Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -79,25 +79,25 @@ 79 79 (% class="wikigeneratedid" %) 80 80 ~*~*~* Cannot be assigned to discrete output or relay. 81 81 82 -== List of errors ==82 +== Errors == 83 83 84 84 (% style="width:1279px" %) 85 85 |(% colspan="1" rowspan="2" style="width:196px" %)**Name **|(% colspan="1" rowspan="2" style="width:443px" %)**Description**|(% colspan="1" rowspan="2" style="width:67px" %)**Is a Critical error?**|(% colspan="3" rowspan="1" style="width:248px" %)**Compability**|(% colspan="2" rowspan="1" style="width:142px" %)**BMS Display**|(% colspan="1" rowspan="2" style="width:142px" %)**CANopen SDO**|(% colspan="1" rowspan="2" style="width:134px" %)**Modbus** 86 86 |=(% style="width: 93px;" %)**Mini S / Mini**|=(% style="width: 76px;" %)**Main 2.1**|=(% style="width: 80px;" %)**Main 3**|=(% colspan="1" style="width: 137px;" %)Short name|=(% style="width: 137px;" %)Abbreviation 87 -|ADC error| currentcannotbe measured;|•|Yes|Yes|Yes|(% style="width:142px" %) |ADC|(% style="width:142px" %) |(% style="width:134px" %)88 -|Battery cover error| battery cover is open;|•|Yes|Yes|Yes|(% style="width:142px" %) |BC|(% style="width:142px" %) |(% style="width:134px" %)89 -|Cell count error| number of cells does not match the specified value;|•|Yes|Yes|Yes|(% style="width:142px" %) |CEL|(% style="width:142px" %) |(% style="width:134px" %)90 -|CH contactor cycles error| switching frequency of the charging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |CCC|(% style="width:142px" %) |(% style="width:134px" %)91 -|CH contactor feedback error| the control signalsfor the charging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |CCF|(% style="width:142px" %) |(% style="width:134px" %)92 -|CH/DCH contactor feedback error| the control signalsfor the charging/discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |CDF|(% style="width:142px" %) |(% style="width:134px" %)93 -|Combilift offline| connection withaCombilift forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |COM|(% style="width:142px" %) |(% style="width:134px" %)94 -|Contactor feedback error|Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of BMS Mini device| |Yes| | |(% style="width:142px" %) |CFE|(% style="width:142px" %) |(% style="width:134px" %) 95 -|Critical error| | |Yes|Yes|Yes|(% style="width:142px" %) |CER|(% style="width:142px" %) |(% style="width:134px" %) 96 -|Crown error| connection withaCrown forklift is lost;| |Yes|Yes|Yes|(% style="width:142px" %) |CRO|(% style="width:142px" %) |(% style="width:134px" %)97 -|Current limit error| charging or discharging current is more than limit calculated by Charge map or Discharge map.| |Yes| |Yes|(% style="width:142px" %) |CLE|(% style="width:142px" %) |(% style="width:134px" %)98 -|Current sensor error| error in the current sensor circuit;|•|Yes|Yes|Yes|(% style="width:142px" %) |CSE|(% style="width:142px" %) |(% style="width:134px" %)99 -|DCH contactor cycles error| switching frequency of the discharging contactor is too high;| |Yes|Yes|Yes|(% style="width:142px" %) |DCC|(% style="width:142px" %) |(% style="width:134px" %)100 -|DCH contactor feedback error| the control signals for the discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |DCF|(% style="width:142px" %) |(% style="width:134px" %)87 +|ADC error|Error of the ADC that measures the battery current|•|Yes|Yes|Yes|(% style="width:142px" %) |ADC|(% style="width:142px" %) |(% style="width:134px" %) 88 +|Battery cover error|Battery cover is open|•|Yes|Yes|Yes|(% style="width:142px" %) |BC|(% style="width:142px" %) |(% style="width:134px" %) 89 +|Cell count error|Number of cells does not match the specified value|•|Yes|Yes|Yes|(% style="width:142px" %) |CEL|(% style="width:142px" %) |(% style="width:134px" %) 90 +|CH contactor cycles error|Switching frequency of the charging contactor is too high| |Yes|Yes|Yes|(% style="width:142px" %) |CCC|(% style="width:142px" %) |(% style="width:134px" %) 91 +|CH contactor feedback error|The control signal for the charging contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %) |CCF|(% style="width:142px" %) |(% style="width:134px" %) 92 +|CH/DCH contactor feedback error|The control signal for the charging/discharging contactor and the contactor feedback differ|•| |Yes|Yes|(% style="width:142px" %) |CDF|(% style="width:142px" %) |(% style="width:134px" %) 93 +|Combilift offline|Connection with the Combilift forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %) |COM|(% style="width:142px" %) |(% style="width:134px" %) 94 +|Contactor feedback error|Failure of one of the contactors feedback signal. Which contactor is failed can be found in "Signals -> MOSFETs -> Contactor feedback" section of the BMS Mini device| |Yes| | |(% style="width:142px" %) |CFE|(% style="width:142px" %) |(% style="width:134px" %) 95 +|Critical error|Critical system error, the BMS is damaged| |Yes|Yes|Yes|(% style="width:142px" %) |CER|(% style="width:142px" %) |(% style="width:134px" %) 96 +|Crown error|Connection with the Crown forklift is lost| |Yes|Yes|Yes|(% style="width:142px" %) |CRO|(% style="width:142px" %) |(% style="width:134px" %) 97 +|Current limit error|Charging or discharging current is more than the limit calculated by Charge map or Discharge map| |Yes| |Yes|(% style="width:142px" %) |CLE|(% style="width:142px" %) |(% style="width:134px" %) 98 +|Current sensor error|Error in the current sensor circuit|•|Yes|Yes|Yes|(% style="width:142px" %) |CSE|(% style="width:142px" %) |(% style="width:134px" %) 99 +|DCH contactor cycles error|Switching frequency of the discharging contactor is too high| |Yes|Yes|Yes|(% style="width:142px" %) |DCC|(% style="width:142px" %) |(% style="width:134px" %) 100 +|DCH contactor feedback error|The control signals for the discharging contactor and the contactor feedback differ;|•| |Yes|Yes|(% style="width:142px" %) |DCF|(% style="width:142px" %) |(% style="width:134px" %) 101 101 |FS error| | |Yes|Yes|Yes|(% style="width:142px" %) |FSE|(% style="width:142px" %) |(% style="width:134px" %) 102 102 |General error| | |Yes*|Yes*|Yes*|(% style="width:142px" %) |GE|(% style="width:142px" %) |(% style="width:134px" %) 103 103 |High contactor temperature| | |Yes|Yes|Yes|(% style="width:142px" %) |CHT|(% style="width:142px" %) |(% style="width:134px" %)