Changes for page 1. Battery controllers: signals and errors
Last modified by Admin on 2025/03/03 15:20
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -66,16 +66,16 @@ 66 66 67 67 (% style="width:1177px" %) 68 68 |(% style="width:171px" %)**Name **|(% style="width:67px" %)**Abbr.**|(% style="width:501px" %)**Description**|(% style="width:228px" %)**Set up by**|(% style="width:145px" %)**Is a Critical error?**|(% style="width:145px" %) 69 -|(% style="width:171px" %)Overcurrent|(% style="width:67px" %) 70 -|(% style="width:171px" %)Undervoltage|(% style="width:67px" %) 71 -|(% style="width:171px" %)Overvoltage|(% style="width:67px" %) 72 -|(% style="width:171px" %)Low temperature (DCH) |(% style="width:67px" %) 73 -|(% style="width:171px" %)High temperature (DCH) |(% style="width:67px" %) 74 -|(% style="width:171px" %)Battery cover error |(% style="width:67px" %) 75 -|(% style="width:171px" %)High humidity |(% style="width:67px" %) 76 -|(% style="width:171px" %)Water |(% style="width:67px" %) 77 -|(% style="width:171px" %)High Logic temperature |(% style="width:67px" %) 78 -|(% style="width:171px" %)Logic offline |(% style="width:67px" %) 69 +|(% style="width:171px" %)Overcurrent|(% style="width:67px" %)OC|(% style="width:501px" %) |(% style="width:228px" %)Overcurrent protection|(% style="width:145px" %) |(% style="width:145px" %) 70 +|(% style="width:171px" %)Undervoltage|(% style="width:67px" %)UV|(% style="width:501px" %) |(% style="width:228px" %)Undervoltage protection|(% style="width:145px" %) |(% style="width:145px" %) 71 +|(% style="width:171px" %)Overvoltage|(% style="width:67px" %)OV|(% style="width:501px" %) |(% style="width:228px" %)Overvoltage protection|(% style="width:145px" %) |(% style="width:145px" %) 72 +|(% style="width:171px" %)Low temperature (DCH) |(% style="width:67px" %)LDT|(% style="width:501px" %) temperature is too low for discharging;|(% style="width:228px" %)Low temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 73 +|(% style="width:171px" %)High temperature (DCH) |(% style="width:67px" %)HDT|(% style="width:501px" %) temperature is too high for discharging;|(% style="width:228px" %)High temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 74 +|(% style="width:171px" %)Battery cover error |(% style="width:67px" %)BC|(% style="width:501px" %) battery cover is open;|(% style="width:228px" %)Battery cover protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 75 +|(% style="width:171px" %)High humidity |(% style="width:67px" %)HH|(% style="width:501px" %) humidity of the battery is increased;|(% style="width:228px" %)High humidity protection|(% style="width:145px" %) |(% style="width:145px" %) 76 +|(% style="width:171px" %)Water |(% style="width:67px" %)WA|(% style="width:501px" %) there is water in the battery enclosure;|(% style="width:228px" %)Water protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 77 +|(% style="width:171px" %)High Logic temperature |(% style="width:67px" %)LHT|(% style="width:501px" %) at least one of the Logic devices is overheated;|(% style="width:228px" %)Logic high temperature protection|(% style="width:145px" %) |(% style="width:145px" %) 78 +|(% style="width:171px" %)Logic offline |(% style="width:67px" %)LOF|(% style="width:501px" %) at least one of the Logic devices is offline;|(% style="width:228px" %)Logic offline protection|(% style="width:145px" %)Yes|(% style="width:145px" %) 79 79 |(% style="width:171px" %)Critical error|(% style="width:67px" %) |(% style="width:501px" %) |(% style="width:228px" %)Critical error|(% style="width:145px" %) |(% style="width:145px" %) 80 80 |(% style="width:171px" %)Crown error |(% style="width:67px" %) |(% style="width:501px" %) connection with a Crown forklift is lost;|(% style="width:228px" %) |(% style="width:145px" %) |(% style="width:145px" %) 81 81 |(% style="width:171px" %)Cell count error |(% style="width:67px" %) |(% style="width:501px" %) number of cells does not match the specified value;|(% style="width:228px" %)Cell count protection|(% style="width:145px" %)Yes|(% style="width:145px" %)