="width: 263px" %)Number of cells does not match the specified value|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Cell count|(% style="width:51px" %)CEL|(% style="width:283px" %) |(% style="width:306px" %)84 -|(% style="width:171px" %)CH contactor cycles error|(% style="width: 263px" %)Switching frequency of the charging contactor is too high|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)CH cont. cycle|(% style="width:51px" %)CCC|(% style="width:283px" %) |(% style="width:306px" %)85 -|(% style="width:171px" %)CH contactor feedback error|(% style="width: 263px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="width:116px" %)Yes|(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)CH cont. feed.|(% style="width:51px" %)CCF|(% style="width:283px" %) |(% style="width:306px" %)86 -|(% style="width:171px" %)CH/DCH contactor feedback error|(% style="width: 263px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:116px" %)Yes|(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)C/D cont. feed.|(% style="width:51px" %)CDF|(% style="width:283px" %) |(% style="width:306px" %)87 -|(% style="width:171px" %)Combilift offline|(% style="width: 263px" %)Connection with the Combilift forklift is lost|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Combilift offl.|(% style="width:51px" %)COM|(% style="width:283px" %) |(% style="width:306px" %)88 -|(% style="width:171px" %)Contactor feedback error|(% style="width: 263px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="width:116px" %) |(% style="width:34px" %)Yes| | |(% style="width:142px" %)Cont. feed. er.|(% style="width:51px" %)CFE|(% style="width:283px" %) |(% style="width:306px" %)89 -|(% style="width:171px" %)Critical error|(% style="width: 263px" %)Critical system error, the BMS is damaged|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Critical error|(% style="width:51px" %)CER|(% style="width:283px" %) |(% style="width:306px" %)90 -|(% style="width:171px" %)Crown error|(% style="width: 263px" %)Connection with the Crown forklift is lost|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Crown error|(% style="width:51px" %)CRO|(% style="width:283px" %) |(% style="width:306px" %)91 -|(% style="width:171px" %)Current limit error|(% style="width: 263px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:116px" %) |(% style="width:34px" %)Yes| |Yes|(% style="width:142px" %)Cur. limit error|(% style="width:51px" %)CLE|(% style="width:283px" %) |(% style="width:306px" %)92 -|(% style="width:171px" %)Current sensor error|(% style="width: 263px" %)Error in the current sensor circuit|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Current sensor|(% style="width:51px" %)CSE|(% style="width:283px" %) |(% style="width:306px" %)93 -|(% style="width:171px" %)DCH contactor cycles error|(% style="width: 263px" %)Switching frequency of the discharging contactor is too high|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)DCH cont. cycle|(% style="width:51px" %)DCC|(% style="width:283px" %) |(% style="width:306px" %)94 -|(% style="width:171px" %)DCH contactor feedback error|(% style="width: 263px" %)The control signal for the discharging contactor and the contactor feedback differ|(% style="width:116px" %)Yes|(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)DCH cont. feed.|(% style="width:51px" %)DCF|(% style="width:283px" %) |(% style="width:306px" %)95 -|(% style="width:171px" %)FS error|(% style="width: 263px" %)SD card read/write error|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)FS error|(% style="width:51px" %)FSE|(% style="width:283px" %) |(% style="width:306px" %)96 -|(% style="width:171px" %)General error|(% style="width: 263px" %)Special configurable error depending on other errors|(% style="width:116px" %) |(% style="width:34px" %)Yes*|Yes*|Yes*|(% style="width:142px" %)General error|(% style="width:51px" %)GE|(% style="width:283px" %) |(% style="width:306px" %)97 -|(% style="width:171px" %)High contactor temperature|(% style="width: 263px" %)Temperature of a contactor is too high|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Hi. cont. temp.|(% style="width:51px" %)HCT|(% style="width:283px" %) |(% style="width:306px" %)98 -|(% style="width:171px" %)High humidity|(% style="width: 263px" %)Increased humidity inside the battery|(% style="width:116px" %) |(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)High humidity|(% style="width:51px" %)HHU|(% style="width:283px" %) |(% style="width:306px" %)99 -|(% style="width:171px" %)High Logic temperature|(% style="width: 263px" %)At least one of the Logic devices is overheated|(% style="width:116px" %) |(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)Hi. Logic temp.