Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -101,18 +101,18 @@ 101 101 |FS error|SD card read/write error| |Yes|Yes|Yes|(% style="width:142px" %) |FSE|(% style="width:142px" %) |(% style="width:134px" %) 102 102 |General error|Special configurable error depending on other errors| |Yes*|Yes*|Yes*|(% style="width:142px" %) |GE|(% style="width:142px" %) |(% style="width:134px" %) 103 103 |High contactor temperature|Temperature of a contactor is too high| |Yes|Yes|Yes|(% style="width:142px" %) |CHT|(% style="width:142px" %) |(% style="width:134px" %) 104 -|High humidity| Increasedhumidityinsidethe battery| | |Yes|Yes|(% style="width:142px" %) |HH|(% style="width:142px" %) |(% style="width:134px" %)105 -|High Logic temperature| At least one of the Logic devices is overheated| | |Yes|Yes|(% style="width:142px" %) |LHT|(% style="width:142px" %) |(% style="width:134px" %)106 -|High temperature (CH)| Temperature is too high for charging| |Yes|Yes|Yes|(% style="width:142px" %) |HCT|(% style="width:142px" %) |(% style="width:134px" %)107 -|High temperature (DCH)| Temperature is too high for discharging| |Yes|Yes|Yes|(% style="width:142px" %) |HDT|(% style="width:142px" %) |(% style="width:134px" %)108 -|High voltage fault| Failure of high voltage measuring circuits|•| | |Yes|(% style="width:142px" %) |HVF|(% style="width:142px" %) |(% style="width:134px" %)109 -|HVIL error| Breakage of high-voltage interlock current loop|•| | |Yes|(% style="width:142px" %) |HE|(% style="width:142px" %) |(% style="width:134px" %)110 -|HYG offline| Connection withtheHYG forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %) |HYG|(% style="width:142px" %) |(% style="width:134px" %)104 +|High humidity|humidity of the battery is increased;| | |Yes|Yes|(% style="width:142px" %) |HH|(% style="width:142px" %) |(% style="width:134px" %) 105 +|High Logic temperature|at least one of the Logic devices is overheated;| | |Yes|Yes|(% style="width:142px" %) |LHT|(% style="width:142px" %) |(% style="width:134px" %) 106 +|High temperature (CH)|temperature is too high for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |HCT|(% style="width:142px" %) |(% style="width:134px" %) 107 +|High temperature (DCH)|temperature is too high for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |HDT|(% style="width:142px" %) |(% style="width:134px" %) 108 +|High voltage fault|failure of high voltage measuring circuits;|•| | |Yes|(% style="width:142px" %) |HVF|(% style="width:142px" %) |(% style="width:134px" %) 109 +|HVIL error|breakage of high-voltage interlock current loop;|•| | |Yes|(% style="width:142px" %) |HE|(% style="width:142px" %) |(% style="width:134px" %) 110 +|HYG offline|connection with a HYG forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |HYG|(% style="width:142px" %) |(% style="width:134px" %) 111 111 |Insulation fault| |•|Yes|Yes|Yes|(% style="width:142px" %) |INF|(% style="width:142px" %) |(% style="width:134px" %) 112 112 |Logic count error| | | |Yes|Yes|(% style="width:142px" %) |LOG|(% style="width:142px" %) |(% style="width:134px" %) 113 113 |Logic offline 114 114 Cell monitor offline|BMS Main devices: at least one of the Logic devices is offline; 115 -BMS Mini devices: connection with cell monitor islost.|•|Yes|Yes|Yes|(% style="width:142px" %) |LOF|(% style="width:142px" %) |(% style="width:134px" %)115 +BMS Mini devices: connection with cell monitor lost.|•|Yes|Yes|Yes|(% style="width:142px" %) |LOF|(% style="width:142px" %) |(% style="width:134px" %) 116 116 |Low temperature (CH)|temperature is too low for charging;| |Yes|Yes|Yes|(% style="width:142px" %) |LCT|(% style="width:142px" %) |(% style="width:134px" %) 117 117 |Low temperature (DCH)|temperature is too low for discharging;| |Yes|Yes|Yes|(% style="width:142px" %) |LDT|(% style="width:142px" %) |(% style="width:134px" %) 118 118 |Main contactor feedback error|the control signals for the main contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |MCF|(% style="width:142px" %) |(% style="width:134px" %)