Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - Battery controllers: signals, states and errors1 +Signals, states and errors - Content
-
... ... @@ -11,7 +11,7 @@ 11 11 |Balancing request|(% style="width:500px" %)Request to balance the cells|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Balancing req.|BR|(% style="width:137px" %) |(% style="width:137px" %) 12 12 |Battery cover|(% style="width:500px" %)Signal from the battery cover|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Battery cover|CVR|(% style="width:137px" %) |(% style="width:137px" %) 13 13 |CH contactor feedback|(% style="width:500px" %)Signal from the charging contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)CH cont. feed.|CCF|(% style="width:137px" %) |(% style="width:137px" %) 14 -|CH/DCH contactor feedback|(% style="width:500px" %)Signal from the charging/discharging contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %) C/D cont. feed.|CDF|(% style="width:137px" %) |(% style="width:137px" %)14 +|CH/DCH contactor feedback|(% style="width:500px" %)Signal from the charging/discharging contactor feedback loop|(% style="width:92px" %)Yes*|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)DCH cont. feed.|DCF|(% style="width:137px" %) |(% style="width:137px" %) 15 15 |Charge request|(% style="width:500px" %)Request to close the charging contactor|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Charge request|CRE|(% style="width:137px" %) |(% style="width:137px" %) 16 16 |Charger connected|(% style="width:500px" %)Signal indicating that the charger is connected|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Charger connect.|CON|(% style="width:137px" %) |(% style="width:137px" %) 17 17 |Circuit breaker status|(% style="width:500px" %)Status of protective disconnector|(% style="width:92px" %)Yes|(% style="width:73px" %)Yes|(% style="width:78px" %)Yes|(% style="width:137px" %)Circuit breaker|CBS|(% style="width:137px" %) |(% style="width:137px" %) ... ... @@ -36,7 +36,7 @@ 36 36 37 37 == Internal signals == 38 38 39 -Below is the list of internal BMS signals. Mostsignals can be assigned to discrete outputs and relays.39 +Below is the list of internal BMS signals. The signals marked with bold text can be assigned to discrete outputs and relays. 40 40 41 41 (% style="width:1277px" %) 42 42 |=(% colspan="1" rowspan="2" style="width: 201px;" %)**Name**|=(% colspan="1" rowspan="2" style="width: 531px;" %)**Description**|=(% colspan="3" rowspan="1" style="width: 255px;" %)**Compability**|=(% colspan="2" rowspan="1" style="width: 140px;" %)BMS Display|=(% colspan="1" rowspan="2" style="width: 140px;" %)**CANopen SDO**|=(% colspan="1" rowspan="2" style="width: 142px;" %)**Modbus** ... ... @@ -51,7 +51,7 @@ 51 51 |Cooler|Command to control the cooler|Yes|Yes|Yes|(% style="width:140px" %)Cooler|COO|(% style="width:140px" %) |(% style="width:142px" %) 52 52 |Crown EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Crown EWS|EWS|(% style="width:140px" %) |(% style="width:142px" %) 53 53 |Discharging (AUX)|Command to control the auxiliary discharging contactor|Yes|Yes|Yes|(% style="width:140px" %)Disch. AUX|AUX|(% style="width:140px" %) |(% style="width:142px" %) 54 -|Discharging current present|Signal showing the presence of the discharging current|Yes|Yes~*~*|Yes|(% style="width:140px" %)DCH cur. pres ent|DCP|(% style="width:140px" %) |(% style="width:142px" %)54 +|Discharging current present|Signal showing the presence of the discharging current|Yes|Yes~*~*|Yes|(% style="width:140px" %)DCH curr. pres.|DCP|(% style="width:140px" %) |(% style="width:142px" %) 55 55 |Discharging|Command to control the discharging contactor|Yes|Yes*|Yes|(% style="width:140px" %)Discharging|DCH|(% style="width:140px" %) |(% style="width:142px" %) 56 56 |External 1|Command to control an external scheme|Yes|Yes|Yes|(% style="width:140px" %)External 1|EX1|(% style="width:140px" %) |(% style="width:142px" %) 57 57 |Heater (AUX)|Command to control the auxiliary heater| |Yes| |(% style="width:140px" %)Heater (AUX)|HAU|(% style="width:140px" %) |(% style="width:142px" %) ... ... @@ -65,9 +65,9 @@ 65 65 |Precharging|Command to control the precharging contactor|Yes|Yes|Yes|(% style="width:140px" %)Precharging|PCH|(% style="width:140px" %) |(% style="width:142px" %) 66 66 |Ready to charge|Signal showing that the battery is ready for charging|Yes|Yes|Yes|(% style="width:140px" %)Ready to charge|RTC|(% style="width:140px" %) |(% style="width:142px" %) 67 67 |Ready to discharge|Signal showing that the battery is ready for discharging|Yes|Yes|Yes|(% style="width:140px" %)Ready to disch.|RTD|(% style="width:140px" %) |(% style="width:142px" %) 68 -|Service reset|Command to restart the device|Yes*| Yes|Yes*|(% style="width:140px" %)Service reset|SR|(% style="width:140px" %) |(% style="width:142px" %)69 -|Shutdown request (Combilift)|Command to open the dischrging contactor from the Combilift truck|Yes*|Yes*|Yes*|(% style="width:140px" %)Combilift shutd.|CSH|(% style="width:140px" %) |(% style="width:142px" %) 70 -|Shutdown request (HYG/Spirit)|Command to open the dischrging contactor from the HYG truck|Yes*|Yes~*~**|Yes~*~**|(% style="width:140px" %)HYG shutdown|HSH|(% style="width:140px" %) |(% style="width:142px" %) 68 +|Service reset|Command to restart the device|Yes~*~**| |Yes~*~**|(% style="width:140px" %)Service reset|SR|(% style="width:140px" %) |(% style="width:142px" %) 69 +|Shutdown request (Combilift)|Command to open the dischrging contactor from the Combilift truck|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Combilift shutd.|CSH|(% style="width:140px" %) |(% style="width:142px" %) 70 +|Shutdown request (HYG/Spirit)|Command to open the dischrging contactor from the HYG truck|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)HYG shutdown|HSH|(% style="width:140px" %) |(% style="width:142px" %) 71 71 |Voltage too high for charging|Signal indicating that the battery is fully charged|Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Volt. too high|VTH|(% style="width:140px" %) |(% style="width:142px" %) 72 72 73 73 (% class="wikigeneratedid" %)