|(% style="width:51px" %)HLT|(% style="width:283px" %) |(% style="width:306px" %)100 -|(% style="width:171px" %)High temperature (CH)|(% style="width: 263px" %)Temperature is too high for charging|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)High temp. CH|(% style="width:51px" %)HTC|(% style="width:283px" %) |(% style="width:306px" %)101 -|(% style="width:171px" %)High temperature (DCH)|(% style="width: 263px" %)Temperature is too high for discharging|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)High temp. DCH|(% style="width:51px" %)HTD|(% style="width:283px" %) |(% style="width:306px" %)102 -|(% style="width:171px" %)High voltage fault|(% style="width: 263px" %)Failure of high voltage measuring circuits|(% style="width:116px" %)Yes|(% style="width:34px" %) | |Yes|(% style="width:142px" %)HV fault|(% style="width:51px" %)HVF|(% style="width:283px" %) |(% style="width:306px" %)103 -|(% style="width:171px" %)HVIL error|(% style="width: 263px" %)Breakage of high-voltage interlock current loop|(% style="width:116px" %)Yes|(% style="width:34px" %) | |Yes|(% style="width:142px" %)HVIL error|(% style="width:51px" %)HE|(% style="width:283px" %) |(% style="width:306px" %)104 -|(% style="width:171px" %)HYG offline|(% style="width: 263px" %)Connection with the HYG forklift is lost|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)HYG offline|(% style="width:51px" %)HYG|(% style="width:283px" %) |(% style="width:306px" %)105 -|(% style="width:171px" %)Insulation fault|(% style="width: 263px" %)Insulation resistance is too low|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Insulation fault|(% style="width:51px" %)INF|(% style="width:283px" %) |(% style="width:306px" %)106 -|(% style="width:171px" %)Logic count error|(% style="width: 263px" %)The number of BMS Logic devices differs from the required value|(% style="width:116px" %) |(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)Logic count|(% style="width:51px" %)LOG|(% style="width:283px" %) |(% style="width:306px" %)107 -|(% style="width:171px" %)Logic offline (Cell monitor offline)|(% style="width: 263px" %)BMS Main devices: at least one of the Logic devices is offline.108 -BMS Mini devices: connection with cell monitor is lost.|(% style="width: 116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Logic offline|(% style="width:51px" %)LOF|(% style="width:283px" %) |(% style="width:306px" %)109 -|(% style="width:171px" %)Low temperature (CH)|(% style="width: 263px" %)Temperature is too low for charging;|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Low temp. CH|(% style="width:51px" %)LTC|(% style="width:283px" %) |(% style="width:306px" %)110 -|(% style="width:171px" %)Low temperature (DCH)|(% style="width: 263px" %)Temperature is too low for discharging;|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Low temp. DCH|(% style="width:51px" %)LTD|(% style="width:283px" %) |(% style="width:306px" %)111 -|(% style="width:171px" %)Main contactor feedback error|(% style="width: 263px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:116px" %)Yes|(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)Main cont. feed.|(% style="width:51px" %)MCF|(% style="width:283px" %) |(% style="width:306px" %)112 -|(% style="width:171px" %)Mount error|(% style="width: 263px" %)SD card cannot be mounted|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Mount error|(% style="width:51px" %)MNT|(% style="width:283px" %) |(% style="width:306px" %)113 -|(% style="width:171px" %)Need acknowledge|(% style="width: 263px" %)There is an unacknowledged error in error journal|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Need ACK|(% style="width:51px" %)ACK|(% style="width:283px" %) |(% style="width:306px" %)114 -|(% style="width:171px" %)No temperature sensors|(% style="width: 263px" %)The device has no temperature sensors connected|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)No temp. sens.|(% style="width:51px" %)NTS|(% style="width:283px" %) |(% style="width:306px" %)115 -|(% style="width:171px" %)Overcurrent|(% style="width: 263px" %)The battery current is too high|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Overcurrent|(% style="width:51px" %)OC|(% style="width:283px" %) |(% style="width:306px" %)116 -|(% style="width:171px" %)Overvoltage|(% style="width: 263px" %)Voltage of any cell is too high|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Overvoltage|(% style="width:51px" %)OV|(% style="width:283px" %) |(% style="width:306px" %)117 -|(% style="width:171px" %)PCH contactor feedback error|(% style="width: 263px" %)The control signal for the precharging contactor and the contactor feedback differ|(% style="width:116px" %)Yes|(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)PCH cont. feed.