Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -109,7 +109,7 @@ 109 109 |HVIL error|Breakage of high-voltage interlock current loop|•| | |Yes|(% style="width:142px" %) |HE|(% style="width:142px" %) |(% style="width:134px" %) 110 110 |HYG offline|Connection with the HYG forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %) |HYG|(% style="width:142px" %) |(% style="width:134px" %) 111 111 |Insulation fault| |•|Yes|Yes|Yes|(% style="width:142px" %) |INF|(% style="width:142px" %) |(% style="width:134px" %) 112 -|Logic count error| Thenumber of BMS Logic devices differs from the required value| | |Yes|Yes|(% style="width:142px" %) |LOG|(% style="width:142px" %) |(% style="width:134px" %)112 +|Logic count error| | | |Yes|Yes|(% style="width:142px" %) |LOG|(% style="width:142px" %) |(% style="width:134px" %) 113 113 |Logic offline 114 114 Cell monitor offline|BMS Main devices: at least one of the Logic devices is offline. 115 115 BMS Mini devices: connection with cell monitor is lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |LOF|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -134,7 +134,7 @@ 134 134 |Temperature sensor is shorted|Some temperature sensors are shorted|•|Yes|Yes|Yes|(% style="width:142px" %) |TSS|(% style="width:142px" %) |(% style="width:134px" %) 135 135 |Unallowable charging|Charging the battery through the discharging contactor| |Yes|Yes|Yes|(% style="width:142px" %) |UCH|(% style="width:142px" %) |(% style="width:134px" %) 136 136 |Undervoltage|Voltage of any cell is too low| |Yes|Yes|Yes|(% style="width:142px" %) |UV|(% style="width:142px" %) |(% style="width:134px" %) 137 -|Water|There is water in the battery enclosure|•| |Yes|Yes|(% style="width:142px" %) |WA|(% style="width:142px" %) |(% style="width:134px" %) 138 -|WDT reset| Watchdog timer reset the device|•|Yes|Yes|Yes|(% style="width:142px" %) |WDT|(% style="width:142px" %) |(% style="width:134px" %)137 +|Water|There is water in the battery enclosure;|•| |Yes|Yes|(% style="width:142px" %) |WA|(% style="width:142px" %) |(% style="width:134px" %) 138 +|WDT reset|watchdog timer reset the device;|•|Yes|Yes|Yes|(% style="width:142px" %) |WDT|(% style="width:142px" %) |(% style="width:134px" %) 139 139 140 140 ~* signal can be assigned to a discrete output and relay.