Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -108,8 +108,8 @@ 108 108 |High voltage fault|Failure of high voltage measuring circuits|•| | |Yes|(% style="width:142px" %) |HVF|(% style="width:142px" %) |(% style="width:134px" %) 109 109 |HVIL error|Breakage of high-voltage interlock current loop|•| | |Yes|(% style="width:142px" %) |HE|(% style="width:142px" %) |(% style="width:134px" %) 110 110 |HYG offline|Connection with the HYG forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %) |HYG|(% style="width:142px" %) |(% style="width:134px" %) 111 -|Insulation fault| |•|Yes|Yes|Yes|(% style="width:142px" %) |INF|(% style="width:142px" %) |(% style="width:134px" %) 112 -|Logic count error| | | |Yes|Yes|(% style="width:142px" %) |LOG|(% style="width:142px" %) |(% style="width:134px" %) 111 +|Insulation fault|Insulation resistance is too low|•|Yes|Yes|Yes|(% style="width:142px" %) |INF|(% style="width:142px" %) |(% style="width:134px" %) 112 +|Logic count error|The number of BMS Logic devices differs from the required value| | |Yes|Yes|(% style="width:142px" %) |LOG|(% style="width:142px" %) |(% style="width:134px" %) 113 113 |Logic offline 114 114 Cell monitor offline|BMS Main devices: at least one of the Logic devices is offline. 115 115 BMS Mini devices: connection with cell monitor is lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |LOF|(% style="width:142px" %) |(% style="width:134px" %) ... ... @@ -124,17 +124,17 @@ 124 124 |PCH contactor feedback error|The control signal for the precharging contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %) |PCF|(% style="width:142px" %) |(% style="width:134px" %) 125 125 |Power fault|External devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices|•| | |Yes|(% style="width:142px" %) |PF|(% style="width:142px" %) |(% style="width:134px" %) 126 126 |Power switch error|Short circuit in contactor coil control circuit or power switch overheating|•| | |Yes|(% style="width:142px" %) |PSE|(% style="width:142px" %) |(% style="width:134px" %) 127 -|Precharge error| capacitive load pre-charge process did not end during the estimated time;| |Yes|Yes|Yes|(% style="width:142px" %) |PE|(% style="width:142px" %) |(% style="width:134px" %)128 -|Settings error| || | | |(% style="width:142px" %) |SET|(% style="width:142px" %) |(% style="width:134px" %)129 -|Short circuit| | |Yes|Yes|Yes|(% style="width:142px" %) |SHC|(% style="width:142px" %) |(% style="width:134px" %) 130 -|Shunt error| internal error of the shunt current sensor;|•|Yes|Yes|Yes|(% style="width:142px" %) |SHE|(% style="width:142px" %) |(% style="width:134px" %)131 -|Shunt offline| connection with the shunt current sensor is lost;|•|Yes|Yes|Yes|(% style="width:142px" %) |SHO|(% style="width:142px" %) |(% style="width:134px" %)132 -|Spirit offline| connection withaSpirit forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |SPI|(% style="width:142px" %) |(% style="width:134px" %)127 +|Precharge error|Capacitive load pre-charge process did not end during the estimated time| |Yes|Yes|Yes|(% style="width:142px" %) |PE|(% style="width:142px" %) |(% style="width:134px" %) 128 +|Settings error|Wrong checksum of the device settings| | |Yes| |(% style="width:142px" %) |SET|(% style="width:142px" %) |(% style="width:134px" %) 129 +|Short circuit|Flowing high battery currents during a long time| |Yes|Yes|Yes|(% style="width:142px" %) |SHC|(% style="width:142px" %) |(% style="width:134px" %) 130 +|Shunt error|Internal error of the shunt current sensor|•|Yes|Yes|Yes|(% style="width:142px" %) |SHE|(% style="width:142px" %) |(% style="width:134px" %) 131 +|Shunt offline|Connection with the shunt current sensor is lost|•|Yes|Yes|Yes|(% style="width:142px" %) |SHO|(% style="width:142px" %) |(% style="width:134px" %) 132 +|Spirit offline|Connection with the Spirit forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %) |SPI|(% style="width:142px" %) |(% style="width:134px" %) 133 133 |Stuck contactor| |•|Yes|Yes|Yes|(% style="width:142px" %) |STC|(% style="width:142px" %) |(% style="width:134px" %) 134 -|Temperature sensor is shorted| some temperature sensors are shorted;|•|Yes|Yes|Yes|(% style="width:142px" %) |TSS|(% style="width:142px" %) |(% style="width:134px" %)135 -|Unallowable charging| charging the battery through the discharging contactor;| |Yes|Yes|Yes|(% style="width:142px" %) |UCH|(% style="width:142px" %) |(% style="width:134px" %)136 -|Undervoltage| | |Yes|Yes|Yes|(% style="width:142px" %) |UV|(% style="width:142px" %) |(% style="width:134px" %) 137 -|Water| there is water in the battery enclosure;|•| |Yes|Yes|(% style="width:142px" %) |WA|(% style="width:142px" %) |(% style="width:134px" %)138 -|WDT reset| watchdog timer reset the device;|•|Yes|Yes|Yes|(% style="width:142px" %) |WDT|(% style="width:142px" %) |(% style="width:134px" %)134 +|Temperature sensor is shorted|Some temperature sensors are shorted|•|Yes|Yes|Yes|(% style="width:142px" %) |TSS|(% style="width:142px" %) |(% style="width:134px" %) 135 +|Unallowable charging|Charging the battery through the discharging contactor| |Yes|Yes|Yes|(% style="width:142px" %) |UCH|(% style="width:142px" %) |(% style="width:134px" %) 136 +|Undervoltage|Voltage of any cell is too low| |Yes|Yes|Yes|(% style="width:142px" %) |UV|(% style="width:142px" %) |(% style="width:134px" %) 137 +|Water|There is water in the battery enclosure|•| |Yes|Yes|(% style="width:142px" %) |WA|(% style="width:142px" %) |(% style="width:134px" %) 138 +|WDT reset|Watchdog timer reset the device|•|Yes|Yes|Yes|(% style="width:142px" %) |WDT|(% style="width:142px" %) |(% style="width:134px" %) 139 139 140 140 ~* signal can be assigned to a discrete output and relay.