Last modified by Admin on 2025/03/03 15:20

From version 20.12
edited by Admin
on 2025/01/31 10:50
Change comment: There is no comment for this version
To version 20.15
edited by Admin
on 2025/01/31 10:51
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -117,10 +117,10 @@
117 117  |Low temperature (DCH)|Temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |LDT|(% style="width:142px" %) |(% style="width:134px" %)
118 118  |Main contactor feedback error|The control signal for the main contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %) |MCF|(% style="width:142px" %) |(% style="width:134px" %)
119 119  |Mount error|SD card cannot be mounted| |Yes|Yes|Yes|(% style="width:142px" %) |MNT|(% style="width:142px" %) |(% style="width:134px" %)
120 -|Need acknowledge|there is an unacknowledged error in Error journal;| |Yes|Yes|Yes|(% style="width:142px" %) |ACK|(% style="width:142px" %) |(% style="width:134px" %)
121 -|No temperature sensors|the device has no temperature sensors connected;|•|Yes|Yes|Yes|(% style="width:142px" %) |NTS|(% style="width:142px" %) |(% style="width:134px" %)
122 -|Overcurrent| | |Yes|Yes|Yes|(% style="width:142px" %) |OC|(% style="width:142px" %) |(% style="width:134px" %)
123 -|Overvoltage| | |Yes|Yes|Yes|(% style="width:142px" %) |OV|(% style="width:142px" %) |(% style="width:134px" %)
120 +|Need acknowledge|There is an unacknowledged error in error journal| |Yes|Yes|Yes|(% style="width:142px" %) |ACK|(% style="width:142px" %) |(% style="width:134px" %)
121 +|No temperature sensors|The device has no temperature sensors connected|•|Yes|Yes|Yes|(% style="width:142px" %) |NTS|(% style="width:142px" %) |(% style="width:134px" %)
122 +|Overcurrent|The battery current is too high| |Yes|Yes|Yes|(% style="width:142px" %) |OC|(% style="width:142px" %) |(% style="width:134px" %)
123 +|Overvoltage|Some cell voltage is too high| |Yes|Yes|Yes|(% style="width:142px" %) |OV|(% style="width:142px" %) |(% style="width:134px" %)
124 124  |PCH contactor feedback error|the control signals for the precharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |PCF|(% style="width:142px" %) |(% style="width:134px" %)
125 125  |Power fault|external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;|•| | |Yes|(% style="width:142px" %) |PF|(% style="width:142px" %) |(% style="width:134px" %)
126 126  |Power switch error|short circuit in contactor coil control circuit or power switch overheating;|•| | |Yes|(% style="width:142px" %) |PSE|(% style="width:142px" %) |(% style="width:134px" %)