|(% style="width:51px" %)PCF|(% style="width:283px" %) |(% style="width:306px" %)118 -|(% style="width:171px" %)Power fault|(% style="width: 263px" %)External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|(% style="width:116px" %)Yes|(% style="width:34px" %) | |Yes|(% style="width:142px" %)Power fault|(% style="width:51px" %)PF|(% style="width:283px" %) |(% style="width:306px" %)119 -|(% style="width:171px" %)Power switch error|(% style="width: 263px" %)Short circuit in contactor coil control circuit or power switch overheating|(% style="width:116px" %)Yes|(% style="width:34px" %) | |Yes|(% style="width:142px" %)PSW error|(% style="width:51px" %)PSE|(% style="width:283px" %) |(% style="width:306px" %)120 -|(% style="width:171px" %)Precharge error|(% style="width: 263px" %)Capacitive load pre-charge process did not end during the estimated time|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Precharge error|(% style="width:51px" %)PE|(% style="width:283px" %) |(% style="width:306px" %)121 -|(% style="width:171px" %)Settings error|(% style="width: 263px" %)Wrong checksum of the device settings|(% style="width:116px" %) |(% style="width:34px" %) |Yes| |(% style="width:142px" %)Settings err.|(% style="width:51px" %)SET|(% style="width:283px" %) |(% style="width:306px" %)122 -|(% style="width:171px" %)Short circuit|(% style="width: 263px" %)Flowing high battery currents during a long time|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Short circuit|(% style="width:51px" %)SHC|(% style="width:283px" %) |(% style="width:306px" %)123 -|(% style="width:171px" %)Shunt error|(% style="width: 263px" %)Internal error of the shunt current sensor|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Shunt error|(% style="width:51px" %)SHE|(% style="width:283px" %) |(% style="width:306px" %)124 -|(% style="width:171px" %)Shunt offline|(% style="width: 263px" %)Connection with the shunt current sensor is lost|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Shunt offline|(% style="width:51px" %)SHO|(% style="width:283px" %) |(% style="width:306px" %)125 -|(% style="width:171px" %)Spirit offline|(% style="width: 263px" %)Connection with the Spirit forklift is lost|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Spirit offline|(% style="width:51px" %)SPI|(% style="width:283px" %) |(% style="width:306px" %)126 -|(% style="width:171px" %)Stuck contactor|(% style="width: 263px" %)Some contactor got stuck|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Stuck contactor|(% style="width:51px" %)STC|(% style="width:283px" %) |(% style="width:306px" %)127 -|(% style="width:171px" %)Temperature sensor is shorted|(% style="width: 263px" %)Some temperature sensors are shorted|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Shorted temp.|(% style="width:51px" %)TSS|(% style="width:283px" %) |(% style="width:306px" %)128 -|(% style="width:171px" %)Unallowable charging|(% style="width: 263px" %)Charging the battery through the discharging contactor|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Unallowable CH|(% style="width:51px" %)UCH|(% style="width:283px" %) |(% style="width:306px" %)129 -|(% style="width:171px" %)Undervoltage|(% style="width: 263px" %)Voltage of any cell is too low|(% style="width:116px" %) |(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)Undervoltage|(% style="width:51px" %)UV|(% style="width:283px" %) |(% style="width:306px" %)130 -|(% style="width:171px" %)Water|(% style="width: 263px" %)There is water in the battery enclosure|(% style="width:116px" %)Yes|(% style="width:34px" %) |Yes|Yes|(% style="width:142px" %)Water|(% style="width:51px" %)WHU|(% style="width:283px" %) |(% style="width:306px" %)131 -|(% style="width:171px" %)WDT reset|(% style="width: 263px" %)Watchdog timer reset the device|(% style="width:116px" %)Yes|(% style="width:34px" %)Yes|Yes|Yes|(% style="width:142px" %)WDT reset|(% style="width:51px" %)WDT|(% style="width:283px" %) |(% style="width:306px" %)79 +|(% colspan="1" rowspan="2" style="width:171px" %)**Name **|(% colspan="1" rowspan="2" style="width:324px" %)**Description**|(% colspan="1" rowspan="2" style="width:61px" %)**Is a critical error?