Last modified by Admin on 2025/03/03 15:20

From version 20.18
edited by Admin
on 2025/01/31 10:52
Change comment: There is no comment for this version
To version 21.2
edited by Admin
on 2025/01/31 11:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -84,8 +84,8 @@
84 84  (% style="width:1279px" %)
85 85  |(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="3" rowspan="1" style="width:248px" %)**Compability**|(% colspan="2" rowspan="1" style="width:142px" %)**BMS Display**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus**
86 86  |=(% style="width: 93px;" %)**Mini S / Mini**|=(% style="width: 76px;" %)**Main 2.1**|=(% style="width: 80px;" %)**Main 3**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 137px;" %)Abbreviation
87 -|ADC error|Error of the ADC that measures the battery current|•|Yes|Yes|Yes|(% style="width:142px" %) |ADC|(% style="width:142px" %) |(% style="width:134px" %)
88 -|Battery cover error|Battery cover is open|•|Yes|Yes|Yes|(% style="width:142px" %) |BC|(% style="width:142px" %) |(% style="width:134px" %)
87 +|ADC error|Error of the ADC that measures the battery current|•|Yes|Yes|Yes|(% style="width:142px" %)ADC error|ADC|(% style="width:142px" %) |(% style="width:134px" %)
88 +|Battery cover error|Battery cover is open|•|Yes|Yes|Yes|(% style="width:142px" %)Battery cover|BCE|(% style="width:142px" %) |(% style="width:134px" %)
89 89  |Cell count error|Number of cells does not match the specified value|•|Yes|Yes|Yes|(% style="width:142px" %) |CEL|(% style="width:142px" %) |(% style="width:134px" %)
90 90  |CH contactor cycles error|Switching frequency of the charging contactor is too high| |Yes|Yes|Yes|(% style="width:142px" %) |CCC|(% style="width:142px" %) |(% style="width:134px" %)
91 91  |CH contactor feedback error|The control signal for the charging contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %) |CCF|(% style="width:142px" %) |(% style="width:134px" %)
... ... @@ -108,8 +108,8 @@
108 108  |High voltage fault|Failure of high voltage measuring circuits|•| | |Yes|(% style="width:142px" %) |HVF|(% style="width:142px" %) |(% style="width:134px" %)
109 109  |HVIL error|Breakage of high-voltage interlock current loop|•| | |Yes|(% style="width:142px" %) |HE|(% style="width:142px" %) |(% style="width:134px" %)
110 110  |HYG offline|Connection with the HYG forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %) |HYG|(% style="width:142px" %) |(% style="width:134px" %)
111 -|Insulation fault| |•|Yes|Yes|Yes|(% style="width:142px" %) |INF|(% style="width:142px" %) |(% style="width:134px" %)
112 -|Logic count error| | | |Yes|Yes|(% style="width:142px" %) |LOG|(% style="width:142px" %) |(% style="width:134px" %)
111 +|Insulation fault|Insulation resistance is too low|•|Yes|Yes|Yes|(% style="width:142px" %) |INF|(% style="width:142px" %) |(% style="width:134px" %)
112 +|Logic count error|The number of BMS Logic devices differs from the required value| | |Yes|Yes|(% style="width:142px" %) |LOG|(% style="width:142px" %) |(% style="width:134px" %)
113 113  |Logic offline
114 114  Cell monitor offline|BMS Main devices: at least one of the Logic devices is offline.
