8 8  
9 9  Here is the list of available input signals of BMS Main 3.
10 10  
11 -(% style="width:1227px" %)
12 -|(% colspan="1" rowspan="2" style="width:216px" %)**Name**|(% rowspan="2" style="width:77px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:395px" %)**Description**|(% colspan="1" rowspan="2" style="width:258px" %)**Used by**|(% colspan="3" rowspan="1" style="width:160px" %)**Set up by**
13 -|(% style="width:112px" %)**Discrete input**|(% style="width:159px" %)**CAN**|(% style="width:159px" %)**Modbus**
14 -|(% style="width:216px" %)Battery cover |(% style="width:77px" %) |(% style="width:395px" %) a signal from the battery cover;|(% style="width:258px" %)Battery cover protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
15 -|(% style="width:216px" %)Charger connected |(% style="width:77px" %) |(% style="width:395px" %) a signal indicating that charger is connected;|(% style="width:258px" %)Charge controller, Discharge controller|(% style="width:112px" %)•|(% style="width:159px" %)• (if corresponding External equipment is online)|(% style="width:159px" %)
16 -|(% style="width:216px" %)Power up/down request |(% style="width:77px" %) |(% style="width:395px" %) a request to power down the device;|(% style="width:258px" %)Power down controller|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
17 -|(% style="width:216px" %)Inhibit charging |(% style="width:77px" %) |(% style="width:395px" %) a command to open the charging contactor;|(% style="width:258px" %) |(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
18 -|(% style="width:216px" %)Inhibit discharging |(% style="width:77px" %) |(% style="width:395px" %) a command to open the discharging contactor;|(% style="width:258px" %) |(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
19 -|(% style="width:216px" %)CH contactor feedback |(% style="width:77px" %) |(% style="width:395px" %) a signal from charging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
20 -|(% style="width:216px" %)DCH contactor feedback |(% style="width:77px" %) |(% style="width:395px" %) a signal from discharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
21 -|(% style="width:216px" %)Insulation status |(% style="width:77px" %) |(% style="width:395px" %) a signal from an insulation monitoring device;|(% style="width:258px" %)Insulation protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
22 -|(% style="width:216px" %)Charge request |(% style="width:77px" %) |(% style="width:395px" %) a request to close the charging contactor;|(% style="width:258px" %)Charge controller|(% style="width:112px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %)
23 -|(% style="width:216px" %)Discharge request |(% style="width:77px" %) |(% style="width:395px" %) a request to close the discharging contactor;|(% style="width:258px" %)Discharge controller|(% style="width:112px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %)
24 -|(% style="width:216px" %)PCH contactor feedback |(% style="width:77px" %) |(% style="width:395px" %) a signal from precharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
25 -|(% style="width:216px" %)CH/DCH contactor feedback |(% style="width:77px" %) |(% style="width:395px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
26 -|(% style="width:216px" %)Main contactor feedback |(% style="width:77px" %) |(% style="width:395px" %) a signal from main contactor feedback loop;|(% style="width:258px" %)Contactor feedback protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
27 -|(% style="width:216px" %)Interlock |(% style="width:77px" %) |(% style="width:395px" %) a signal from interlock loop;|(% style="width:258px" %)Interlock protection|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
28 -|(% style="width:216px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:77px" %) |(% style="width:395px" %) signals from fuses;|(% style="width:258px" %) |(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
29 -|(% style="width:216px" %)Circuit breaker status |(% style="width:77px" %) |(% style="width:395px" %) status of protection disconnector;|(% style="width:258px" %) |(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
30 -|(% style="width:216px" %)Balancing request |(% style="width:77px" %) |(% style="width:395px" %) a request to balance the cells;|(% style="width:258px" %)Cell balance controller|(% style="width:112px" %)•|(% style="width:159px" %)•|(% style="width:159px" %)
