... ... @@ -115,12 +115,12 @@
115 115  BMS Mini devices: connection with cell monitor is lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |LOF|(% style="width:142px" %) |(% style="width:134px" %)
116 116  |Low temperature (CH)|Temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |LCT|(% style="width:142px" %) |(% style="width:134px" %)
117 117  |Low temperature (DCH)|Temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |LDT|(% style="width:142px" %) |(% style="width:134px" %)
118 -|Main contactor feedback error|The control signal for the main contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %) |MCF|(% style="width:142px" %) |(% style="width:134px" %)
119 -|Mount error|SD card cannot be mounted| |Yes|Yes|Yes|(% style="width:142px" %) |MNT|(% style="width:142px" %) |(% style="width:134px" %)
120 -|Need acknowledge|There is an unacknowledged error in error journal| |Yes|Yes|Yes|(% style="width:142px" %) |ACK|(% style="width:142px" %) |(% style="width:134px" %)
121 -|No temperature sensors|The device has no temperature sensors connected|•|Yes|Yes|Yes|(% style="width:142px" %) |NTS|(% style="width:142px" %) |(% style="width:134px" %)
122 -|Overcurrent|The battery current is too high| |Yes|Yes|Yes|(% style="width:142px" %) |OC|(% style="width:142px" %) |(% style="width:134px" %)
123 -|Overvoltage|The | |Yes|Yes|Yes|(% style="width:142px" %) |OV|(% style="width:142px" %) |(% style="width:134px" %)
118 +|Main contactor feedback error|The control signals for the main contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |MCF|(% style="width:142px" %) |(% style="width:134px" %)
119 +|Mount error| | |Yes|Yes|Yes|(% style="width:142px" %) |MNT|(% style="width:142px" %) |(% style="width:134px" %)
120 +|Need acknowledge|there is an unacknowledged error in Error journal;| |Yes|Yes|Yes|(% style="width:142px" %) |ACK|(% style="width:142px" %) |(% style="width:134px" %)
121 +|No temperature sensors|the device has no temperature sensors connected;|•|Yes|Yes|Yes|(% style="width:142px" %) |NTS|(% style="width:142px" %) |(% style="width:134px" %)
122 +|Overcurrent| | |Yes|Yes|Yes|(% style="width:142px" %) |OC|(% style="width:142px" %) |(% style="width:134px" %)
123 +|Overvoltage| | |Yes|Yes|Yes|(% style="width:142px" %) |OV|(% style="width:142px" %) |(% style="width:134px" %)
124 124  |PCH contactor feedback error|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |PCF|(% style="width:142px" %) |(% style="width:134px" %)
125 125  |Power fault|external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|•| | |Yes|(% style="width:142px" %) |PF|(% style="width:142px" %) |(% style="width:134px" %)
126 126  |Power switch error|short circuit in contactor coil control circuit or power switch overheating;|•| | |Yes|(% style="width:142px" %) |PSE|(% style="width:142px" %) |(% style="width:134px" %)