Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,7 +9,7 @@ 9 9 |=(% colspan="1" rowspan="2" style="width: 198px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 399px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 223px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 216px;" %)BMS DIsplay|=(% colspan="1" rowspan="2" style="width: 236px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 268px;" %)**Modbus** 10 10 |=(% style="width: 94px;" %)**Mini S / Mini**|=(% style="width: 69px;" %)**Main 2.1**|=(% style="width: 59px;" %)**Main 3**|=(% colspan="1" style="width: 123px;" %)Short name|=(% style="width: 93px;" %)Abbreviation 11 11 |Balancing request|(% style="width:399px" %)Request to balance the cells|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Balancing req.|(% style="width:93px" %)BR|(% style="width:236px" %) |(% style="width:268px" %) 12 -|Battery cover|(% style="width:399px" %)Signal from the battery cover|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Battery cover|(% style="width:93px" %)CVR|(% style="width:236px" %) |(% style="width:268px" %)0x1022-0x1023, bit 0. Off =0, On = 1 12 +|Battery cover|(% style="width:399px" %)Signal from the battery cover|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Battery cover|(% style="width:93px" %)CVR|(% style="width:236px" %) |(% style="width:268px" %)0x1022-0x1023, bit 0. Off =0, On = 1. 13 13 |CH contactor feedback|(% style="width:399px" %)Signal from the charging contactor feedback loop|(% style="width:94px" %)Yes*|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)CH cont. feed.|(% style="width:93px" %)CCF|(% style="width:236px" %) |(% style="width:268px" %) 14 14 |CH/DCH contactor feedback|(% style="width:399px" %)Signal from the charging/discharging contactor feedback loop|(% style="width:94px" %)Yes*|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)C/D cont. feed.|(% style="width:93px" %)CDF|(% style="width:236px" %) |(% style="width:268px" %) 15 15 |Charge request|(% style="width:399px" %)Request to close the charging contactor|(% style="width:94px" %)Yes|(% style="width:69px" %)Yes|(% style="width:59px" %)Yes|(% style="width:123px" %)Charge request|(% style="width:93px" %)CRE|(% style="width:236px" %) |(% style="width:268px" %) ... ... @@ -36,7 +36,7 @@ 36 36 37 37 == Internal signals == 38 38 39 -Below is the list of internal BMS signals. Most signals can be assigned to discrete outputs and relays. 39 +Below is the list of internal BMS signals. Most signals can be assigned to discrete outputs and/or relays. 40 40 41 41 (% style="width:1277px" %) 42 42 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 140px;" %)BMS Display|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** ... ... @@ -45,11 +45,11 @@ 45 45 |Balancing 1|Command to balance the first series of cells| |Yes|Yes|(% style="width:140px" %)Balancing 1|BA1|(% style="width:140px" %) |(% style="width:142px" %) 46 46 |Balancing 2|Command to balance the second series of cells| |Yes|Yes|(% style="width:140px" %)Balancing 2|BA2|(% style="width:140px" %) |(% style="width:142px" %) 47 47 |Cell analysis|Signal indicating cell analysis process|Yes*|Yes*|Yes*|(% style="width:140px" %)Cell analysis|CEA|(% style="width:140px" %) |(% style="width:142px" %) 48 -|Charging current present|Signal showing the presence of the charging current|Yes|Yes ~*~*|Yes|(% style="width:140px" %)CH curr. present|CCP|(% style="width:140px" %) |(% style="width:142px" %)49 -|Charging|Command to control the charging contactor|Yes|Yes *|Yes|(% style="width:140px" %)Charging|CH|(% style="width:140px" %) |(% style="width:142px" %)50 -|Charging/Discharging|Command to control the charging/discharging contactor|Yes|Yes *|Yes|(% style="width:140px" %)Charg./Discharg.|C/D|(% style="width:140px" %) |(% style="width:142px" %)48 +|Charging current present|Signal showing the presence of the charging current|Yes|Yes*|Yes|(% style="width:140px" %)CH curr. present|CCP|(% style="width:140px" %) |(% style="width:142px" %) 49 +|Charging|Command to control the charging contactor|Yes|Yes|Yes|(% style="width:140px" %)Charging|CH|(% style="width:140px" %) |(% style="width:142px" %) 50 +|Charging/Discharging|Command to control the charging/discharging contactor|Yes|Yes|Yes|(% style="width:140px" %)Charg./Discharg.|C/D|(% style="width:140px" %) |(% style="width:142px" %) 51 51 |Cooler|Command to control the cooler|Yes|Yes|Yes|(% style="width:140px" %)Cooler|COO|(% style="width:140px" %) |(% style="width:142px" %) 52 -|Crown EWS| |Yes ~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Crown EWS|EWS|(% style="width:140px" %) |(% style="width:142px" %)52 +|Crown EWS| |Yes*|Yes*|Yes*|(% style="width:140px" %)Crown EWS|EWS|(% style="width:140px" %) |(% style="width:142px" %) 53 53 |Discharging (AUX)|Command to control the auxiliary discharging contactor|Yes|Yes|Yes|(% style="width:140px" %)Disch. AUX|AUX|(% style="width:140px" %) |(% style="width:142px" %) 54 54 |Discharging current present|Signal showing the presence of the discharging current|Yes|Yes*|Yes|(% style="width:140px" %)DCH cur. present|DCP|(% style="width:140px" %) |(% style="width:142px" %) 55 55 |Discharging|Command to control the discharging contactor|Yes|Yes|Yes|(% style="width:140px" %)Discharging|DCH|(% style="width:140px" %) |(% style="width:142px" %) ... ... @@ -59,7 +59,7 @@ 59 59 |High charging current|Signal indicating that the charging current is high|Yes|Yes|Yes|(% style="width:140px" %)High ch. curr.|HCC|(% style="width:140px" %) |(% style="width:142px" %) 60 60 |Init|Signal showing that the device is in the initialization phase|Yes*|Yes*|Yes*|(% style="width:140px" %)Init|INI|(% style="width:140px" %) |(% style="width:142px" %) 61 61 |Low SOC|Signal indicatiing that the battery has low SOC|Yes|Yes|Yes|(% style="width:140px" %)Low SOC|LOS|(% style="width:140px" %) |(% style="width:142px" %) 62 -|Main contactor|Command to control the main contactor|Yes|Yes *|Yes|(% style="width:140px" %)Main contactor|MCO|(% style="width:140px" %) |(% style="width:142px" %)62 +|Main contactor|Command to control the main contactor|Yes|Yes|Yes|(% style="width:140px" %)Main contactor|MCO|(% style="width:140px" %) |(% style="width:142px" %) 63 63 |Power down ACK|Command that acknowledges the BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on the power down request|Yes|Yes|Yes|(% style="width:140px" %)Power down ACK|PDA|(% style="width:140px" %) |(% style="width:142px" %) 64 64 |Power up|Signal indicating the BMS power status|Yes|Yes|Yes|(% style="width:140px" %)Power up|PUP|(% style="width:140px" %) |(% style="width:142px" %) 65 65 |Precharging|Command to control the precharging contactor|Yes|Yes|Yes|(% style="width:140px" %)Precharging|PCH|(% style="width:140px" %) |(% style="width:142px" %)