31 -|(% style="width:216px" %)Close Main contactor |(% style="width:77px" %) |(% style="width:395px" %) a request to close the main contactor;|(% style="width:258px" %)Main contactor controller|(% style="width:112px" %)•|(% style="width:159px" %)• (by request)|(% style="width:159px" %)
32 -|(% style="width:216px" %)Close External 1 |(% style="width:77px" %) |(% style="width:395px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:258px" %)External 1 internal state|(% style="width:112px" %)•|(% style="width:159px" %) |(% style="width:159px" %)
11 +(% style="width:1093px" %)
12 +|(% colspan="1" rowspan="2" style="width:131px" %)**Name**|(% rowspan="2" style="width:43px" %)**Abbr.**|(% colspan="1" rowspan="2" style="width:302px" %)**Description**|(% colspan="1" rowspan="2" style="width:187px" %)**Used by**|(% colspan="3" rowspan="1" style="width:426px" %)**Set up by**
13 +|(% style="width:92px" %)**Dis. input**|(% style="width:268px" %)**CAN**|(% style="width:65px" %)**Modbus**
14 +|(% style="width:131px" %)Battery cover |(% style="width:43px" %) |(% style="width:302px" %) a signal from the battery cover;|(% style="width:187px" %)Battery cover protection ([[Main 3>>doc:Battery management systems.BMS Main 3.3\. Configuration.3\.4 Protections.WebHome||anchor="HBatterycover"]], [[Main 2.1>>doc:Battery management systems.BMS Main 2\.1.3\. Configuration.3\.6 Battery protection.WebHome||anchor="HBatterycover"]], [[Mini S / Mini>>doc:Battery management systems.BMS Mini S.3\. Configuration.3\.4 Protections.WebHome||anchor="HBatterycover"]])|(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
15 +|(% style="width:131px" %)Charger connected |(% style="width:43px" %) |(% style="width:302px" %) a signal indicating that charger is connected;|(% style="width:187px" %)Charge controller, Discharge controller|(% style="width:92px" %)•|(% style="width:268px" %)• (if corresponding External equipment is online)|(% style="width:65px" %)
16 +|(% style="width:131px" %)Power up/down request |(% style="width:43px" %) |(% style="width:302px" %) a request to power down the device;|(% style="width:187px" %)Power down controller|(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
17 +|(% style="width:131px" %)Inhibit charging |(% style="width:43px" %) |(% style="width:302px" %) a command to open the charging contactor;|(% style="width:187px" %) |(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
18 +|(% style="width:131px" %)Inhibit discharging |(% style="width:43px" %) |(% style="width:302px" %) a command to open the discharging contactor;|(% style="width:187px" %) |(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
19 +|(% style="width:131px" %)CH contactor feedback |(% style="width:43px" %) |(% style="width:302px" %) a signal from charging contactor feedback loop;|(% style="width:187px" %)Contactor feedback protection|(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
20 +|(% style="width:131px" %)DCH contactor feedback |(% style="width:43px" %) |(% style="width:302px" %) a signal from discharging contactor feedback loop;|(% style="width:187px" %)Contactor feedback protection|(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
21 +|(% style="width:131px" %)Insulation status |(% style="width:43px" %) |(% style="width:302px" %) a signal from an insulation monitoring device;|(% style="width:187px" %)Insulation protection|(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
22 +|(% style="width:131px" %)Charge request |(% style="width:43px" %) |(% style="width:302px" %) a request to close the charging contactor;|(% style="width:187px" %)Charge controller|(% style="width:92px" %)•|(% style="width:268px" %)• (by request)|(% style="width:65px" %)
23 +|(% style="width:131px" %)Discharge request |(% style="width:43px" %) |(% style="width:302px" %) a request to close the discharging contactor;|(% style="width:187px" %)Discharge controller|(% style="width:92px" %)•|(% style="width:268px" %)• (by request)|(% style="width:65px" %)
24 +|(% style="width:131px" %)PCH contactor feedback |(% style="width:43px" %) |(% style="width:302px" %) a signal from precharging contactor feedback loop;|(% style="width:187px" %)Contactor feedback protection|(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
25 +|(% style="width:131px" %)CH/DCH contactor feedback |(% style="width:43px" %) |(% style="width:302px" %) a signal from charging/discharging contactor feedback loop;|(% style="width:187px" %)Contactor feedback protection|(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