115 115  BMS Mini devices: connection with cell monitor is lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |LOF|(% style="width:142px" %) |(% style="width:134px" %)
... ... @@ -125,16 +125,16 @@
125 125  |Power fault|External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|•| | |Yes|(% style="width:142px" %) |PF|(% style="width:142px" %) |(% style="width:134px" %)
126 126  |Power switch error|Short circuit in contactor coil control circuit or power switch overheating|•| | |Yes|(% style="width:142px" %) |PSE|(% style="width:142px" %) |(% style="width:134px" %)
127 127  |Precharge error|Capacitive load pre-charge process did not end during the estimated time| |Yes|Yes|Yes|(% style="width:142px" %) |PE|(% style="width:142px" %) |(% style="width:134px" %)
128 -|Settings error| | | | | |(% style="width:142px" %) |SET|(% style="width:142px" %) |(% style="width:134px" %)
129 -|Short circuit| | |Yes|Yes|Yes|(% style="width:142px" %) |SHC|(% style="width:142px" %) |(% style="width:134px" %)
130 -|Shunt error|internal error of the shunt current sensor;|•|Yes|Yes|Yes|(% style="width:142px" %) |SHE|(% style="width:142px" %) |(% style="width:134px" %)
131 -|Shunt offline|connection with the shunt current sensor is lost;|•|Yes|Yes|Yes|(% style="width:142px" %) |SHO|(% style="width:142px" %) |(% style="width:134px" %)
132 -|Spirit offline|connection with a Spirit forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |SPI|(% style="width:142px" %) |(% style="width:134px" %)
133 -|Stuck contactor| |•|Yes|Yes|Yes|(% style="width:142px" %) |STC|(% style="width:142px" %) |(% style="width:134px" %)
134 -|Temperature sensor is shorted|some temperature sensors are shorted;|•|Yes|Yes|Yes|(% style="width:142px" %) |TSS|(% style="width:142px" %) |(% style="width:134px" %)
135 -|Unallowable charging|charging the battery through the discharging contactor;| |Yes|Yes|Yes|(% style="width:142px" %) |UCH|(% style="width:142px" %) |(% style="width:134px" %)
136 -|Undervoltage| | |Yes|Yes|Yes|(% style="width:142px" %) |UV|(% style="width:142px" %) |(% style="width:134px" %)
137 -|Water|there is water in the battery enclosure;|•| |Yes|Yes|(% style="width:142px" %) |WA|(% style="width:142px" %) |(% style="width:134px" %)
138 -|WDT reset|watchdog timer reset the device;|•|Yes|Yes|Yes|(% style="width:142px" %) |WDT|(% style="width:142px" %) |(% style="width:134px" %)
128 +|Settings error|Wrong checksum of the device settings| | |Yes| |(% style="width:142px" %) |SET|(% style="width:142px" %) |(% style="width:134px" %)
129 +|Short circuit|Flowing high battery currents during a long time| |Yes|Yes|Yes|(% style="width:142px" %) |SHC|(% style="width:142px" %) |(% style="width:134px" %)
130 +|Shunt error|Internal error of the shunt current sensor|•|Yes|Yes|Yes|(% style="width:142px" %) |SHE|(% style="width:142px" %) |(% style="width:134px" %)
131 +|Shunt offline|Connection with the shunt current sensor is lost|•|Yes|Yes|Yes|(% style="width:142px" %) |SHO|(% style="width:142px" %) |(% style="width:134px" %)
132 +|Spirit offline|Connection with the Spirit forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %) |SPI|(% style="width:142px" %) |(% style="width:134px" %)
133 +|Stuck contactor|Some contactor got stuck|•|Yes|Yes|Yes|(% style="width:142px" %) |STC|(% style="width:142px" %) |(% style="width:134px" %)
134 +|Temperature sensor is shorted|Some temperature sensors are shorted|•|Yes|Yes|Yes|(% style="width:142px" %) |TSS|(% style="width:142px" %) |(% style="width:134px" %)
135 +|Unallowable charging|Charging the battery through the discharging contactor| |Yes|Yes|Yes|(% style="width:142px" %) |UCH|(% style="width:142px" %) |(% style="width:134px" %)
136 +|Undervoltage|Voltage of any cell is too low| |Yes|Yes|Yes|(% style="width:142px" %) |UV|(% style="width:142px" %) |(% style="width:134px" %)
137 +|Water|There is water in the battery enclosure|•| |Yes|Yes|(% style="width:142px" %) |WA|(% style="width:142px" %) |(% style="width:134px" %)
138 +|WDT reset|Watchdog timer reset the device|•|Yes|Yes|Yes|(% style="width:142px" %) |WDT|(% style="width:142px" %) |(% style="width:134px" %)
139 139  
140 -~* signal can be assigned to a discrete output and relay.
140 +~* The signal can be assigned to discrete outputs and relays.