Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -51,34 +51,28 @@ 51 51 |Cooler|Command to control the cooler|Yes|Yes|Yes|(% style="width:140px" %)Cooler|COO|(% style="width:140px" %) |(% style="width:142px" %) 52 52 |Crown EWS| |Yes~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Crown EWS|EWS|(% style="width:140px" %) |(% style="width:142px" %) 53 53 |Discharging (AUX)|Command to control the auxiliary discharging contactor|Yes|Yes|Yes|(% style="width:140px" %)Disch. AUX|AUX|(% style="width:140px" %) |(% style="width:142px" %) 54 -|Discharging current present|Signal showing the presence of the discharging current|Yes|Yes ~*~*|Yes|(% style="width:140px" %)DCH cur. present|DCP|(% style="width:140px" %) |(% style="width:142px" %)55 -|Discharging|Command to control the discharging contactor|Yes|Yes *|Yes|(% style="width:140px" %)Discharging|DCH|(% style="width:140px" %) |(% style="width:142px" %)54 +|Discharging current present|Signal showing the presence of the discharging current|Yes|Yes*|Yes*|(% style="width:140px" %)DCH cur. present|DCP|(% style="width:140px" %) |(% style="width:142px" %) 55 +|Discharging|Command to control the discharging contactor|Yes|Yes|Yes|(% style="width:140px" %)Discharging|DCH|(% style="width:140px" %) |(% style="width:142px" %) 56 56 |External 1|Command to control an external scheme|Yes|Yes|Yes|(% style="width:140px" %)External 1|EX1|(% style="width:140px" %) |(% style="width:142px" %) 57 57 |Heater (AUX)|Command to control the auxiliary heater| |Yes| |(% style="width:140px" %)Heater (AUX)|HAU|(% style="width:140px" %) |(% style="width:142px" %) 58 58 |Heater|Command to control the heater|Yes|Yes|Yes|(% style="width:140px" %)Heater|HEA|(% style="width:140px" %) |(% style="width:142px" %) 59 -|High charging current|Signal indicating that the charging current is high|Yes|Yes ~*~*|Yes|(% style="width:140px" %)High ch. curr.|HCC|(% style="width:140px" %) |(% style="width:142px" %)60 -|Init|Signal showing that the device is in the initialization phase|Yes ~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Init|INI|(% style="width:140px" %) |(% style="width:142px" %)59 +|High charging current|Signal indicating that the charging current is high|Yes|Yes|Yes|(% style="width:140px" %)High ch. curr.|HCC|(% style="width:140px" %) |(% style="width:142px" %) 60 +|Init|Signal showing that the device is in the initialization phase|Yes*|Yes*|Yes*|(% style="width:140px" %)Init|INI|(% style="width:140px" %) |(% style="width:142px" %) 61 61 |Low SOC|Signal indicatiing that the battery has low SOC|Yes|Yes|Yes|(% style="width:140px" %)Low SOC|LOS|(% style="width:140px" %) |(% style="width:142px" %) 62 62 |Main contactor|Command to control the main contactor|Yes|Yes*|Yes|(% style="width:140px" %)Main contactor|MCO|(% style="width:140px" %) |(% style="width:142px" %) 63 -|Power down ACK|Command that acknowledges the BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on the power down request|Yes|Yes ~*~*|Yes|(% style="width:140px" %)Power down ACK|PDA|(% style="width:140px" %) |(% style="width:142px" %)63 +|Power down ACK|Command that acknowledges the BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on the power down request|Yes|Yes|Yes|(% style="width:140px" %)Power down ACK|PDA|(% style="width:140px" %) |(% style="width:142px" %) 64 64 |Power up|Signal indicating the BMS power status|Yes|Yes|Yes|(% style="width:140px" %)Power up|PUP|(% style="width:140px" %) |(% style="width:142px" %) 65 65 |Precharging|Command to control the precharging contactor|Yes|Yes|Yes|(% style="width:140px" %)Precharging|PCH|(% style="width:140px" %) |(% style="width:142px" %) 66 66 |Ready to charge|Signal showing that the battery is ready for charging|Yes|Yes|Yes|(% style="width:140px" %)Ready to charge|RTC|(% style="width:140px" %) |(% style="width:142px" %) 67 67 |Ready to discharge|Signal showing that the battery is ready for discharging|Yes|Yes|Yes|(% style="width:140px" %)Ready to disch.|RTD|(% style="width:140px" %) |(% style="width:142px" %) 68 -|Service reset|Command to restart the device|Yes*|Yes|Yes*|(% style="width:140px" %)Service reset|SR|(% style="width:140px" %) |(% style="width:142px" %) 69 -|Shutdown request (Combilift)|Command to open the dischrging contactor from the Combilift truck|Yes ~*~**|Yes~*~**|Yes*|(% style="width:140px" %)Combilift shutd.|CSH|(% style="width:140px" %) |(% style="width:142px" %)70 -|Shutdown request (HYG/Spirit)|Command to open the dischrging contactor from the HYG truck|Yes ~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)HYG shutdown|HSH|(% style="width:140px" %) |(% style="width:142px" %)71 -|Voltage too high for charging|Signal indicating that the battery is fully charged|Yes ~*~**|Yes~*~**|Yes~*~**|(% style="width:140px" %)Volt. too high|VTH|(% style="width:140px" %) |(% style="width:142px" %)68 +|Service reset|Command to restart the device|Yes*|Yes*|Yes*|(% style="width:140px" %)Service reset|SR|(% style="width:140px" %) |(% style="width:142px" %) 69 +|Shutdown request (Combilift)|Command to open the dischrging contactor from the Combilift truck|Yes*|Yes*|Yes*|(% style="width:140px" %)Combilift shutd.|CSH|(% style="width:140px" %) |(% style="width:142px" %) 70 +|Shutdown request (HYG/Spirit)|Command to open the dischrging contactor from the HYG truck|Yes*|Yes*|Yes*|(% style="width:140px" %)HYG shutdown|HSH|(% style="width:140px" %) |(% style="width:142px" %) 71 +|Voltage too high for charging|Signal indicating that the battery is fully charged|Yes*|Yes*|Yes*|(% style="width:140px" %)Volt. too high|VTH|(% style="width:140px" %) |(% style="width:142px" %) 72 72 73 73 (% class="wikigeneratedid" %) 74 -~* Assignable to relayonly74 +~* Cannot be assigned to discrete outputs and relays. 75 75 76 -(% class="wikigeneratedid" %) 77 -~** Assignable to discrete input only 78 - 79 -(% class="wikigeneratedid" %) 80 -~*~*~* Cannot be assigned to discrete output or relay. 81 - 82 82 == Errors == 83 83 84 84 (% style="width:1279px" %)