26 +|(% style="width:131px" %)Main contactor feedback |(% style="width:43px" %) |(% style="width:302px" %) a signal from main contactor feedback loop;|(% style="width:187px" %)Contactor feedback protection|(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
27 +|(% style="width:131px" %)Interlock |(% style="width:43px" %) |(% style="width:302px" %) a signal from interlock loop;|(% style="width:187px" %)Interlock protection|(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
28 +|(% style="width:131px" %)Fuse 1, Fuse 2, Fuse 3 |(% style="width:43px" %) |(% style="width:302px" %) signals from fuses;|(% style="width:187px" %) |(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
29 +|(% style="width:131px" %)Circuit breaker status |(% style="width:43px" %) |(% style="width:302px" %) status of protection disconnector;|(% style="width:187px" %) |(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
30 +|(% style="width:131px" %)Balancing request |(% style="width:43px" %) |(% style="width:302px" %) a request to balance the cells;|(% style="width:187px" %)Cell balance controller|(% style="width:92px" %)•|(% style="width:268px" %)•|(% style="width:65px" %)
31 +|(% style="width:131px" %)Close Main contactor |(% style="width:43px" %) |(% style="width:302px" %) a request to close the main contactor;|(% style="width:187px" %)Main contactor controller|(% style="width:92px" %)•|(% style="width:268px" %)• (by request)|(% style="width:65px" %)
32 +|(% style="width:131px" %)Close External 1 |(% style="width:43px" %) |(% style="width:302px" %) a request to close the External 1 discrete output (if assigned).|(% style="width:187px" %)External 1 internal state|(% style="width:92px" %)•|(% style="width:268px" %) |(% style="width:65px" %)
33 33  
34 34  === List of internal states ===
35 35  
... ... @@ -66,20 +66,20 @@
66 66  
67 67  (% style="width:1177px" %)
68 68  |(% style="width:171px" %)**Name **|(% style="width:67px" %)**Abbr.**|(% style="width:501px" %)**Description**|(% style="width:228px" %)**Set up by**|(% style="width:145px" %)**Is a Critical error?**|(% style="width:145px" %)
69 -|(% style="width:171px" %)Overcurrent|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)Overcurrent protection|(% style="width:145px" %) |(% style="width:145px" %)
70 -|(% style="width:171px" %)Undervoltage|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)Undervoltage protection|(% style="width:145px" %) |(% style="width:145px" %)
71 -|(% style="width:171px" %)Overvoltage|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)Overvoltage protection|(% style="width:145px" %) |(% style="width:145px" %)
72 -|(% style="width:171px" %)Low temperature (DCH) |(% style="width:67px" %) |(% style="width:501px" %) temperature is too low for discharging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
73 -|(% style="width:171px" %)High temperature (DCH) |(% style="width:67px" %) |(% style="width:501px" %) temperature is too high for discharging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
74 -|(% style="width:171px" %)Battery cover error |(% style="width:67px" %) |(% style="width:501px" %) battery cover is open;|(% style="width:228px" %)Battery cover protection|(% style="width:145px" %)Yes|(% style="width:145px" %)
75 -|(% style="width:171px" %)High humidity |(% style="width:67px" %) |(% style="width:501px" %) humidity of the battery is increased;|(% style="width:228px" %)High humidity protection|(% style="width:145px" %) |(% style="width:145px" %)
76 -|(% style="width:171px" %)Water |(% style="width:67px" %) |(% style="width:501px" %) there is water in the battery enclosure;|(% style="width:228px" %)Water protection|(% style="width:145px" %)Yes|(% style="width:145px" %)
77 -|(% style="width:171px" %)High Logic temperature |(% style="width:67px" %) |(% style="width:501px" %) at least one of the Logic devices is overheated;|(% style="width:228px" %)Logic high temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
78 -|(% style="width:171px" %)Logic offline |(% style="width:67px" %) |(% style="width:501px" %) at least one of the Logic devices is offline;|(% style="width:228px" %)Logic offline protection|(% style="width:145px" %)Yes|(% style="width:145px" %)
79 -|(% style="width:171px" %)Critical error|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)Critical error|(% style="width:145px" %) |(% style="width:145px" %)