**|(% colspan="3" rowspan="1" style="width:215px" %)**Compability**|(% colspan="2" rowspan="1" style="width:180px" %)**BMS Display**|(% colspan="1" rowspan="2" style="width:265px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:306px" %)**Modbus** 80 +|=(% style="width: 92px;" %)**Mini S / Mini**|=(% style="width: 66px;" %)**Main 2.1**|=(% style="width: 56px;" %)**Main 3**|=(% colspan="1" style="width: 126px;" %)Short name|=(% style="width: 54px;" %)Abbr. 81 +|(% style="width:171px" %)ADC error|(% style="width:324px" %)Error of the ADC that measures the battery current|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)ADC error|(% style="width:54px" %)ADC|(% style="width:265px" %) |(% style="width:306px" %) 82 +|(% style="width:171px" %)Battery cover error|(% style="width:324px" %)Battery cover is open|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Battery cover|(% style="width:54px" %)BCE|(% style="width:265px" %) |(% style="width:306px" %) 83 +|(% style="width:171px" %)Cell count error|(% style="width:324px" %)Number of cells does not match the specified value|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Cell count|(% style="width:54px" %)CEL|(% style="width:265px" %) |(% style="width:306px" %) 84 +|(% style="width:171px" %)CH contactor cycles error|(% style="width:324px" %)Switching frequency of the charging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)CH cont. cycle|(% style="width:54px" %)CCC|(% style="width:265px" %) |(% style="width:306px" %) 85 +|(% style="width:171px" %)CH contactor feedback error|(% style="width:324px" %)The control signal for the charging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)CH cont. feed.|(% style="width:54px" %)CCF|(% style="width:265px" %) |(% style="width:306px" %) 86 +|(% style="width:171px" %)CH/DCH contactor feedback error|(% style="width:324px" %)The control signal for the charging/discharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)C/D cont. feed.|(% style="width:54px" %)CDF|(% style="width:265px" %) |(% style="width:306px" %) 87 +|(% style="width:171px" %)Combilift offline|(% style="width:324px" %)Connection with the Combilift forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Combilift offl.|(% style="width:54px" %)COM|(% style="width:265px" %) |(% style="width:306px" %) 88 +|(% style="width:171px" %)Contactor feedback error|(% style="width:324px" %)Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %) |(% style="width:56px" %) |(% style="width:126px" %)Cont. feed. er.|(% style="width:54px" %)CFE|(% style="width:265px" %) |(% style="width:306px" %) 89 +|(% style="width:171px" %)Critical error|(% style="width:324px" %)Critical system error, the BMS is damaged|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Critical error|(% style="width:54px" %)CER|(% style="width:265px" %) |(% style="width:306px" %) 90 +|(% style="width:171px" %)Crown error|(% style="width:324px" %)Connection with the Crown forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Crown error|(% style="width:54px" %)CRO|(% style="width:265px" %) |(% style="width:306px" %) 91 +|(% style="width:171px" %)Current limit error|(% style="width:324px" %)Charging or discharging current is more than the limit calculated by Charge map or Discharge map|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)Cur. limit error|(% style="width:54px" %)CLE|(% style="width:265px" %) |(% style="width:306px" %) 92 +|(% style="width:171px" %)Current sensor error|(% style="width:324px" %)Error in the current sensor circuit|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Current sensor|(% style="width:54px" %)CSE|(% style="width:265px" %) |(% style="width:306px" %) 93 +|(% style="width:171px" %)DCH contactor cycles error|(% style="width:324px" %)Switching frequency of the discharging contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)DCH cont. cycle|(% style="width:54px" %)DCC|(% style="width:265px" %) |(% style="width:306px" %) 94 +|(% style="width:171px" %)DCH contactor feedback error|(% style="width:324px" %)The control signal for the discharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)DCH cont. feed.|(% style="width:54px" %)DCF|(% style="width:265px" %) |(% style="width:306px" %) 95 +|(% style="width:171px" %)FS error|(% style="width:324px" %)SD card read/write error|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)FS error|(% style="width:54px" %)FSE|(% style="width:265px" %) |(% style="width:306px" %) 96 +|(% style="width:171px" %)General error|(% style="width:324px" %)Special configurable error depending on other errors|(% style="width:61px" %) |(% style="width:92px" %)Yes*|(% style="width:66px" %)Yes*|(% style="width:56px" %)Yes*|(% style="width:126px" %)General error|(% style="width:54px" %)GE|(% style="width:265px" %) |(% style="width:306px" %) 97 +|(% style="width:171px" %)High contactor temperature|(% style="width:324px" %)Temperature of a contactor is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. cont. temp.