Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -84,8 +84,8 @@ 84 84 (% style="width:1279px" %) 85 85 |(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="3" rowspan="1" style="width:248px" %)**Compability**|(% colspan="2" rowspan="1" style="width:142px" %)**BMS Display**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus** 86 86 |=(% style="width: 93px;" %)**Mini S / Mini**|=(% style="width: 76px;" %)**Main 2.1**|=(% style="width: 80px;" %)**Main 3**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 137px;" %)Abbreviation 87 -|ADC error|Error of the ADC that measures the battery current|•|Yes|Yes|Yes|(% style="width:142px" %) |ADC|(% style="width:142px" %) |(% style="width:134px" %) 88 -|Battery cover error|Battery cover is open|•|Yes|Yes|Yes|(% style="width:142px" %) |BC|(% style="width:142px" %) |(% style="width:134px" %) 87 +|ADC error|Error of the ADC that measures the battery current|•|Yes|Yes|Yes|(% style="width:142px" %)ADC error|ADC|(% style="width:142px" %) |(% style="width:134px" %) 88 +|Battery cover error|Battery cover is open|•|Yes|Yes|Yes|(% style="width:142px" %)Battery cover|BCE|(% style="width:142px" %) |(% style="width:134px" %) 89 89 |Cell count error|Number of cells does not match the specified value|•|Yes|Yes|Yes|(% style="width:142px" %) |CEL|(% style="width:142px" %) |(% style="width:134px" %) 90 90 |CH contactor cycles error|Switching frequency of the charging contactor is too high| |Yes|Yes|Yes|(% style="width:142px" %) |CCC|(% style="width:142px" %) |(% style="width:134px" %) 91 91 |CH contactor feedback error|The control signal for the charging contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %) |CCF|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -108,8 +108,8 @@ 108 108 |High voltage fault|Failure of high voltage measuring circuits|•| | |Yes|(% style="width:142px" %) |HVF|(% style="width:142px" %) |(% style="width:134px" %) 109 109 |HVIL error|Breakage of high-voltage interlock current loop|•| | |Yes|(% style="width:142px" %) |HE|(% style="width:142px" %) |(% style="width:134px" %) 110 110 |HYG offline|Connection with the HYG forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %) |HYG|(% style="width:142px" %) |(% style="width:134px" %) 111 -|Insulation fault| |•|Yes|Yes|Yes|(% style="width:142px" %) |INF|(% style="width:142px" %) |(% style="width:134px" %) 112 -|Logic count error| | | |Yes|Yes|(% style="width:142px" %) |LOG|(% style="width:142px" %) |(% style="width:134px" %) 111 +|Insulation fault|Insulation resistance is too low|•|Yes|Yes|Yes|(% style="width:142px" %) |INF|(% style="width:142px" %) |(% style="width:134px" %) 112 +|Logic count error|The number of BMS Logic devices differs from the required value| | |Yes|Yes|(% style="width:142px" %) |LOG|(% style="width:142px" %) |(% style="width:134px" %) 113 113 |Logic offline 114 114 Cell monitor offline|BMS Main devices: at least one of the Logic devices is offline. 115 115 BMS Mini devices: connection with cell monitor is lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |LOF|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -130,11 +130,11 @@ 130 130 |Shunt error|Internal error of the shunt current sensor|•|Yes|Yes|Yes|(% style="width:142px" %) |SHE|(% style="width:142px" %) |(% style="width:134px" %) 131 131 |Shunt offline|Connection with the shunt current sensor is lost|•|Yes|Yes|Yes|(% style="width:142px" %) |SHO|(% style="width:142px" %) |(% style="width:134px" %) 132 132 |Spirit offline|Connection with the Spirit forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %) |SPI|(% style="width:142px" %) |(% style="width:134px" %) 133 -|Stuck contactor| |•|Yes|Yes|Yes|(% style="width:142px" %) |STC|(% style="width:142px" %) |(% style="width:134px" %) 133 +|Stuck contactor|Some contactor got stuck|•|Yes|Yes|Yes|(% style="width:142px" %) |STC|(% style="width:142px" %) |(% style="width:134px" %) 134 134 |Temperature sensor is shorted|Some temperature sensors are shorted|•|Yes|Yes|Yes|(% style="width:142px" %) |TSS|(% style="width:142px" %) |(% style="width:134px" %) 135 135 |Unallowable charging|Charging the battery through the discharging contactor| |Yes|Yes|Yes|(% style="width:142px" %) |UCH|(% style="width:142px" %) |(% style="width:134px" %) 136 -|Undervoltage| | |Yes|Yes|Yes|(% style="width:142px" %) |UV|(% style="width:142px" %) |(% style="width:134px" %) 137 -|Water| there is water in the battery enclosure;|•| |Yes|Yes|(% style="width:142px" %) |WA|(% style="width:142px" %) |(% style="width:134px" %)138 -|WDT reset| watchdog timer reset the device;|•|Yes|Yes|Yes|(% style="width:142px" %) |WDT|(% style="width:142px" %) |(% style="width:134px" %)136 +|Undervoltage|Voltage of any cell is too low| |Yes|Yes|Yes|(% style="width:142px" %) |UV|(% style="width:142px" %) |(% style="width:134px" %) 137 +|Water|There is water in the battery enclosure|•| |Yes|Yes|(% style="width:142px" %) |WA|(% style="width:142px" %) |(% style="width:134px" %) 138 +|WDT reset|Watchdog timer reset the device|•|Yes|Yes|Yes|(% style="width:142px" %) |WDT|(% style="width:142px" %) |(% style="width:134px" %) 139 139 140 -~* signal can be assigned to adiscrete output and relay.140 +~* The signal can be assigned to discrete outputs and relays.