80 -|(% style="width:171px" %)Crown error |(% style="width:67px" %) |(% style="width:501px" %) connection with a Crown forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
81 -|(% style="width:171px" %)Cell count error |(% style="width:67px" %) |(% style="width:501px" %) number of cells does not match the specified value;|(% style="width:228px" %)Cell count protection|(% style="width:145px" %)Yes|(% style="width:145px" %)
82 -|(% style="width:171px" %)HYG offline |(% style="width:67px" %) |(% style="width:501px" %) connection with a HYG forklift is lost;|(% style="width:228px" %)HYG Class I-III truck|(% style="width:145px" %) |(% style="width:145px" %)
69 +|(% style="width:171px" %)Overcurrent|(% style="width:67px" %)OC|(% style="width:501px" %) |(% style="width:228px" %)Overcurrent protection|(% style="width:145px" %) |(% style="width:145px" %)
70 +|(% style="width:171px" %)Undervoltage|(% style="width:67px" %)UV|(% style="width:501px" %) |(% style="width:228px" %)Undervoltage protection|(% style="width:145px" %) |(% style="width:145px" %)
71 +|(% style="width:171px" %)Overvoltage|(% style="width:67px" %)OV|(% style="width:501px" %) |(% style="width:228px" %)Overvoltage protection|(% style="width:145px" %) |(% style="width:145px" %)
72 +|(% style="width:171px" %)Low temperature (DCH) |(% style="width:67px" %)LDT|(% style="width:501px" %) temperature is too low for discharging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
73 +|(% style="width:171px" %)High temperature (DCH) |(% style="width:67px" %)HDT|(% style="width:501px" %) temperature is too high for discharging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
74 +|(% style="width:171px" %)Battery cover error |(% style="width:67px" %)BC|(% style="width:501px" %) battery cover is open;|(% style="width:228px" %)Battery cover protection|(% style="width:145px" %)Yes|(% style="width:145px" %)
75 +|(% style="width:171px" %)High humidity |(% style="width:67px" %)HH|(% style="width:501px" %) humidity of the battery is increased;|(% style="width:228px" %)High humidity protection|(% style="width:145px" %) |(% style="width:145px" %)
76 +|(% style="width:171px" %)Water |(% style="width:67px" %)WA|(% style="width:501px" %) there is water in the battery enclosure;|(% style="width:228px" %)Water protection|(% style="width:145px" %)Yes|(% style="width:145px" %)
77 +|(% style="width:171px" %)High Logic temperature |(% style="width:67px" %)LHT|(% style="width:501px" %) at least one of the Logic devices is overheated;|(% style="width:228px" %)Logic high temperature protection|(% style="width:145px" %) |(% style="width:145px" %)
78 +|(% style="width:171px" %)Logic offline |(% style="width:67px" %)LOF|(% style="width:501px" %) at least one of the Logic devices is offline;|(% style="width:228px" %)Logic offline protection|(% style="width:145px" %)Yes|(% style="width:145px" %)
79 +|(% style="width:171px" %)Critical error|(% style="width:67px" %)CRE|(% style="width:501px" %) |(% style="width:228px" %)Critical error|(% style="width:145px" %) |(% style="width:145px" %)
80 +|(% style="width:171px" %)Crown error |(% style="width:67px" %)CRO|(% style="width:501px" %) connection with a Crown forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %)
81 +|(% style="width:171px" %)Cell count error |(% style="width:67px" %)CEL|(% style="width:501px" %) number of cells does not match the specified value;|(% style="width:228px" %)Cell count protection|(% style="width:145px" %)Yes|(% style="width:145px" %)
82 +|(% style="width:171px" %)HYG offline |(% style="width:67px" %)HYG|(% style="width:501px" %) connection with a HYG forklift is lost;|(% style="width:228px" %)HYG Class I-III truck|(% style="width:145px" %) |(% style="width:145px" %)
83 83  |(% style="width:171px" %)Need acknowledge |(% style="width:67px" %) |(% style="width:501px" %) there is an unacknowledged error in Error journal;|(% style="width:228px" %)Error journal|(% style="width:145px" %) |(% style="width:145px" %)
84 84  |(% style="width:171px" %)Combilift offline |(% style="width:67px" %) |(% style="width:501px" %) connection with a Combilift forklift is lost;|(% style="width:228px" %)Combilift truck|(% style="width:145px" %) |(% style="width:145px" %)
85 85  |(% style="width:171px" %)Short circuit|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)Short circuit protection|(% style="width:145px" %) |(% style="width:145px" %)