|(% style="width:54px" %)HCT|(% style="width:265px" %) |(% style="width:306px" %) 98 +|(% style="width:171px" %)High humidity|(% style="width:324px" %)Increased humidity inside the battery|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High humidity|(% style="width:54px" %)HHU|(% style="width:265px" %) |(% style="width:306px" %) 99 +|(% style="width:171px" %)High Logic temperature|(% style="width:324px" %)At least one of the Logic devices is overheated|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Hi. Logic temp.|(% style="width:54px" %)HLT|(% style="width:265px" %) |(% style="width:306px" %) 100 +|(% style="width:171px" %)High temperature (CH)|(% style="width:324px" %)Temperature is too high for charging|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High temp. CH|(% style="width:54px" %)HTC|(% style="width:265px" %) |(% style="width:306px" %) 101 +|(% style="width:171px" %)High temperature (DCH)|(% style="width:324px" %)Temperature is too high for discharging|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)High temp. DCH|(% style="width:54px" %)HTD|(% style="width:265px" %) |(% style="width:306px" %) 102 +|(% style="width:171px" %)High voltage fault|(% style="width:324px" %)Failure of high voltage measuring circuits|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)HV fault|(% style="width:54px" %)HVF|(% style="width:265px" %) |(% style="width:306px" %) 103 +|(% style="width:171px" %)HVIL error|(% style="width:324px" %)Breakage of high-voltage interlock current loop|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)HVIL error|(% style="width:54px" %)HE|(% style="width:265px" %) |(% style="width:306px" %) 104 +|(% style="width:171px" %)HYG offline|(% style="width:324px" %)Connection with the HYG forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)HYG offline|(% style="width:54px" %)HYG|(% style="width:265px" %) |(% style="width:306px" %) 105 +|(% style="width:171px" %)Insulation fault|(% style="width:324px" %)Insulation resistance is too low|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Insulation fault|(% style="width:54px" %)INF|(% style="width:265px" %) |(% style="width:306px" %) 106 +|(% style="width:171px" %)Logic count error|(% style="width:324px" %)The number of BMS Logic devices differs from the required value|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic count|(% style="width:54px" %)LOG|(% style="width:265px" %) |(% style="width:306px" %) 107 +|(% style="width:171px" %)Logic offline (Cell monitor offline)|(% style="width:324px" %)BMS Main devices: at least one of the Logic devices is offline. 108 +BMS Mini devices: connection with cell monitor is lost.|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Logic offline|(% style="width:54px" %)LOF|(% style="width:265px" %) |(% style="width:306px" %) 109 +|(% style="width:171px" %)Low temperature (CH)|(% style="width:324px" %)Temperature is too low for charging;|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Low temp. CH|(% style="width:54px" %)LTC|(% style="width:265px" %) |(% style="width:306px" %) 110 +|(% style="width:171px" %)Low temperature (DCH)|(% style="width:324px" %)Temperature is too low for discharging;|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Low temp. DCH|(% style="width:54px" %)LTD|(% style="width:265px" %) |(% style="width:306px" %) 111 +|(% style="width:171px" %)Main contactor feedback error|(% style="width:324px" %)The control signal for the main contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Main cont. feed.|(% style="width:54px" %)MCF|(% style="width:265px" %) |(% style="width:306px" %) 112 +|(% style="width:171px" %)Mount error|(% style="width:324px" %)SD card cannot be mounted|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Mount error|(% style="width:54px" %)MNT|(% style="width:265px" %) |(% style="width:306px" %) 113 +|(% style="width:171px" %)Need acknowledge|(% style="width:324px" %)There is an unacknowledged error in error journal|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Need ACK|(% style="width:54px" %)ACK|(% style="width:265px" %) |(% style="width:306px" %) 114 +|(% style="width:171px" %)No temperature sensors|(% style="width:324px" %)The device has no temperature sensors connected|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)No temp. sens.|(% style="width:54px" %)NTS|(% style="width:265px" %) |(% style="width:306px" %) 115 +|(% style="width:171px" %)Overcurrent|(% style="width:324px" %)The battery current is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Overcurrent|(% style="width:54px" %)OC|(% style="width:265px" %) |(% style="width:306px" %) 116 +|(% style="width:171px" %)Overvoltage|(% style="width:324px" %)Voltage of any cell is too high|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Overvoltage|(% style="width:54px" %)OV|(% style="width:265px" %) |(% style="width:306px" %) 117 +|(% style="width:171px" %)PCH contactor feedback error|(% style="width:324px" %)The control signal for the precharging contactor and the contactor feedback differ|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)PCH cont. feed.|(% style="width:54px" %)PCF|(% style="width:265px" %) |(% style="width:306px" %) 118 +|(% style="width:171px" %)Power fault|(% style="width:324px" %)External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)Power fault|(% style="width:54px" %)PF|(% style="width:265px" %) |(% style="width:306px" %) 119 +|(% style="width:171px" %)Power switch error|(% style="width:324px" %)Short circuit in contactor coil control circuit or power switch overheating|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %) |(% style="width:56px" %)Yes|(% style="width:126px" %)PSW error|(% style="width:54px" %)PSE|(% style="width:265px" %) |(% style="width:306px" %) 120 +|(% style="width:171px" %)Precharge error|(% style="width:324px" %)Capacitive load pre-charge process did not end during the estimated time|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Precharge error|(% style="width:54px" %)PE|(% style="width:265px" %) |(% style="width:306px" %) 121 +|(% style="width:171px" %)Settings error|(% style="width:324px" %)Wrong checksum of the device settings|(% style="width:61px" %) |(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %) |(% style="width:126px" %)Settings err.|(% style="width:54px" %)SET|(% style="width:265px" %) |(% style="width:306px" %) 122 +|(% style="width:171px" %)Short circuit|(% style="width:324px" %)Flowing high battery currents during a long time|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Short circuit|(% style="width:54px" %)SHC|(% style="width:265px" %) |(% style="width:306px" %) 123 +|(% style="width:171px" %)Shunt error|(% style="width:324px" %)Internal error of the shunt current sensor|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shunt error|(% style="width:54px" %)SHE|(% style="width:265px" %) |(% style="width:306px" %) 124 +|(% style="width:171px" %)Shunt offline|(% style="width:324px" %)Connection with the shunt current sensor is lost|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shunt offline|(% style="width:54px" %)SHO|(% style="width:265px" %) |(% style="width:306px" %) 125 +|(% style="width:171px" %)Spirit offline|(% style="width:324px" %)Connection with the Spirit forklift is lost|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Spirit offline|(% style="width:54px" %)SPI|(% style="width:265px" %) |(% style="width:306px" %) 126 +|(% style="width:171px" %)Stuck contactor|(% style="width:324px" %)Some contactor got stuck|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Stuck contactor|(% style="width:54px" %)STC|(% style="width:265px" %) |(% style="width:306px" %) 127 +|(% style="width:171px" %)Temperature sensor is shorted|(% style="width:324px" %)Some temperature sensors are shorted|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Shorted temp.|(% style="width:54px" %)TSS|(% style="width:265px" %) |(% style="width:306px" %) 128 +|(% style="width:171px" %)Unallowable charging|(% style="width:324px" %)Charging the battery through the discharging contactor|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Unallowable CH|(% style="width:54px" %)UCH|(% style="width:265px" %) |(% style="width:306px" %) 129 +|(% style="width:171px" %)Undervoltage|(% style="width:324px" %)Voltage of any cell is too low|(% style="width:61px" %) |(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Undervoltage|(% style="width:54px" %)UV|(% style="width:265px" %) |(% style="width:306px" %) 130 +|(% style="width:171px" %)Water|(% style="width:324px" %)There is water in the battery enclosure|(% style="width:61px" %)Yes|(% style="width:92px" %) |(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)Water|(% style="width:54px" %)WHU|(% style="width:265px" %) |(% style="width:306px" %) 131 +|(% style="width:171px" %)WDT reset|(% style="width:324px" %)Watchdog timer reset the device|(% style="width:61px" %)Yes|(% style="width:92px" %)Yes|(% style="width:66px" %)Yes|(% style="width:56px" %)Yes|(% style="width:126px" %)WDT reset|(% style="width:54px" %)WDT|(% style="width:265px" %) |(% style="width:306px" %) 132 132 133 133 ~* The signal can be assigned to discrete outputs and relays.